Laserfiche WebLink
Printed on:Sunday 03/03/2024 06:13 AM 29C0256/AAAN/121971Pageof3 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />6 <br />UNDERWATER INVESTIGATION DETAILS - NOT APPLICABLE FOR THIS BRIDGE. <br />STEEL INVESTIGATION DETAILS <br />SCOPE AND ACCESS <br />There was up to eighteen inches of water in Span 2 during the time of this inspection (Bent 3 was submerged). A complete routine <br />inspection was performed with the use of waders. <br />MISCELLANEOUS <br />The incorrect bridge identification (29C0258) is painted on the bridge rails. <br />WATERWAY <br />A channel cross section was taken during this inspection and is included in this report. A comparison was made with the previous cross <br />section taken on 03/03/2014. There has been no significant change. <br />INSPECTION COMMENTARY <br />TYPE OF MEMBRANE <br />TYPE OF DECK PROTECTION <br />DECK STRUCTURE TYPE <br />TYPE OF WEARING SURFACE <br />WEARING SURFACE / PROTECTIVE SYSTEM <br />1270AVERAGE DAILY TRAFFIC <br />2013 YEAR OF ADT <br />5 KMBYPASS, DETOUR LENGTH <br />20 %(109) TRUCK ADT % <br />4684FUTURE ADT <br />2046YEAR OF FUTURE ADT <br />HISTORICAL SIGNIFICANCE 5: NOT ELIGIBLE FOR NRHP <br />6-BITUMINOUS <br />0-NONE <br />0-NONE <br />1-CIP CONCRETE <br />DECK STRUCTURE INFORMATION <br />10.0 M <br />9.8 M <br />DECK AND ROADWAY <br />LANES 2 <br />55 <br />0-NOT ON NHS <br />PARALLEL STRUCTURE <br />TEMPORARY STRUCTURE <br />DEFENSE HIGHWAY <br />FUNCTIONAL CLASS <br />SPEED <br />NATIONAL HIGHWAY SYSTEM <br />TOLL <br />DIRECTION OF TRAFFIC <br />DESIGNATED NATIONAL NETWORK <br />TYPE OF SERVICE <br />FEDERAL LANDS HWY <br />8 EQUAL DESIRABLE CRITAPPR ROADWAY ALIGN <br />5 ABOVE TOLERABLEDECK GEOMETRY <br />9.8 MAPPROACH RDWY WIDTH <br />BRIDGE MEDIAN <br />LEFT 0.0 M RIGHT 0.0 MCURB OR SIDEWALK <br />TOTAL WIDTH <br />NET WIDTH <br />9.8 MINVENTORY ROUTE TOTAL HORIZ CLEAR <br />99.99 MINVENTORY ROUTE MIN VERT CLEAR <br />3-ON FREE ROAD <br />08-MINOR COLLECTOR RURAL <br />0-NOT STRAHNET <br />N-NONE EXISTS <br />2-2 WAY <br />0-NOT APPLICABLE <br />0-NOT ON NET <br />0 NO MEDIAN <br />1-HIGHWAY <br />DECK ROADWAY/OPERATIONAL INFORMATIONDECK GEOMETRY <br />0.3 ft br, 32.2 ft, 0.3 ft br <br />DECK CROSS SECTION <br />LRS INVENTORY RTE & SUBRTE <br />BASE HIGHWAY NETWORK 0-NOT ON NET <br />- NOT APPLICABLE FOR THIS BRIDGE. <br />.5 inchesOVERLAY THICKNESS (inches) <br />N/A <br />(51) <br />(52) <br />(50) <br />(32) <br />(33) <br />(107) <br />(108) <br />A) <br />B) <br />C) <br />(29) <br />(30) <br />(19) <br />(114) <br />(115) <br />(37) <br />(42a) <br />(12) <br />(13) <br />(104) <br />(26) <br />(100) <br />(101) <br />(102) <br />(10) <br />(47) <br />(68) <br />(72) <br />(105) <br />(110) <br />(20) <br />(28a) <br />(103) <br />CONDITION INFORMATION <br />37.4 MLENGTH (49) <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition State <br />38 Slab-RC <br />Cracking (RC and Other) <br />Deck Wearing Surface-Asphalt <br />Effectiveness (WS) <br />2 <br />2 <br />2 <br />2 <br />372 <br />100 <br />259 <br />155 <br />sq.m <br />each <br />sq.m <br />each <br /> 272 <br /> 0 <br /> 104 <br /> 0 <br /> 100 <br /> 100 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 155 <br /> 155 <br />DECK ELEMENT INSPECTION RATINGS AND NOTES <br />Defect/ <br />Prot <br />1130 <br />510 <br />Defect <br />3230 <br />(38-1130) Cracking (RC and Other) <br />There are up to 0.05 inch wide transverse cracks throughout the deck (see Photo 5). The cracks are mostly in Spans 3 and 4 <br />(concentrated over Bents 3 and 4) and along Abutment 1. There are up to 0.02 inch wide random transverse and longitudinal soffit <br />cracks in Spans 3 and 4 (see Photo 6). <br />(58) (6)DECK RATING = <br />SPECIAL INSPECTION INFORMATION