Laserfiche WebLink
Printed on:Sunday 03/03/2024 06:26 AM 29C0288/AAAN/121969Pageof3 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />6 <br />UNDERWATER INVESTIGATION DETAILS - NOT APPLICABLE FOR THIS BRIDGE. <br />STEEL INVESTIGATION DETAILS <br />SCOPE AND ACCESS <br />There was approximately two and a half feet of water in the creek during the time of this inspection with Bent 2 submerged. A complete <br />routine inspection was performed with the use of waders and a probe stick. <br />DECK AND ROADWAY <br />There are sealed cracks in the approach AC near both abutments (see Photos 5 and 6). There is differential settlement of the approach <br />AC. <br />INSPECTION COMMENTARY <br />TYPE OF MEMBRANE <br />TYPE OF DECK PROTECTION <br />DECK STRUCTURE TYPE <br />TYPE OF WEARING SURFACE <br />WEARING SURFACE / PROTECTIVE SYSTEM <br />117AVERAGE DAILY TRAFFIC <br />2013 YEAR OF ADT <br />10 KMBYPASS, DETOUR LENGTH <br />20 %(109) TRUCK ADT % <br />132FUTURE ADT <br />2046 YEAR OF FUTURE ADT <br />HISTORICAL SIGNIFICANCE 5: NOT ELIGIBLE FOR NRHP <br />0-NONE <br />0-NONE <br />0-NONE <br />1-CIP CONCRETE <br />DECK STRUCTURE INFORMATION <br />8.7 M <br />8.5 M <br />DECK AND ROADWAY <br />LANES 2 <br />45 <br />0-NOT ON NHS <br />PARALLEL STRUCTURE <br />TEMPORARY STRUCTURE <br />DEFENSE HIGHWAY <br />FUNCTIONAL CLASS <br />SPEED <br />NATIONAL HIGHWAY SYSTEM <br />TOLL <br />DIRECTION OF TRAFFIC <br />DESIGNATED NATIONAL NETWORK <br />TYPE OF SERVICE <br />FEDERAL LANDS HWY <br />8 EQUAL DESIRABLE CRITAPPR ROADWAY ALIGN <br />6 EQUAL MIN CRITERIADECK GEOMETRY <br />5.8 MAPPROACH RDWY WIDTH <br />BRIDGE MEDIAN <br />LEFT 0.0 M RIGHT 0.0 MCURB OR SIDEWALK <br />TOTAL WIDTH <br />NET WIDTH <br />8.5 MINVENTORY ROUTE TOTAL HORIZ CLEAR <br />99.99 MINVENTORY ROUTE MIN VERT CLEAR <br />3-ON FREE ROAD <br />09-LOCAL RURAL <br />0-NOT STRAHNET <br />N-NONE EXISTS <br />2-2 WAY <br />0-NOT APPLICABLE <br />0-NOT ON NET <br />0 NO MEDIAN <br />1-HIGHWAY <br />DECK ROADWAY/OPERATIONAL INFORMATIONDECK GEOMETRY <br />0.3 ft br, 28.0 ft, 0.3 ft br <br />DECK CROSS SECTION <br />LRS INVENTORY RTE & SUBRTE <br />BASE HIGHWAY NETWORK 0-NOT ON NET <br />- NOT APPLICABLE FOR THIS BRIDGE. <br />0 inchesOVERLAY THICKNESS (inches) <br />N/A <br />(51) <br />(52) <br />(50) <br />(32) <br />(33) <br />(107) <br />(108) <br />A) <br />B) <br />C) <br />(29) <br />(30) <br />(19) <br />(114) <br />(115) <br />(37) <br />(42a) <br />(12) <br />(13) <br />(104) <br />(26) <br />(100) <br />(101) <br />(102) <br />(10) <br />(47) <br />(68) <br />(72) <br />(105) <br />(110) <br />(20) <br />(28a) <br />(103) <br />CONDITION INFORMATION <br />18.6 MLENGTH (49) <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition State <br />38 Slab-RC <br />Cracking (RC and Other) <br />2 <br />2 <br />160 <br />48 <br />sq.m <br />each <br /> 112 <br /> 0 <br /> 48 <br /> 48 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br />DECK ELEMENT INSPECTION RATINGS AND NOTES <br />Defect/ <br />Prot <br />1130 <br />Defect <br />(38-1130) Cracking (RC and Other) <br />There are up to 0.04 inch wide pattern deck cracks more concentrated at the bent and covering approximately 30% of the deck (see <br />Photo 7 BIR 01/19/2022). <br />(58) (6)DECK RATING = <br />SPECIAL INSPECTION INFORMATION <br />(36a) Rail Code 0010 <br />JOINT/APPROACH/RAIL ELEMENT INSPECTION RATINGS AND NOTES <br />RAIL INFORMATION <br />(36b) Transition (36c) Appr Guardrail (36d) Appr Guardrail End 45Roadway Speed MPH <br />JOINT - APPROACH - RAIL <br />Element DescriptionElem Env Total Units Qty in each Condition StateDefect/