Laserfiche WebLink
Printed on:Wednesday 08/18/2021 02:40 PM 29C0106/AAAI/70900Pageof6 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />7 <br />Photo 4 <br />Pier 3 exposed footing <br />SUBSTRUCTURE PHOTOGRAPHS <br />JOINT/APPR/RAIL WORK RECOMMENDATIONS - NONE <br />SUPERSTRUCTURE WORK RECOMMENDATIONS - NONE <br />SUBSTRUCTURE WORK RECOMMENDATIONS <br />Photo 1 <br />North is at the top of the page <br />OTHER PHOTOGRAPHS <br />DECK WORK RECOMMENDATIONS - NONE <br />234 <br />252 <br />Pier Cap-RC <br />Pile-CIDH <br />2 <br />2 <br />20 <br />1 <br />m <br />ea. <br /> 20 <br /> 1 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br />SUBSTRUCTURE ELEMENT INSPECTION RATINGS AND NOTES <br /> 0 <br /> 0 <br />SUBSTRUCTURE <br />SUBSTRUCTURE RATING =(60)7 <br />WORK RECOMMENDATIONS <br />(220-6000) Scour <br />(234) Pier Cap-RC <br />(252) Pile-CIDH <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition StateDefect/ <br />Prot Defect <br />The footing is exposed up to 20 inches vertically at Pier 3. No undermining was observed. See Photo 4. <br />There were no significant defects noted. <br />The pile element is included to indicate the presence of piles on this structure. The piles were not exposed for visual <br />inspection. No indication of pile distress was noted in any substructure element.