Laserfiche WebLink
Printed on:Tuesday 08/22/2023 09:12 AM 29C0389/AAAL/111944Pageof5 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />6 <br />DESCRIPTION UNDER STRUCTURE <br />CHANNEL DESCRIPTION <br />Trapezoidal shape earth. <br />TYPE OF SERVICE UNDER <br />N NOT APPLICABLE (NBI)UNDERCLEARANCES V - H <br />8 EQUAL DESIRABLEWATER ADEQUACY <br /> MVERT-LIFT BRIDGE NAV MIN VERTICAL CLEAR <br />NAVIGATION CONTROL <br />0.0 MNAVIGATION HORIZONTAL CLEARANCE <br />0.0 MNAVIGATION VERTICAL CLEARANCE <br />PIER PROTECTION <br />0: NO CONTROL5-WATERWAY <br />8 STABLE ABOVE FOOTINGSCOUR <br />N/ASCOUR POA DATE <br />CHANNEL PROTECTION 7 MINOR DAMAGE <br />N/A <br />(42b) <br />(69) <br />(71) <br />(61) <br />(113) <br />(38) <br />(111) <br />(39) <br />(116) <br />(40) <br />241 Culvert-RC <br />Efflorescence/Rust Staining <br />Deck Wearing Surface-Asphalt <br />Cracking-AC (WS) <br />2 <br />2 <br />2 <br />2 <br />21 <br />4 <br />77 <br />14 <br />m <br />each <br />sq.m <br />each <br /> 21 <br /> 4 <br /> 63 <br /> 0 <br /> 0 <br /> 0 <br /> 14 <br /> 14 <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br />SUBSTRUCTURE ELEMENT INSPECTION RATINGS AND NOTES <br /> 0 <br /> 0 <br /> 0 <br /> 0 <br />1120 <br />510 <br />3220 <br />SUBSTRUCTURE <br />(62) CULVERT RATING = 7 <br />(241) Culvert-RC <br />(241-1120) Efflorescence/Rust Staining <br />(241-510-3220) Cracking-AC (WS) <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition StateDefect/ <br />Prot Defect <br />The extended culvert invert is exposed at both ends of the culvert as follows: <br />*Left / downstream side: 16 to 18 inches <br />*Right / upstream side: 4 to 6 inches <br />No undermining of the invert walls was evident. The exposure did not affect the culvert. (See Photos 13 and 14 dated 03/19/2019). <br />This condition has been previously reported and was confirmed with probing. <br />There are horizontal cracks present at the end wingwalls near the culvert. The cracks are less than 0.03 inches wide and spaced as <br />close as 1 to 4 feet on center and exhibited minor efflorescence or staining. (See Photos 15 to 18 dated 03/19/2019). This condition <br />has been previously reported and no significant changes were noted. <br />There are longitudinal and transverse cracks up to 0.01 inches wide with light efflorescence in the soffit of the top slab. This effects <br />approximately 5% of the soffit. (See Photos 20 and 21 dated 03/19/2019). This condition has been previously reported and no <br />significant changes were noted. <br />There is a depression over an area up to 15 feet long x 10 feet wide in the AC overlay in the southbound lane in Span 1. There are <br />longitudinal and transverse cracks up to 0.5 inches wide spaced up to 8 inches on center extending from the depression. See Photos <br />3 and 4. <br />There are longitudinal and transverse cracks up to 0.5 inches wide randomly spaced throughout the AC overlay. See Photo 4.