Laserfiche WebLink
Printed on:Tuesday 11/28/2023 08:06 AM 29C0071/AAAN/114843Pageof5 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />6 <br />JOINT/APPR/RAIL WORK RECOMMENDATIONS - NONE <br />SUPERSTRUCTURE WORK RECOMMENDATIONS - NONE <br />SUBSTRUCTURE WORK RECOMMENDATIONS - NONE <br />Photo 5 <br />Water Level (UAS, from right side) <br />Photo 6 <br />Approach AC Cracks (near Abutment 1) <br />Photo 7 <br />Approach AC Cracks (near Abutment 3) <br />OTHER PHOTOGRAPHS <br />DECK WORK RECOMMENDATIONS - NONE <br />205 <br />215 <br />Column-RC <br />Abrasion (PS Conc./RC) <br />Abutment-RC <br />Abrasion (PS Conc./RC) <br />2 <br />2 <br />2 <br />2 <br />5 <br />5 <br />22 <br />22 <br />each <br />each <br />m <br />each <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 5 <br /> 5 <br /> 22 <br /> 22 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br />SUBSTRUCTURE ELEMENT INSPECTION RATINGS AND NOTES <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br />1190 <br />1190 <br />SUBSTRUCTURE <br />SUBSTRUCTURE RATING =(60)(6) <br />WORK RECOMMENDATIONS <br />(205-1190) Abrasion (PS Conc./RC) <br />(215-1190) Abrasion (PS Conc./RC) <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition StateDefect/ <br />Prot Defect <br />From the 09/02/2021 BIR: There is mild abrasion with some exposed secure coarse aggregate on the columns in Bent 2 (see Photo <br />12). <br />From the 09/02/2021 BIR: There is up to three feet of abrasion with exposed secure course aggregate along both abutments (see <br />Photo 13).