Laserfiche WebLink
SHEET OVERVIEW <br />SHEET 01- TITLE/ CONSTRUCTION NOTES <br />SHEET 02 - EXCAVATION LOCATION A <br />SHEET 03 - EXCAVATION LOCATION B <br />SHEET 04- EXCAVATION LOCATION C <br />SHEET 05 - EXCAVATION LOCATION D <br />SHEET D6-LEGEND <br />CONTACT INFORMATION <br />MICHEIS, PROJECT MANAGER <br />Rebecca Turley (916)-805-6786 <br />MICHEIS, PROJECT MANAGER <br />Raul Gutierrez (408)-391-0508 <br />PG&E PROJECT MANAGER <br />Jesse Higgmson (925)-557-5366 <br />PG&E CONSTRUCTION MANAGER <br />Steve Roberts (916)-622-4955 <br />PG&E DA ENGINEER <br />Michael Blob urn <br />PG&E PIPELINE ENGINEER <br />GENERAL NOTES: <br />1 THIS DRAWING IS ISSUED FOR PERMIT REFER TO CONTRACT DOCUMENTATION FOR ADDITIONAL CLARITY <br />OF SCOPE OF WORK <br />2 THIS DRAWING HAS BEEN CREATED BY REVIEW OF THE AS -BUILT DRAWINGS& RECORDS ACCURACY IS <br />DEPENDENT UPON THE SOURCE DOCUMENTS LISTED IN THE REFERENCE DOCUMENTS <br />3 UTILITIES SHOWN ON DRAWING ARE APPROXIMATE BASED UPON REVIEW OF PG&E DIG SHEET, DIGS <br />BASIS MEMO, &CIS CONTRACTOR TO CALL USA TO HAVE LOCATION O F THESE FACILITIES MARKED& <br />POTHOLE TO EXPOSE/VERIFY LOCATION <br />CONSTRUCTION NOTES' <br />UNDERGROUND SERVICE ALERT CALL 811(1-900-227-2600) A MINIMUM OF 2 BUSINESS DAYS (NOT <br />INCLUDING INITIAL DAY OF CONTACT) IN ADVANCE FOR THE MARKING OF UNDERGROUND UTILITIES, <br />INCLUDING ALL NON -UTILITIES BEFORE YOU DIG, GRADE, OR EXCAVATE <br />UTILITY NOTES <br />A DIMENSIONS SHOWN ON THESE DRAWINGS ARE BASED ON THE BEST AVAILABLE INFORMATION <br />FROM SEVERAL SOURCES, & SHALL BE VERIFIED IN THE FIELD BY CONSTRUCTION PERSONNEL PRIOR <br />TO EXCAVATION <br />B THE INFORMATION SHOWN ON THESE DRAWINGS CONCERNING TYPE & LOCATION OF <br />UNDERGROUND UTILITIES, PROPERTY LINES, & OTHER SUBSTRUCTURES IS NOT GUARANTEED TO BE <br />ACCURATE OR ALL-INCLUSIVE, UNLESS OTHERWISE NOTED CONSTRUCTION PERSONNEL ARE <br />RESPONSIBLE FOR MAKING ALL DETERMINATIONS AS TO THE TYPE & LOCATION OF UNDERGROUND <br />UTILITIES & OTHER SUBSTRUCTURES AS NECESSARY TO AVOID DAMAGE OR ENCROACHMENTS <br />C PROSPECTING IS REQUIRED AHEAD OF WORK <br />D ALL EXCAVATIONS WITHIN EXISTING STATIONS SHALL BE HAND DUG OR EXCAVATED USING SOFT <br />DIG METHODS (e g VACUUM EXCAVATIONS OR SIMILAR) <br />PACIFIC GAS & ELECTRIC <br />EC25-108, D-1757 <br />STUB14522, 1613-06, 1614-02 <br />ECDA INVESTIGATION DIG <br />ORDER #84023969 <br />3 COATING REMOVAL <br />BEFORE REMOVING THE PIPE COATING ON PRE-1972 PIPE (DOES NOT INCLUDE PLASTIC TAPE OR FUSION <br />BONDED EPDXY COATINGS) THE FOLLOWING STEPS SHALL BETAKEN <br />A FOR ALL NON -EMERGENCY WORK, PRE-1972 PIPE WRAP MUST BE EVALUATED TO DETERMINE IF IT <br />CONTAINS ASBESTOS PRIOR TO REMOVAL <br />B FOR EMERGENCY WORK ON PRE-1972 PIPE, ASSUME THE WRAP CONTAINS> 1%ASBESTOS UNTIL <br />THE W RAP CAN BE TESTED <br />C OBTAIN SAMPLES OF THE WRAP, & HAVE SAMPLES TESTED FOR ASBESTOS IN ACCORDANCE WITH <br />WP 4711-01 <br />D TEST RESULTS ARE TO BE INCLUDED WITH THE FINAL JOB PACKAGE <br />E FOLLOW PROCEDURE IN WP 4711-01 FOR REMOVAL OF PIPE WRAP <br />4 RESTORATION & CLEAN UP <br />A RESTORATION OF PUBLIC STREETS, SIDEWALKS, CURBS, ETC ABOVE PIPE BEDDING SHALL BE IN <br />ACCORDANCE WITH THE LATEST