Location
2459 Wandman Ave.
Type - Permit Process
This project proposes to overpull approx. 27' from county limit to exist. pole #1. Locate and intercept exist. duct to set wye cast via placing bore pit #1. Hand trench approx 5' to place 2-2" conduit & cable from bore pit #1 to county right-of-way line on Waudman Ave.
Application
Congruex
Project #
110005
Type
Utility Encroachment
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
LINETYPES <br />PROPOSED BORE ROUTE <br />- <br />NEWAERIALSTRAND <br />PROPOSED TRENCH/ R/SW ROUTE <br />Ctl9 CMY <br />NEW AERIAL ROUTE <br />CAW Cl" <br />EXISTING COMCAST ROUTE <br />a t' r <br />EXISTING TELEPHONE SYSTEM <br />x z ■ <br />EXISTING ELECTRICAL SYSTEM <br />c a c <br />EXISTING GAS SYSTEM <br />CAW CA" <br />EXISTING TV SYSTEM <br />04R Dm 1RR <br />EXISTING IRRIGATION SYSTEM <br />n n n <br />EXISTING JOINT TRENCH <br />sa as aB <br />EXISTING SANITARY SEWER <br />aD sD aD <br />EXISTING STORM DRAIN <br />x x <br />EXISTING WATER LINE <br />x z x <br />EXISTING FENCELINE <br />C/L C/t <br />ROADWAY CENTER LINE <br />- <br />PROPERTY LINE <br />ROW LINE <br />PUE/PSE/EASEMENT LINE <br />EOP/FOC/S I DE WALK/CU RB <br />- <br />R&R LINE <br />ABBREVIATIONS <br />ADA <br />AMERICANS WITH DISABILITY ACT <br />PA <br />PROPERTY LINE <br />CA <br />CALIFORNIA <br />FILE <br />PUBLIC UTILITY EASEMENT <br />CA <br />CENTERLINE <br />ROW <br />RIGHT OF WAY <br />EXIST. <br />EXISTING <br />SS <br />EXISTING STORM DRAIN <br />MIN <br />MINIMUM <br />T <br />EXISTI NG TELEPHONE <br />MAX <br />MAXIMUM <br />W <br />EXISTING WATER <br />CNDT <br />CONDUIT <br />E <br />EXISTING ELECTRIC <br />BOW <br />BACK OF WALK <br />IRR <br />EXISTING IRRIGATION <br />FOW <br />FRONT OF WALK <br />G <br />EXISTI NG GAS <br />EOP <br />EDGE OF PAVEMENT <br />D/W <br />DRIVEWAY <br />COMCAST <br />COMCAST <br />R&R <br />REMOVE & REPLACE <br />PL <br />PLACE <br />N <br />NEW <br />Sq. Ft. <br />ISQUARE FEET <br />IPSE <br />IPUBLIC SERVICE EASEMENT <br />APPROX <br />JAPPROXIMATE <br />IDIA <br />IDIAMETER <br />SYMBOLS <br />® <br />NEWCOMCASTPOWERSUPPLY <br />Q <br />TRANSFORMER '+- NEWANCHOR <br />NEW COMCAST LOW PROFILE <br />STREETLIGHT TELCO MANHOLE <br />POWER SUPPLY W/METER <br />T` <br />TRAFFIC SIGNAL COMBINATION <br />NEW COMCAST VAULT <br />m <br />NEW COMCAST PEDESTAL <br />b <br />FIRE HYDRANT <br />® <br />BORE/DIG PIT <br />pi <br />MONUMENT <br />® <br />CATCH BASIN <br />NEW RISER ATTACHED TO POLE <br />SD <br />STORM DRAIN MANHOLE <br />® <br />EXISTING POLE <br />® <br />NEW POLE <br />WATER MANHOLE <br />FQ <br />EXISTING COMCAST VAULT <br />SANITARY/ STORM SEWER MANHOLE <br />® <br />EXISTING COMCAST PEDESTAL <br />® <br />SEWER CLEAN OUT <br />O <br />EXISTING IRRIGATION VAULT <br />ELECTRIC MANHOLE <br />EXISTING UTILITY VAULT/PEDESTAL <br />q71® <br />GAS/WATER/SS/ELECTRIC VALVE <br />® <br />UNIDENTIFIED MANHOLE <br />❑W <br />WATER METER <br />TREE/BUSHES <br />© <br />GAS METER <br />PH <br />POTHOLE <br />b <br />STREETSIGN <br />GENERAL NOTES: <br />1. ALL VAULTS/ HANDHOLES TO BE EQUIPPED WITH SECURITY LIDS WITH LOCKING BOLTS <br />FIRFR PI A('FMFNT IV()TFq <br />1. CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL UTILITIES 48 HOURS <br />2. GROUND RESTORATION/RIGHT-OF-WAY SHALL BE RESTORED TO ORIGINAL OR BETTER CONDITION <br />PRIOR TO CONSTRUCTION ACTIVITY SEE LOCAL DIRECTORY FOR CONTACT <br />TELEPHONE NUMBER OF LOCAL CALL BEFORE YOU DIG AGENCY. <br />3. ALL 90 DEGREE BENDS IN CONDUIT CONSTRUCTION WILL BE A MINIMUM OF 36" RADIUS UNLESS <br />SPECIFIED OTHERWISE. <br />2. CONTRACTOR SHALL RECORD SEQUENCE it OF FIBER CABLE AT EVERY <br />WORK POLE, MANHOLE, FIBRE STORAGE LOOP AND TAIL LOCATION. <br />4. BURIED FIBER OPTIC WARNING SIGNS SHALL BE PLACED AT EACH SIDE OF ALL ROAD CROSSINGS <br />CONTRACTOR TO PROVIDE PROJECT MANAGER WITH SEQUENCE <br />AT CULVERTS, DITCHES AND IN A STRAIGHT LINE OF SIGHT SPACING OF APPROXIMATELY 500 FEET <br />NUMBERS AT PROJECT COMPLETION. <br />5. DEVIATIONS FROM THE ENGINEERED ROUTE REQUIRES A PROJECT MANAGER AND RIGHT-OF-WAY <br />3. SLACK LOOP AND SNOWSHOE STORAGE LOCATIONS SHALL BE <br />OWNER OR CARETAKER APPROVAL PRIOR TO CONSTRUCTION. <br />DETERMINED ON CONSTRUCTION DRAWINGS, HOWEVER, REEL LENGTHS <br />OF FIVE HUNDRED FEET (500') OR LESS ON LARGE COUNT FIBER OR THREE <br />6. WHERE PERMITS FROM STATE, COUNTY, CITY, RAILROAD OR GOVERNMENT AGENCIES ARE <br />HUNDRED (300') OR LESS ON SMALL COUNT FIBER ARE DIFFICULTTO USE <br />REQUIRED, ALLWORK PERFORMED WILL COMPLY WITH THESE AGENCIES STANDARD <br />AND SHOULD BE PLACED AS FSL'S, NOT CUTAND RETURNED. <br />SPECIFICATIONS. <br />4. FIBER OPTIC IDENTIFICATION TAGS SHALL BE PLACED AT EVERY WORK <br />7. THE PROJECT MANAGER WILL NOTIFY BUILDING MANAGEMENT WHEN WORK WILL BEGIN ON <br />POLE, MANHOLE, FIBER, STORAGE LOOPS, SPLICE CASES AND WHERE <br />BUILDING. CONTRACTOR TO COORDINATE ROOM ACCESS AND WORK START AND STOP TIMES <br />INDICATED BY PROJECT MANAGER. TAGS NEED TO BE PLACED SO ASTO BE <br />WITH BUILDING MANAGEMENT. <br />READ FROM THE GROUND. <br />S. THE PROJECT MANAGER IS TO BE NOTIFIED BY THE CONTRACTOR 24 HOURS PRIOR TO <br />5. CABLE LUBRICATION SHALL BE USED TO REDUCE PULLING TENSION. <br />CONSTRUCTION. SEE COMPANY CONTACT LIST FOR CONTACT NAME(S) AND TELEPHONE <br />LUBRICANTS MUST NOT CONTAIN ANY PETROLEUM PRODUCTS. <br />N UMBER(S). <br />6. A 100 FOOT FIBER COIL MUST REMAIN IN ALL VAULTS UNLESS <br />9. THE PROJECT MANAGER WILL RESERVE THE RIGHT TO INSPECT AT ANY TIME THE WORK BEING <br />OTHERWISE NOTED. <br />PERFORMED BY THE CONTRACTOR. IF PROJECT MANAGER DETERMINES THAT THE WORK IS NOT <br />BEING PERFORMED TO MINIMUM QUALITY STANDARDS, THEN THE CONTRACTOR SHALL PROVIDE <br />7. ALL BURIED INFRASTRUCTURE MUST BE ACCOMPANIED WITH <br />REWORKAT HIS OWN COST. <br />WARNING TAPE AND A TRACER WIRE, AT RISER POLESTHE LOCATE WIRE <br />SHALL BE ACCESSIBLE AT THE BASE OF THE RISER. <br />10. ANY CHANGE IN PROJECT SCOPE, INCLUDING BUT NOT LIMITED TO, CONDUIT LENGTH, CONDUIT <br />PATH, AERIAL PATH ETC., MUST BE APPROVED BYTHE