Laserfiche WebLink
Printed on:Wednesday 05/07/2025 07:10 AM 29C0160/AAAP/148617Pageof3 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />7 <br />LOAD CAPACITY <br />DESIGN LOAD <br />INVENTORY RATING <br />OPERATING RATING <br />CALC METHOD <br />CALC METHOD <br />0 UNKNOWN <br />RF= 0.70 <br />RF= 0.91 <br />8 LRFR RATING FACTOR <br />8 LRFR RATING FACTOR <br />PERMIT RATING <br />POSTING LOADS <br />Legal <br />Type 3 <br />Type 3S2 <br />Type 3-3 <br />Legal <br />Legal <br />PPPPP <br />99.99 MUnimpaired <br />MINIMUM VERTICAL CLEARANCE MINIMUM LATERAL UNDERCLEARANCE <br />BRIDGE POSTING <br />STRUCTURE STATUS <br />0.0 M(56) MIN LAT UNDERCLEAR LT <br />0.0 M(55) MIN LAT UNDERCLEAR RT REF(53) MIN VERT CLEAR OVER BRIDGE RDWY <br />0.00 M(54) MIN VERT UNDERCLEAR REF <br />5 AT/ABOVE LEGAL LOADS <br />A-OPEN, NO RESTRICTION <br />N-NOT H/RR <br />N-NOT H/RR <br />Safe <br />Loads <br />N/A <br />N/A <br />N/A <br />Existing <br />Ordinance/Order <br />N/A <br />N/A <br />Posting <br />Signs <br />U.S. Tons <br />U.S. Tons <br />U.S. Tons <br />25Speed N/A N/A MPH <br /> <br /> <br />Additional Ordinance/Order Requirements <br />Additional Signs <br />Load Rating Summary Date <br />Load Rating Type <br />06/06/18 <br />Posting Date N/A <br />(31) <br />(66) <br />(64) <br />(41) <br />(65) <br />(63) <br />(70) <br />OPERATIONAL INFORMATION <br />OVERLAY THICKNESS 3 inches <br />Load Rating Tool - Date BrR 6.8.2 AASHTO - 06/05/18 <br />Calculated <br />N/A <br />NONE <br />NONE