Laserfiche WebLink
Printed on:Monday 04/07/2025 01:03 PM 29C0345/AAAO/149692Pageof3 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />5 <br />UNDERWATER INVESTIGATION DETAILS - NOT APPLICABLE FOR THIS BRIDGE. <br />STEEL INVESTIGATION DETAILS <br />SCOPE AND ACCESS <br />This follow up inspection was performed to inspect the lower portions of the columns and measure the channel cross section due to high <br />velocity flow and water level during the last routine inspection in 2023. During this follow-up inspection there was 2 feet of water in the <br />creek below Span 2. Pier 2 was submerged and inspected with the aid of probing and Pier 3 was at the waterline and inspected through <br />shallow water. A complete follow-up inspection was performed. <br />INSPECTION COMMENTARY <br />TYPE OF MEMBRANE <br />TYPE OF DECK PROTECTION <br />DECK STRUCTURE TYPE <br />TYPE OF WEARING SURFACE <br />WEARING SURFACE / PROTECTIVE SYSTEM <br />301AVERAGE DAILY TRAFFIC <br />2013 YEAR OF ADT <br />11 KMBYPASS, DETOUR LENGTH <br />5 %(109) TRUCK ADT % <br />272FUTURE ADT <br />2041 YEAR OF FUTURE ADT <br />HISTORICAL SIGNIFICANCE 5: NOT ELIGIBLE FOR NRHP <br />6-BITUMINOUS <br />0-NONE <br />0-NONE <br />1-CIP CONCRETE <br />DECK STRUCTURE INFORMATION <br />9.9 M <br />9.7 M <br />DECK AND ROADWAY <br />LANES 2 <br />55 <br />0-NOT ON NHS <br />PARALLEL STRUCTURE <br />TEMPORARY STRUCTURE <br />DEFENSE HIGHWAY <br />FUNCTIONAL CLASS <br />SPEED <br />NATIONAL HIGHWAY SYSTEM <br />TOLL <br />DIRECTION OF TRAFFIC <br />DESIGNATED NATIONAL NETWORK <br />TYPE OF SERVICE <br />FEDERAL LANDS HWY <br />8 EQUAL DESIRABLE CRITAPPR ROADWAY ALIGN <br />6 EQUAL MIN CRITERIADECK GEOMETRY <br />9.7 MAPPROACH RDWY WIDTH <br />BRIDGE MEDIAN <br />LEFT 0.0 M RIGHT 0.0 MCURB OR SIDEWALK <br />TOTAL WIDTH <br />NET WIDTH <br />9.7 MINVENTORY ROUTE TOTAL HORIZ CLEAR <br />99.99 MINVENTORY ROUTE MIN VERT CLEAR <br />3-ON FREE ROAD <br />09-LOCAL RURAL <br />0-NOT STRAHNET <br />N-NONE EXISTS <br />2-2 WAY <br />0-NOT APPLICABLE <br />0-NOT ON NET <br />0 NO MEDIAN <br />1-HIGHWAY <br />DECK ROADWAY/OPERATIONAL INFORMATIONDECK GEOMETRY <br />0.29 feet br, 32.00 feet, 0.33 feet br <br />DECK CROSS SECTION <br />LRS INVENTORY RTE & SUBRTE <br />BASE HIGHWAY NETWORK 0-NOT ON NET <br />- NOT APPLICABLE FOR THIS BRIDGE. <br />1 inchesOVERLAY THICKNESS (inches) <br />N/A <br />(51) <br />(52) <br />(50) <br />(32) <br />(33) <br />(107) <br />(108) <br />A) <br />B) <br />C) <br />(29) <br />(30) <br />(19) <br />(114) <br />(115) <br />(37) <br />(42a) <br />(12) <br />(13) <br />(104) <br />(26) <br />(100) <br />(101) <br />(102) <br />(10) <br />(47) <br />(68) <br />(72) <br />(105) <br />(110) <br />(20) <br />(28a) <br />(103) <br />CONDITION INFORMATION <br />22.2 MLENGTH (49) <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition State <br />38 Slab-RC <br />Cracking (RC and Other) <br />Deck Wearing Surface-Asphalt <br />2 <br />2 <br />2 <br />220 <br />44 <br />162 <br />sq.m <br />each <br />sq.m <br /> 176 <br /> 0 <br /> 162 <br /> 44 <br /> 44 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br />DECK ELEMENT INSPECTION RATINGS AND NOTES <br />Defect/ <br />Prot <br />1130 <br />510 <br />Defect <br />(38) Slab-RC <br />(38-1130) Cracking (RC and Other) <br />This condition was not inspected during this investigation. <br />There is AC overlay present throughout the RC slab surface except for sections 12 to 18 inches wide at the edges of the RC slab. <br />This condition was not inspected during this investigation. <br />There are longitudinal and transverse cracks up to 0.03 inches wide spaced 1 to 3 feet on center in the soffit of the RC slab. The <br />more severe cracks are longitudinal in direction and are located within a section 6 feet wide along the centerline of the bridge. The <br />(58) 7DECK RATING = <br />SPECIAL INSPECTION INFORMATION