PW-ENCUTIL-2502334
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2025
>
PW-ENCUTIL-2502001 thru PW-ENCUTIL-2502500
>
PW-ENCUTIL-2502334
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/2/2025 3:55:47 PM
Creation date
7/2/2025 3:54:34 PM
Metadata
Fields
Template:
Permits_Development
DocName
PW-ENCUTIL-2502334
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2025
Location
1125 David Ave. to 3423 Guernsey Ave.
Type - Permit Process
Perform splicing at 5 locations for Comcast services
Address
12687 S. Manthey Rd., Lathrop,CA 95330
Application
Mastec Network Solutions Inc.
Project #
110005
Type
Utility Encroachment
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
UNETYPES <br />— — <br />— — — — — — — — — <br />— — <br />— — PROPOSED BORE ROUTE <br />— — <br />— — — — — — — — — <br />— — <br />— — PROPOSED TRENCH ROUTE <br />CATY <br />NEW AERIAL ROUTE <br />TV <br />OVERPULL/EXISTING COMCAST CONDUIT <br />T <br />EXISTING TELEPHONE SYSTEM <br />E <br />EXISTING ELECTRICAL SYSTEM <br />G <br />EXISTING GAS SYSTEM <br />TV <br />EXISTING TV SYSTEM <br />IRR <br />EXISTING IRRIGATION SYSTEM <br />JT <br />EXISTING JOINT TRENCH <br />ss <br />EXISTING SANITARY SEWER <br />so <br />EXISTING STORM DRAIN <br />w <br />EXISTING WATER LINE <br />x x x <br />EXISTING FENCELINE <br />ROAD/WAY CENTER LINE <br />FL <br />PROPERTY LINE <br />P E <br />PG&E LINE <br />CaIAAI <br />COMMUNICATION LINE <br />ABBREVIATIONS <br />COMCAST COMCAST <br />PIE <br />PROPERTY LINE <br />CL CENTER LINE <br />POE <br />PUBLIC UTILITY EASEMENT <br />(E) EXISTING <br />R/W <br />RIGHT OF WAY <br />(N) NEW <br />BOW <br />BACK OF WALK <br />FOC FACE OF CURB <br />SD <br />EXISTING STORM DRAIN <br />MIN MINIMUM <br />SS <br />EXISTING SANITARY SEWER <br />MAX MAXIMUM <br />T <br />EXISTING TELEPHONE <br />D/W DRIVEWAY <br />W <br />EXISTING WATER <br />O/S OFFSET <br />R/R <br />REMOVAL/REPAIR <br />SYMBOLS <br />NEW COMCAST POWER SUPPLY <br />Q TRANSFORMER <br />® <br />NEW COMCAST LOW PROFILE <br />m 9 <br />STREET LIGHT <br />POWER SUPPLY W/METER <br />{� <br />T TRAFFIC SIGNAL COMBINATION <br />0 <br />NEW COMCAST VAULT <br />FIRE HYDRANT <br />m <br />NEW COMCAST PEDESTAL <br />® <br />MONUMENT <br />BORE PIT <br />[Ell CATCH BASIN <br />®' <br />NEW RISER ATTACHED TO POLE <br />® <br />EXISTING POLE <br />® <br />STORM DRAIN MANHOLE <br />O <br />WATER MANHOLE <br />Is] <br />EXISTING COMCASTVAULT <br />® <br />SANITARY SEWER MANHOLE <br />® <br />EXISTING COMCAST PEDESTAL <br />® <br />SEWER CLEAN OUT <br />O <br />EXISTING IRRIGATION VAULT <br />OE <br />ELECTRIC MANHOLE <br />O <br />EXISTING UTILITY VAULT/PEDESTAL <br />® <br />UNIDENTIFIED MANHOLE <br />>*,— <br />GAS/WATER VALVE <br />® <br />WATER METER <br />TREE/BUSHES <br />© <br />GAS METER <br />THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL <br />DESIGN: N.PE <br />I REV DESCRIPTION <br />DATE <br />0 ISSUE FOR PERMIT <br />06/06/2025 <br />DRAWN BY: SB/RZ <br />I <br />DRAWN BY: <br />APPROVED. <br />APPROVED: <br />GENERAL NOTES: <br />1 ALL VAULTS/ HANDHOLES TO BE EQUIPPED WITH SECURITY LIDS WITH LOCKING BOLTS <br />2 GROUND RESTORATION/RIGHT-OF-WAY SHALL BE RESTORED TO ORIGINAL OR BETTER CONDITION <br />3 ALL 90 DEGREE BENDS IN CONDUIT CONSTRUCTION WILL BE A MINIMUM OF 36" RADIUS UNLESS <br />SPECIFIED OTHERWISE <br />4 BURIED FIBER OPTIC WARNING SIGNS SHALL BE PLACED AT EACH SIDE OFALL ROAD CROSSINGS, <br />AT CULVERTS, DITCHES AND IN A STRAIGHT LINE OF SIGHT SPACING OF APPROXIMATELY 500 FEET <br />5 DEVIATIONS FROM THE ENGINEERED ROUTE REQUIRESA PROJECT MANAGERAND RIGHT-OF-WAY <br />OWNER OF CARETAKER APPROVAL PRIOR TO CONSTRUCTION <br />6 WHERE PERMITS FROM STATE,COUNTY,CITY, RAILROAD OR GOVERNMENT AGENCIES ARE <br />REQUIRED, ALL WORK PERFORMED WILL COMPLY WITH THESE AGENCIES STANDARD <br />SPECIFICATIONS <br />7 THE PROJECT MANAGER WILL NOTIFY BUILDING MANAGEMENT WHEN WORK WILL BEGIN ON <br />BUILDING CONTRACTOR TO COORDINATE ROOM ACCESS AND WORK START AND STOP TIMES <br />WITH BUILDING MANAGEMENT <br />8 THE PROJECT MANAGER ISTO BE NOTIFIED BYTHE CONTRACTOR 24 HOURS PRIORTO <br />CONSTRUCTION SEE COMPANY CONTACT LIST FOR CONTACT NAME(s) AND TELEPHONE <br />NUMBER(s) <br />9 THE PROJECT MANAGER WILL RESERVE THE RIGHT TO INSPECT AT ANYTIME THE WORK BEING <br />PERFORMED BYTHE CONTRACTOR IF PROJECT MANAGER DETERMINES THAT THE WORK IS NOT <br />BEING PERFORMED TO MINIMUM QUALITY STANDARDS, THEN THE CONTRACTOR SHALL PROVIDE <br />REWORK AT HIS OWN COST <br />10 ANY CHANGE IN PROJECT SCOPE, INCLUDING BUT NOT LIMITED TO, CONDUIT LENGTH, CONDUIT <br />PATH, AERIAL PATH ETC MUST BE APPROVED BY THE PROJECT MANAGER <br />11 ALL CORING/CONSTRUCTION THAT WILL CAUSE NOISE AND/OR VIBRATION SHALL BE DONE WITHIN <br />ALLOWED (9AM-3PM) BUSINESS HOURS <br />12 ANY AND ALL UNDERGROUND UTILITIES ENCOUNTERED ARE THE RESPONSIBILITY OF THE <br />CONTRACTOR TO LOCATE, PROTECT AND REPAIR, IF DAMAGED <br />13 ALL FOOTAGES ARE BASED ON FIELD GATHERED MEASUREMENTS, AS SUCH SOME VARIANCE <br />SHOULD BE ANTICIPATED ADIUSTAS NEEDED <br />14 ALL BURIED CONDUIT/CABLE WILL BE PLACED AT 36" MINIMUM COVER SITE HAS POTENTIAL FOR <br />ROCK THAT WOULD PREVENT THE ABILITY TO PROVIDE THEM INIM UM COVER, IN CASES WHERE <br />THE MINIMUM COVER CANNOT BE ACHIEVED, THE CONDUIT SHALL BE PLACED IN A SCH 40 EMT SLEEVE <br />OR APPROVED EQUIVALENT <br />15 WATER,SEWER, STORM SEWER AND EASEMENT LOCATIONS ARE BASED OFF OF CITY MAPS, <br />NOT FIELD VERIFIED <br />16 BORING OF AC PAVING IS REQUIRED ATALL LOCATIONS AS INDICATED ON PLANS <br />17 AT NO TIMES SHALL CURBS, GUTTERS OR HANDICAP BE DISTURBED <br />18 DOOR HANGERS ARE TO BE PLACED A MINIMUM OF 102 HOURS PRIOR TO START OF CONSTRUCTION <br />19 PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL PLACE MESSAGE BOARDS STATING <br />LANE CLOSURES, AND DELAYS A WEEK IN ADVANCE, LOCATION OF THE MESSAGE BOARD SHALL BE <br />COORDINATE WITH THE CITY INSPECTOR ATTHE PRE -CONSTRUCTION MEETING <br />20 LANE CLOSURES CANNOT EXCEED MORE THAN 300 FT