Laserfiche WebLink
Printed on:Monday 10/14/2024 12:40 PM 29C0393/AAAS/136929Pageof1 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />8 <br /> Routine-Roadway View (06/25/2018) Routine-Elevation View (06/25/2018) <br /> Routine-Underside View (06/25/2018) Routine-Map View (10/26/2022) <br />PHOTOGRAPH IDENTIFICATION <br />LWER SAC RD SAC/SJ CO LNLOCATION <br />TEAM LEADER Pamela Gagnier <br />FACILITY CARRIED LINCOLN WAY <br />No. <br />REPORT AUTHOR Pamela Gagnier <br />FEATURE INTERSECTED DRY CREEK <br />BRIDGE LOCATION INFORMATION <br /> 38°14'16.47"LATITUDE <br />Anthony Fernandes (Registered Civil Engineer) <br />INSPECTED BY P.Gagnier/K.Ballisty <br />N N/A (NBI)CULVERT <br />5 FAIRDECK <br />7 GOODSUBSTRUCTURE <br />5 FAIRSUPERSTRUCTURE 79.9SUFFICIENCY RATING <br />STRUCTURALLY DEFICIENT (SD) STATUS NOT SD <br /> 2,704 <br />PAINT CONDITION N/A <br />STRUCTURAL HEALTH CONDITION SUMMARY INFORMATION <br />5 ABOVE MIN TOLERABLESTRUCTURE EVALUATION <br />121°17'35.89"LONGITUDE <br />3 SC - UNSTABLESCOUR <br />INVENTORY RTE(ON/UNDER)150000000ON <br />POSTMILE 0 <br />ON NATIONAL HIGHWAY SYSTEM NOT ON NHS <br />(9) <br />(11) <br />(16) <br />(17) <br />(7) <br />(6) <br />(5) <br />(104) <br />(58) <br />(59) <br />(60) <br />(62) <br />(67) (113) <br />Routine Inspection <br />BRIDGE INSPECTION REPORT <br />Anthony <br />Fernandes <br />06/30/2026 <br />CIVIL <br />60501 <br />10/14/2024 <br />Date <br />Exp. <br />BRIDGE NO.: <br />29C0393 <br />STRUCTURE NAME: <br />DRY CREEK June 27, 2024 <br />INSPECTION DATE: <br />DECK AREA (M) 2