Printed on:Thursday 10/27/2022 03:31 PM 29C0383/AAAN/90690Pageof3 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />7 <br />UNDERWATER INVESTIGATION DETAILS <br />STEEL INVESTIGATION DETAILS <br />SCOPE AND ACCESS <br />The aqueduct was flowing full through all three spans at the time of this investigation. The abutments were outside of the concrete lining <br />and the superstructure and soffit of Spans 1 and 3 were inspected from the canal banks with the aid of binoculars. The soffit of Span 2 <br />was visually observed from the deck with the use of truck mirrors. <br />The submerged portions of Piers 2 and 3 were inspected by the Caltrans Underwater Inspection Team. The most recent underwater <br />investigation was performed on 02/13/2018. All identified defects from that inspection have been incorporated into the condition states of <br />the respective elements and have been described in the element or defect notes. Refer to the 02/13/2018 underwater inspection report <br />for further detail. <br />MISCELLANEOUS <br />A new routine map view photo was added during this investigation. See Photo 1. <br />DECK AND ROADWAY <br />The AC approach pavement near each abutment is cracked, beginning to pothole and heaving up to 2 inches near the deck surface. The <br />10/30/2000 work recommendation to repair and resurface the AC approach pavement near each abutment is still valid and should be <br />completed to prevent vehicle impact onto the bridge deck. See Photos 2 and 3. <br />INSPECTION COMMENTARY <br />TYPE OF MEMBRANE <br />TYPE OF DECK PROTECTION <br />DECK STRUCTURE TYPE <br />TYPE OF WEARING SURFACE <br />WEARING SURFACE / PROTECTIVE SYSTEM <br />1589AVERAGE DAILY TRAFFIC <br />2002 YEAR OF ADT <br />13 KMBYPASS, DETOUR LENGTH <br />5 %(109) TRUCK ADT % <br />2173FUTURE ADT <br />2040 YEAR OF FUTURE ADT <br />HISTORICAL SIGNIFICANCE 5: NOT ELIGIBLE FOR NRHP <br />0-NONE <br />0-NONE <br />0-NONE <br />1-CIP CONCRETE <br />DECK STRUCTURE INFORMATION <br />10.4 M <br />9.8 M <br />DECK AND ROADWAY <br />LANES 2 <br />55 <br />0-NOT ON NHS <br />PARALLEL STRUCTURE <br />TEMPORARY STRUCTURE <br />DEFENSE HIGHWAY <br />FUNCTIONAL CLASS <br />SPEED <br />NATIONAL HIGHWAY SYSTEM <br />TOLL <br />DIRECTION OF TRAFFIC <br />DESIGNATED NATIONAL NETWORK <br />TYPE OF SERVICE <br />FEDERAL LANDS HWY <br />8 EQUAL DESIRABLE CRITAPPR ROADWAY ALIGN <br />5 ABOVE TOLERABLEDECK GEOMETRY <br />9.8 MAPPROACH RDWY WIDTH <br />BRIDGE MEDIAN <br />LEFT 0.3 M RIGHT 0.3 MCURB OR SIDEWALK <br />TOTAL WIDTH <br />NET WIDTH <br />9.8 MINVENTORY ROUTE TOTAL HORIZ CLEAR <br />99.99 MINVENTORY ROUTE MIN VERT CLEAR <br />3-ON FREE ROAD <br />07-MAJOR COLLECTOR RURAL <br />0-NOT STRAHNET <br />N-NONE EXISTS <br />2-2 WAY <br />0-NOT APPLICABLE <br />0-NOT ON NET <br />0 NO MEDIAN <br />1-HIGHWAY <br />DECK ROADWAY/OPERATIONAL INFORMATIONDECK GEOMETRY <br />1 ft cu & br, 32 ft, 1 ft cu & br <br />DECK CROSS SECTION <br />LRS INVENTORY RTE & SUBRTE <br />BASE HIGHWAY NETWORK 0-NOT ON NET <br />1 - FreshWater TypeB - Routine UWDive Type <br />Next UWI 02/13/2024UWI Frequency months 72UWI Required Y Last UWI 02/13/2018 <br />- NOT APPLICABLE FOR THIS BRIDGE. <br />0 inchesOVERLAY THICKNESS (inches) <br />N/A <br />(51) <br />(52) <br />(50) <br />(32) <br />(33) <br />(107) <br />(108) <br />A) <br />B) <br />C) <br />(29) <br />(30) <br />(19) <br />(114) <br />(115) <br />(37) <br />(42a) <br />(12) <br />(13) <br />(104) <br />(26) <br />(100) <br />(101) <br />(102) <br />(10) <br />(47) <br />(68) <br />(72) <br />(105) <br />(110) <br />(20) <br />(28a) <br />(103) <br />CONDITION INFORMATION <br />63.7 MLENGTH (49) <br />DECK ELEMENT INSPECTION RATINGS AND NOTES (58) DECK RATING = <br />SPECIAL INSPECTION INFORMATION