Laserfiche WebLink
Printed on:Tuesday 05/28/2024 04:06 PM 29C0225/AAAO/128907Pageof4 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />7 <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition State <br />DECK ELEMENT INSPECTION RATINGS AND NOTES <br />Defect/ <br />Prot Defect <br />(38-1080) Delamination/Spall/Patched Area <br />(38-1120) Efflorescence/Rust Staining <br />(38-510) Deck Wearing Surface-Asphalt <br />There is a spall in the soffit with exposed rebar in the left soffit in Span 2. <br />Refer to Photos 1 through 4 for the post repaired condition. <br />There are hairline longitudinal cracks with efflorescence along the centerline of the bridge in both spans. <br />There are several 0.2 inch wide longitudinal and transverse cracks in the AC overlay that was sealed with tar. Some smaller cracks <br />are starting to present themelves, but do not warrant a defect at this time. Refer to Photo 5. <br />(58) 7DECK RATING =