CITY, COUNTY, OR AGENCY STANDARDS <br />B WHEREVER THERE ARE ROW CROPS, THE TOPSOIL SHALL BE REMOVED TO A DEPTH OF 12" & <br />STORED ON SITE UPON COMPLETION OF CONSTRUCTION, THE TOPSOIL SHALL BE RESTORED TAKE <br />CARE TO PREVENT MIXING OF TOPSOIL & SUBSOIL <br />5 WELDING REQUIREMENTS <br />A INSTALL TEST STATONS WITH THERMITE WELD CONNECTION IN ACCORDANCE WITH GAS T & D <br />CORROSION CONTROL MANUAL 0-10, 0-10 1, & 0-10 2 <br />6 PAINTING & COATING REQUIREMENTS <br />A ALL EXPOSED PIPE & FITTINGS ARE TO BE PAINTED IN ACCORDANCE WITH GAS STANDARD E-30 ALL <br />COATING ON BURIED PIPE & FITTINGS ARE TO BE APPLIED IN ACCORDANCE WITH GAS STANDARD <br />E-3S <br />B FOR COATING SELECTIONS ON BURIED PIPE, SEE DIRECT BURIAL COATING SELECTIONS TABLE <br />7 DOCUMENTATION OF INSPECTION OF EXISTING PIPELINE <br />WHENEVER EXISTING BURIED GAS FACILITIES ARE EXCAVATED DURING ENGINEERING OR DURING <br />CONSTRUCTION, AN A -FORM (TD-411OP-03401) SHALL BE COMPLETED FOR THE GENERAL INSPECTION <br />THIS ALSO APPLIES TO GAS FACILITIES BEING DEACTIVATED THE COMPLETED A -FORM SHALL BE <br />SUBMITTED WITH THE FINAL JOB PACKAGE <br />8 COPIES OF REFERENCE DRAWINGS ARE AVAILABLE TO FIELD PERSONNEL (PG&E, INSPECTION OR <br />CONTRACTOR) ON AN AS NEEDED BASIS CONTACTTHE CONTRACT ENGINEER IDENTIFIED IN CONTACTS <br />TO OBTAIN COPIES OF REFERENCE DRAWINGS <br />VICINITY MAP LODI, CA <br />NOT TO SCALE <br />1EQUE NST/CLLBekjRATIONS• <br />2 EXCAVATE & EXPOSE PIPELINE AS SHOWN IN LOCATION IMAGE(S) & IDENTIFIED IN <br />ECDA DIG SHEET (FORM N) <br />3 COMPLETE PIPELINE INSPECTION IN ACCORDANCE WITH RMP-09 PROCEDURE FOR <br />EXTERNAL CORROSION DIRECT ASSESSMENT <br />4 COMPLETE "H" FORM INSPECTION <br />5 PERFORM REPAIRS AS NEEDED <br />6 RECOATTHE PIPELINE IN ACCORDANCE WITH GAS STANDARD E-35 <br />7 COMPLETE DOCUMENTATION AS REQUESTED BYTHE PROJECT ENGINEER <br />8 BACKFILL & COMPACT EXCAVATION PER PERMIT STANDARDS <br />9 INSTALL PG&E GAS WARNING DECALS & PIPELINE MARKER DECALS AS NEEDED <br />30 REMOVE BMPS <br />11 RESTORE PROJECT SITE <br />APPROVED I GM <br />SUPV <br />WARNING <br />SCALE IS APPROXiraATE <br />LOCATION OF EXISTING <br />DSGN <br />THIS DOCUMENT CONTAINS CONFIDENTIAL, PROPRIETARY <br />INFORMATION THAT IS THE SOLE PROPERTY OF PACIFIC <br />19 <br />ED S <br />AND PROPOSTRUCTURES IS <br />DWN TR1 <br />GASAND ELECTRIC COMPANY AND IS INTENDED FOR USE <br />APPROXIMATE ANYAND <br />CHKD <br />ONLY BY AUTHORIZED PACIFIC GAS AND ELECTRIC <br />COMPANY EMPLOYEES& AGENTS COPYRIGHT PACIFIC <br />Know what': below. <br />A 5/27/2025 ISSUED FOR PERMIT <br />DRAWING SIZE 1­17" <br />84023969 TRl OK <br />GAS AND ELECrRIC COMPANY <br />Cell before you dig, <br />NO. DATE DESCRIPTION <br />GM/SPEC DWN CHKD SUPV APVDBY DATE 5/27/2025 <br />ACRDSDLrRiNa <br />SCALES <br />REVISIONS <br />AS SHOWN <br />.FETY <br />SAFETY PLEDGE <br />uvux wr susir nRsr. <br />' I iL01f —AND ALr 10 <br />_ENs —Y <br />MICHELS" <br />817 Main Street <br />Brownsville, WI <br />(920)583-3132 <br />www michels us <br />ISSUED <br />FOR <br />PERMIT <br />EC25-108, D-1757 <br />STUB14522, 1613-06, 1614-02 <br />ECDA INVESTIGATION DIG <br />LODI, CALIFORNIA <br />84023969 JOB It 25056831 'S OFT B I REV <br />