Laserfiche WebLink
Printed on:Friday 10/13/2023 04:20 PM 29C0069/AAAN/115702Pageof4 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />9 <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition State <br />DECK ELEMENT INSPECTION RATINGS AND NOTES <br />Defect/ <br />Prot Defect <br />(38-1080) Delamination/Spall/Patched Area <br />(38-1130) Cracking (RC and Other) <br />(38-510-3210) Delam./Pothole-AC (WS) <br />(38-510-3220) Cracking-AC (WS) <br />(38-510-3230) Effectiveness (WS) <br />There is a six inch diameter soffit edge spall with an exposed rusted rebar near Bent 4 (see Photo 9 from BIR 09/02/2021). <br />There are up to 0.05 inch wide transverse deck cracks especially at the bents that can be seen where the deck wearing surface is <br />worn off (see Photos 8 and 9). <br />There are full depth AC overlay potholes near Abutment 6 right side (see Photo 10). <br />There are up to 0.5 inch wide tranverse AC cracks over the supports (see Photo 11). <br />Approximately 60% of the deck wearing surface has been worn off (see Photo 12). <br />(58) 7DECK RATING =