My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2014_PS-1401501 thru PS-1402000_ - PS-1401742
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2014
>
PS-1401501 thru PS-1402000
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2014_PS-1401501 thru PS-1402000_ - PS-1401742
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 4:25:58 PM
Creation date
12/31/2015 12:20:37 PM
Metadata
Fields
Template:
Permits_Development
DocName
PS-1401742
Category07
Encroachment(EP)/Driveway(DW) Permits
SubCategory07
2014\PS-1401501 thru PS-1402000
Year2
2014
Supplemental fields
Applicant
PACIFIC GAS & ELECTRIC- STOCKTON
Contracts
CrossReference
Description
ENCROACHMENT PERMIT
DocCategory
Permit Applications (PA)
Notes
Owners
Parcel Address
W/S OF EXTENSION RD. 282' S/O HARNEY LN.
Primary Parcel
Type (2)
PS-1401742
Tags
Permits_Development
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Backfill with materials equal to or <br /> better than the existing pavement <br /> and base in quality. New pavement <br /> shall be 1" thicker than existing <br /> pavement, minimum of 0.25 feet. <br /> New base shall be 1" thicker than <br /> existing base, minimum of 0.5 feet. <br /> Existing <br /> Pavement <br /> T <br /> Compact in 12" max. 31-0" <br /> 3 -0. \ layers to a min. relative \ <br /> \ compaction of 95,%# <br /> under pavement and _—__----_ <br /> __________ / 90% outside pavement. _ _--_---- Variable <br /> Variable ___-- Compact in 24 max. <br /> — -- layers to a min. relative O OD+12" <br /> compaction of 85%. O <br /> O.D./2 Compact in 6" layers <br /> to a minimum relative <br /> compaction of 90%. <br /> 10" Min. O.D. 10" Min. 10" Min. O.D.—* 10" Min. <br /> O.D. O.D. <br /> + 20" Min. + 20" Min. <br /> RIGID CONDUIT FLEXIBLE CONDUIT <br /> NOTES: <br /> 1. Relative compaction of materials shall be tested. in accordance with <br /> the State of California., Dept. of Transportation Testing Manuals, test <br /> method No. California 216 or 231. <br /> 2. All existing pavement shall be neatly cut to line prior to trench excavation. <br /> 3. Jetting or ponding will be permitted within the street Right of Way with <br /> a 3 year bond. <br /> 4. When shown by soil composition and compactability, ninety percent (90%) <br /> compaction may be used, when approved by the Director of Public Works. <br /> 5. Special bedding requirements may be shown on the plans or specified in <br /> special provisions. <br /> 6. Shoulders shall be as shown on the plans or specified in the special <br /> provisions but in no case shall the shoulder be less than three feet wide <br /> as measured from the edge of pavement. <br /> N . Revised By Approved by <br /> ' Feb' 1996 PD TYPICAL TRENCH BACKFILL >?2- <br /> Directof of Public Works <br /> Drawn by JLD <br /> cnoge COUNTY OF SAN JOAQUIN Date JUNE 1997 <br /> Scale NONE DerAmteexr OF PUBLIC WOPHS - Drawing No. R-29 <br />