My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2014_PS-1402501 thru PS-1403000_ - PS-1402988
PublicWorks
>
- PUBLIC SERVICES
>
PERMITS & DEVELOPMENT
>
Encroachment(EP)/Driveway(DW) Permits
>
2014
>
PS-1402501 thru PS-1403000
>
Permits & Development - Encroachment(EP)/Driveway(DW) Permits - 2014_PS-1402501 thru PS-1403000_ - PS-1402988
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 4:29:54 PM
Creation date
12/31/2015 1:39:25 PM
Metadata
Fields
Template:
Permits_Development
DocName
PS-1402988
Category07
Encroachment(EP)/Driveway(DW) Permits
SubCategory07
2014\PS-1402501 thru PS-1403000
Year2
2014
Supplemental fields
Applicant
ROBERT BURNS CONTRUCTION, INC
Contracts
CrossReference
Description
ENCROACHMENT PERMIT
DocCategory
Permit Applications (PA)
Notes
SEE DRWINGS
Owners
Parcel Address
BOTH SIDES OF WOODBRO RD. 1 MILE N/OF HWY. 4
Primary Parcel
Type (2)
PS-4102988
Tags
Permits_Development
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DEPARTMENT OF PUBLIC WORKS <br /> 2. Longitudinal Trenches within Traveled Lanes- <br /> The entire traveled lane where the trench is located is to be resurfaced <br /> with a one(1) inch asphalt concrete.overlay. The existing surfacing <br /> adjacent to the trenched area shall be planed to accornmodate the overlay <br /> in a manner that does not cause drainage concerns. The overlay shall be <br /> in accordance with State Standard S.pecifiications, Section 39. Aggregate <br /> gradation shall be consistent with the existing surfacing material. (see <br /> EXHIBIT 1: LONGITUDINAL CUTTING OF COUN IY ROADWAYS.) <br /> 3, Gross-Cuttting: <br /> Cross-c-rting is allowed at a minimum interval of one hundred fifty (130) <br /> feet. At each cross-cuff location-a minimum of ten (10)feet each side of <br /> trench shall be planed and resurfaced with one (1) inch asphalt-concrete. ' <br /> If cross cuts are within the 150 fee minimum interval,the entire section <br /> _. between-tne-irr-sf and-Iasi cr-osscuz shall-be-planed-arid-resurfaced w�ih <br /> one(1) inch asphalt concrete. (See EXHIBIT 2: CROSS GUTTING OF <br /> COUNTY ROADWAYS.) <br /> 4. The conditions described in paragraphs 1, 2 and 3 above will not apply if <br /> resurfacing is scheduled within two years_ <br /> 3910.3 LOCAL ROADS <br /> A. Surfacing Age Under Three (3)Years.- No pavement cuts'allowed. Exceptions <br /> may be-approved-in accordance with Section 3910.4 EXCEPTIONS. <br /> B. Surfacing Age Three(3)to Five(5) Years: <br /> 1. Longitudinal-cuts are permitted. A seal coat is required for that half of-the <br /> roadway containing the trench. (See EXHIBIT 1: LONGI T UD-INAL <br /> CUTTING OF COUNTY ROADWAYS.) <br /> 2. . Gross-catling is allowed under the same conditions as Section 3910.2B-3. <br /> If cross cuts occur within the 150 feet minimum-interval,-resurfacing may <br /> be substituted with a slurry seal for that half of the roadway. (See <br /> EXHIBIT 2: CROSS CUTTING OF COUNTY ROADWAYS.) <br /> 3910.4 EXCEPTIONS <br /> Excavation is-prohibited in newly renovated County roadways forthree(3)years after a <br /> nonce of completion has been-riled for a roadway improvement project, or a new <br /> roadway has been accepted. The Director of Public Works-may approve exceptions <br /> that are in the best interest of the public, including but rrot limited to: <br /> A_ An emergency that endangers life or property. <br /> B. For repair or modificaflon to prevent interruption of essential utility-service. <br /> C_ For relocation work that is mandated by County, State or Federal law. <br /> D. For service for buildings where no other reasonable means of providing service <br /> exists. <br /> E. For potholing to verify utility depth or location. <br /> SISUSANPP,DCEDUP.ES091DDRAFT NOGE$9-12-12DDC PAGE20F3 REVISED 09-12-12 . <br /> REVISION NO. 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.