My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
EP-00-265
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2000
>
EP-00-301 thru EP-00-400
>
EP-00-265
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2025 10:33:22 AM
Creation date
10/24/2025 10:14:05 AM
Metadata
Fields
Template:
Permits_Development
DocName
EP-00-265
Category07
Encroachment(EP)/Driveway(DW) Permits
Year2
2000
Location
Various Roads
Type - Permit Process
Bell Holes & Fiberoptic Cable for Long Distance Communication
Address
110 W. 7th St., Suite 500, Tulsa,OK 74119
Application
Williams Communications, Inc. dba VYVX Inc.
Project #
11005
Type
Encroachment Permit
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ENCROACHMENT PERMIT <br /> <br />E.P. No. 00-265-ALL <br />Date Issued: 6-13-00 <br />Expiration Date: 7-1-01 <br />Job No.: 11005 <br /> <br />To: Williams Communications, Inc. <br />dba VYVX Inc. <br />110 W. 7th St., Suite 500 <br />Tulsa, OK 74119 <br /> <br />Encroachment Type: Bell Hole & Fiberoptic Cable <br />for Long Distance Communication <br /> <br />In compliance with your request of 6-8, 2000, permission is hereby <br />granted to do work in County right of way as shown on attached application and subject to <br />all the terms, conditions and restrictions written below or printed as general or special <br />provisions on any part of this form. See reverse side and attached sheet, if any. <br /> <br />Trench excavations for service connections will not be permitted within ten feet (10') <br />of pavement centerline unless otherwise approved by the Director. Surface of trench patches <br />shall match in kind and be smooth and even with that of abutting surface. Special attention <br />shall be given to depth of utilities through roadside area in anticipation of future drain- <br />age facilities, road profile and/or frontage development. All underground utility facili- <br />ties are to be established and accurately dimensioned on sketches from surveyed centerline <br />of road right of way, not from right of way (border) lines. <br /> <br />The Department of Public Works, Field Inspection Section shall receive a notice at <br />least forty-eight (48) hours prior to beginning any work within the County right of way. <br />All work performed under this permit shall conform to the rules and regulations pertain- <br />ing to safety established by the California Division of Industrial Safety and Cal -OSHA. <br /> <br />The jobsite shall be kept in a safe condition at all times by the daily removal of <br />any excess dirt or. debris which might be a hazard to either pedestrian or automobile <br />traffic. All necessary traffic convenience and warning devices and personnel shall be <br />provided, placed and maintained by and at the sole expense of the Permittee in accordance <br />with the latest edition of the CALTRANS Manual of Traffic Control. <br /> <br />After completion of the work permitted herein, all debris, lumber, barricades, or any <br />excess material shall be removed and the jobsite left in a neat workmanlike manner. <br />Immediately following completion of construction permitted herein, Permittee shall <br />out and mail notice of completion provided by Grantor. <br /> <br />NOTE: Permits shall be requored from the following prior to working in their easements or right of way: Caltrans, W.P.R.R., <br />S.P.R.R., City of Tracy, Escalon & Stockton, and Banta-Carbona Irrigation District. A $5,000 bond will be returned to Williams <br />Communications, Inc. upon receipt of As Builts and approval from the Field Inspection Division. If Handhole Box is within 6' of the <br />edge of pavement, the box and lid need to be traffic rated. A 7 day notice is required for any Traffic Control (Exhibit "E"). <br /> <br />Est. Permit Fee: $28,810.24 <br />FORMS: SS/WW, R-29 <br /> <br />HENRY M. HIRATA, Director <br />Department of Public Works <br />By John Wotila <br />Permit Section <br /> <br />WHITE - Permittee <br />GOLDENROD - PWD Central File <br />YELLOW - Field Inspection <br />PINK - Permit Section
The URL can be used to link to this page
Your browser does not support the video tag.