Laserfiche WebLink
Printed on:Wednesday 04/30/2025 02:25 PM 29C0228/AAAO/151730Pageof4 <br />Department of Transportation - Division of Maintenance Structure Maintenance & Investigations <br />6 <br />Photo 2 <br />Tree removed between the steel pipe and the deck in Span 3. <br />Span 3 in background <br /> DECK PHOTOGRAPHS <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition State <br />DECK ELEMENT INSPECTION RATINGS AND NOTES <br />Defect/ <br />Prot Defect <br />(38) Slab-RC <br />(38-510-3220) Cracking-AC (WS) <br />There were no significant defects noted. <br />There are pattern and transverse cracks up to 0.125 inches wide randomly located throughout the AC overlay. This condition effects <br />approximately 10% of the element quantity. (See Photo 4 dated 02/16/2021). This condition has been previously reported and no <br />significant changes were noted. <br />(58) 7DECK RATING = <br />(36a) Rail Code 0000 <br />330 Railing-Metal 2 44 m 44 0 0 0 <br />JOINT/APPROACH/RAIL ELEMENT INSPECTION RATINGS AND NOTES <br />RAIL INFORMATION <br />(36b) Transition (36c) Appr Guardrail (36d) Appr Guardrail End 55Roadway Speed MPH <br />JOINT - APPROACH - RAIL <br />(330) Railing-Metal <br />Element DescriptionElem <br />No. <br />Env Total <br />Qty <br />Units <br />CS 1 CS 2 CS 3 CS 4 <br />Qty in each Condition StateDefect/ <br />Prot Defect <br />There is a scrap up to 5 feet long on the left metal bridge rail at Abutment 4. A defect is not warranted at this time. <br />There were no significant defects noted.