Laserfiche WebLink
Printed on:Wednesday 05/28/2025 06:29 AM 29C0108/AABF/149448Pageof2 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />11 <br />Main Spans (2): movable swing type constructed of welded plate girders (3) with a lightweight concrete deck. <br />Approach Spans (23): continuous CIP/RC slabs on multiple type column/pile extension bents and RC diaphragm abutments with <br />monolithic wingwalls. <br />Bents 6, 11, 16 and Piers 21, 22, and 23 are founded on CISS piles. All other bents are founded on PC/PS piles. <br />16 @ 30.0 ft, 3 @ 40.0 ft, 1 @ 30.0 ft, 2 @ 120.0 ft, 3 @ 35.0 ft <br />STRUCTURE DESCRIPTION <br />SPAN CONFIGURATION <br />(29)SAN JOAQUIN <br />10 <br />(00000) _____ <br />BORDER BRIDGE STRUCTURE NUMBER <br />BORDER BRIDGE STATE CODE <br />COUNTY CODE <br />HIGHWAY DISTRICT <br />STATE NAME <br />PLACE CODE <br />% SHARE <br />AGENCY INFORMATION <br />CONSTRUCTION INFORMATION <br />N/A <br />YEAR BUILT <br />YEAR MODIFIED <br />LENGTH (M) <br />JOINTS <br />1995 <br />SKEW <br />NO. OF HINGES <br />297.2 <br />0 <br />05 <br />MAIN SPANS <br />APPR SPANS 23 <br />2 <br />MAX SPAN (M)36.6 <br />STR FLARE 1-YES <br />NBIS BR LENGTH Y <br />STRUCTURE TYPE MAIN 3: STEEL <br />DESIGN TYPE MAIN 17: MOVABLE - SWING <br />STRUCTURE TYPE APPR 2: CONCRETE CONT <br />DESIGN TYPE APPR 01: SLAB <br />INSPECTION INFORMATION <br />CRITICAL FEATURE INSPECTION (93) CFI DATE <br />24 MO 04/23A)Y-YESNSTM INSP <br />MON-NOOTHER SPECIAL INSP C) <br />60 MOY-YESUNDERWATER INSP 08/24B) <br />INSPECTION DATE (91) FREQUENCY MO02/25 24 <br />MAINTAIN 02 COUNTY HWY AGENCY <br />OWNER 02 COUNTY HWY AGENCY <br />CALIFORNIA 069 <br />N/AN/A <br />N/A <br />N/A <br />(1) <br />(2) <br />(3) <br />(4) <br />(21) <br />(22) <br />(98) <br />(99) <br />(90) <br />(92) <br />A) <br />B) <br />C) <br />(27) <br />(106) <br />(34) <br />(49) <br />(112) <br />(45) <br />(46) <br />(48) <br />(35) <br />(43a) <br />(43b) <br />(44a) <br />(44b) <br /> STRUCTURE OVERVIEW <br />CHANNEL CONDITION RATING 9 Excellent <br />7 Good <br />7 Good <br />AB-T - Temporary <br />A) All routine permits allowed <br />E/E' details are present <br />(B.C.09) <br />CHANNEL PROTECTION RATING(B.C.10) <br />SCOUR CONDITION RATING(B.C.11) <br />NSTM CONDITION RATING(B.C.14) <br />UW CONDITION RATING(B.C.15) <br />SCOUR VULNERABILITY RATING(B.AP.03) <br />ROUTINE PERMIT LOADS(B.LR.08) <br />FATIGUE DETAILS(B.IR.02) <br />SNBI ITEMS USED TO CHECK INSPECTION FREQUENCY