ATA TIME FOR SAFETY PURPOSES THERE <br />SHALL BE ONLY ONE CLOSURE ATA TIME ALONG S GARDEN AVE & E LAFAYETTE ST MORE FLAGGERS <br />WILL BE NECESSARY TO HELP VEHICLES AND PEDESTRIANS IN THE WORK LUNES DURING THE LANE CLOSURES <br />IMPORTANT NOTICE <br />Section M 4216/4217 of the Government Code requires a <br />Dig Alert Identification Number to be issued before a <br />"Permit to Excavate" will be valid For your Dig Alert I.D. <br />CALL TOLL FREE <br />48 HOURS BEFORE YOU DIG <br />UNDERGROUND SERVICE ALERT <br />1-800-227-2600 <br />FIBER PLACEMENT NOTES: <br />1 CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES 48 <br />HOURS PRIOR TO CONSTRUCTION ACTIVITY <br />SEE LOCAL DIRECTORY FOR CONTACT TELEPHONE NUMBER OF <br />LOCAL CALL BEFORE YOU DIG AGENCY <br />2 CONTRACTOR SHALL RECORD SEQUENCE# OF FIBER CABLE AT <br />EVERY WORK POLE, MANHOLE, FIBRE STORAGE LOOP <br />AND TAIL LOCATION CONTRACTOR TO PROVIDE PROJECT <br />MANAGER WITH SEQUENCE NUMBERS AT PROJECT <br />COMPLETION <br />3 SLACK LOOP AND SNOWSHOE STORAGE LOCATIONS SHALL BE <br />DETERMINED ON CONSTRUCTION DRAWINGS, HOWEVER, <br />REEL LENGTHS OF FIVE HUNDRED FEET (500') OR LESS ON LARGE <br />COUNT FIBER OR THREE HUNDRED (300') OR LESS <br />ON SMALL COUNT FIBER ARE DIFFICULT TO USE AND SHOULD BE <br />PLACED AS FSL'S, NOT CUT AND RETURNED <br />4 FIBER OPTIC IDENTIFICATION TAGS SHALL BE PLACED AT EVERY <br />WORK POLE, MANHOLE, FIBER, STORAGE LOOPS, SPLICE <br />CASES AND WHERE INDICATED BY PROJECT MANAGER TAGS <br />NEED TO BE PLACED SO AS TO BE READ FROM THE GROUND <br />5 CABLE LUBRICATION SHALL BE USED TO REDUCE PULLING <br />TENSION LUBRICANTS MUST NOT CONTAIN ANY PETROLEUM <br />PRODUCTS <br />6 A 100 FOOT FIBER COIL MUST REMAIN IN ALL VAULTS UNLESS <br />OTHERWISE NOTED <br />7 ALL BURIED INFRASTRUCTURE MUST BE ACCOMPANIED WITH <br />WARNING TAPE AND A TRACER WIRE, AT RISER POLES THE <br />LOCATE WIRE SHALL BE ACCESSIBLE ATTHE BASE OFTHE RISER <br />8 ALL RISERS WILL BE CAPPED ATALLTIMES <br />9 ALL FIBER SHALL BE MARKED ASTO DIRECTION IN EACH VAULT <br />RED -NORTH, GREEN -SOUTH, YELLOW -EAST, AND <br />BLUE -WEST. DO NOTTAPE FIBER CABLES TOGETHER IN RISER <br />DISCLAIMER: <br />1 IT IS THE RESPONSIBILITY OF THE CONSTRUCTION CONSTRUCTOR <br />TO VERIFY ALL RIGHT OF WAY BEFORE CONSTRUCTION IS TO <br />BEGIN NO UNDERGROUND INSTALLATION REPRESENTED WITHIN <br />THESE PLAN SHEETS IS PROPOSED OUTSIDE OF THE RIGHT OF <br />WAY <br />2 THE UNDERGROUND ROUTE DEPICTED IS PRELIMINARY AND <br />WILL/MAY VARY ONCE UTILITIES HAVE <br />BEEN FIELD LOCATED <br />3 ANCHORING FOR THE AERIAL CONSTRUCTION IS TYPICALLY <br />DETERMINED DURING CONSTRUCTION AND IS COLLECTED IN THE <br />AS -BUILT PHASE <br />PROJ#: J62159791 <br />CONSTRUCTION TYPE: SPLICING <br />SYSTEM: STOCKTON <br />NODE. <br />ass cla�oo na <br />tonw� ,CA, 91511 <br />Plann =NG ¢plennenp@pmalkom <br />fi wI.. "@s .Eem <br />SHEET: 2 OF 28 <br />
The URL can be used to link to this page
Your browser does not support the video tag.