Laserfiche WebLink
Printed on:Friday 10/13/2023 03:59 PM 29C0333/AAAN/114742Pageof1 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />5 <br /> Routine-Roadway View (09/02/2021) Routine-Elevation View (09/02/2021) <br /> Routine-Underside View (09/02/2021) Routine-Map View (08/11/2021) <br />PHOTOGRAPH IDENTIFICATION <br />0.7 MI E ALPINE RDLOCATION <br />TEAM LEADER Kristina J. Shurbert <br />FACILITY CARRIED LIVE OAK RD <br />No. <br />REPORT AUTHOR Kristina J. Shurbert <br />FEATURE INTERSECTED BEAR CREEK <br />BRIDGE LOCATION INFORMATION <br /> 38°04'46.87"LATITUDE <br />Kristina J. Shurbert (Registered Civil Engineer) <br />INSPECTED BY KJ.Shurbert/M.Molina Bed <br />N N/A (NBI)CULVERT <br />7 GOODDECK <br />(6 SATISFACTORY)SUBSTRUCTURE <br />7 GOODSUPERSTRUCTURE 97.8SUFFICIENCY RATING <br />STRUCTURALLY DEFICIENT (SD) STATUS NOT SD <br /> 491 <br />PAINT CONDITION N/A <br />STRUCTURAL HEALTH CONDITION SUMMARY INFORMATION <br />6 EQUAL MIN CRITERIASTRUCTURE EVALUATION <br />121°12'04.7"LONGITUDE <br />5 STABLE W/IN FOOTING OR PILSCOUR <br />INVENTORY RTE(ON/UNDER)140000000ON <br />POSTMILE 0 <br />ON NATIONAL HIGHWAY SYSTEM NOT ON NHS <br />(9) <br />(11) <br />(16) <br />(17) <br />(7) <br />(6) <br />(5) <br />(104) <br />(58) <br />(59) <br />(60) <br />(62) <br />(67) (113) <br />Routine Inspection <br />BRIDGE INSPECTION REPORT <br />Kristina J. <br />Shurbert <br />12/31/2023 <br />CIVIL <br />47440 <br />10/13/2023 <br />Date <br />Exp. <br />BRIDGE NO.: <br />29C0333 <br />STRUCTURE NAME: <br />BEAR CREEK September 18, 2023 <br />INSPECTION DATE: <br />DECK AREA (M) 2