PROJECT MANAGER. <br />8. ALL RISERS WILL BE CAPPED AT ALLTIMES. <br />11. ALL CORING/CONSTRUCTION THAT WILL CAUSE NOISE AND/OR VIBRATION SHALL BE DONE WITHIN <br />9. ALL FIBER SHALL BE MARKED ASTO DIRECTION IN EACH VAULT. <br />ALLOWED (9AM-3PM) BUSINESS HOURS. <br />RED -NORTH, GREEN -SOUTH, YELLOW -EAST, AND BLUE -WEST, DO NOT <br />TAPE FIBER CABLES TOGETHER IN RISER. <br />12. ANYAND ALL UNDERGROUND UTILITIES ENCOUNTERED ARE THE RESPONSIBILITY OF THE <br />CONTRACTOR TO LOCATE, PROTECT, AND REPAIR, IF DAMAGED. <br />DISCLAIMER <br />13. ALL FOOTAGES ARE BASED ON FIELD GATHERED MEASUREMENTS, AS SUCH SOME VARIANCE <br />SHOULD BE ANTICIPATED. ADJUSTAS NEEDED. <br />1. IT ISTHE RESPONSIBILITY OF THE CONSTRUCTION CONTRACTORTO <br />VERIFY ALL RIGHT OF WAY BEFORE CONSTRUCTION ISTO BEGIN. NO <br />14. ALL BURIED CONDUIT/CABLE WILL BE PLACED AT 36" MINIMUM COVER. SITE HAS POTENTIAL FOR <br />UNDERGROUND INSTALLATION REPRESENTED WITHIN THESE PLAN <br />ROCK THAT WOULD PREVENT THE ABILITY TO PROVIDE THE MINIMUM COVER. INCASESWHERE <br />SHEETS IS PROPOSED OUTSIDE OF THE RIGHT OF WAY. <br />THE MINIMUM COVER CANNOT BE ACHIEVED, THE CONDUIT SHALL BE PLACED IN A 5CH 40 EMT SLEEVE <br />OR APPROVED EQUIVALENT. <br />2. THE UNDERGROUND ROUTE DEPICTED IS PRELIMINARY AND WILL/MAY <br />VARY ONCE UTILITIES HAVE BEEN FIELD LOCATED. <br />15. WATER, SEWER, STORM SEWER AND EASEMENT LOCATIONS ARE BASED OFF OF CITY MAPS, <br />NOT FIELD VERIFIED. <br />3. ANCHORING FOR THE AERIAL CONSTRUCTION IS TYPICALLY <br />DETERMINED DURING CONSTRUCTION AND IS COLLECTED IN THE <br />16. BORING OF AC PAVING IS REQUIRED AT ALL LOCATIONS AS INDICATED ON PLANS. <br />AS -BUILT PHASE. <br />17. AT NO TIME SHALL CURBS, GUTTERS OR HANDICAP BE DISTURBED. <br />18. DOOR HANGERS ARE TO BE PLACED A MINIMUM OF 72 HOURS PRIOR TO START OF CONSTRUCTION <br />19. PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL PLACE MESSAGE BOARDS STATING LANE <br />CLOSURES, AND DELAYS A WEEK IN ADVANCE. LOCATION OF THE MESSAGE BOARD SHALL BE <br />COORDINATED WITH THE CITY INSPECTOR AT THE PRE -CONSTRUCTION MEETING. <br />20. LANE CLOSURES CANNOT EXCEED MORE THAN 300 FT. AT A TIME. FOR SAFETY PURPOSES THERE <br />SHALL BE ONLY ONE CLOSURE. MORE FLAGGERS WILL BE NECESSARY TO HELP VEHICLES AND <br />PEDESTRIANS IN THE WORK ZONE5 DURING THE LANE CLOSURES. <br />THIS IS AN COMCAST DOCUMENT, PROPRIETARY & CONFIDENTIAL <br />IMPORTANT NOTICE <br />PLANS PREPARED BY: <br />DESIGN: <br />REV <br />DESCRIPTION <br />DATE <br />Seatbn / 4218/421] of Me Covemment Code requiroe a <br />DIG AIeH Idanliflcation Number to ba Issued before a <br />Z C H C <br />DRAWN BY: <br />'Petmk to Evaavate' will be valid Far pour DIG Alert I.D. <br />CALL TOLL FREE <br />48 HOURS BEFORE YOU DIG <br />A CONGRUEX' COMPANY <br />1600 Pearl 803 Sui a 300 <br />1600 Pr, CO St - <br />APPROVED: <br />APPROVED: <br />COMCAST <br />UNDERGROUND SERVICE ALERT <br />(R4R) 211- <br />1800-422-4133 <br />APPROVED: <br />SHEET: 2 OF 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.