Laserfiche WebLink
COUNTY OF SAN JOAQUIN <br /> DEPARTMENT OF PUBLIC WORKS <br /> P.O. BOX 1810-1810 E.HAZELTON AVENUE Permit No: PS-0902177 <br /> STOCKTON,CALIFORNIA 95201 Date Issued: 10/02/2009 <br /> (209)468-3000 Exp. Date: 10/02/2010 <br /> FAX#(209)468-9324 <br /> Project No: PWP110005 <br /> APN No: 21209013 <br /> DRIVEWAY ENCROACHMENT PERMIT <br /> To: AVILA,GABRIEL B&DANA A <br /> P. O. BOX 478 <br /> TRACY,CA 95378 <br /> Location: W/S OF CARROL HOLLOW RD.600'N OF BETHANY RD. <br /> In compliance with your request of 10/02/2009,and subject to all the terms,conditions and restrictions written below or printed as general <br /> or special provisions on any part of this form. <br /> Permission is hereby granted to construct One driveway w/o pipe shown on <br /> Permit Application No. PS-0902177 Quad: SW <br /> Jobsite shall be kept in a safe condition at all times by removing daily any excess dirt or debris which might be a hazard to pedestrian <br /> and/or vehicular traffic. Adequate lights,signs and barricades shall be placed and maintained by the Permittee for the protection of the <br /> public in accordance with the current Caltrans Standard Specifications. <br /> A(n)(SEE STAMP) inside diameter per section 62 of the current Caltrans Standard Specifications,ALTERNATIVE PIPE AND PIPE <br /> ARCH CULVERTS,shall be installed in roadside drainage ditch for drainage flow maintenance and shall be of sufficient length to clear <br /> toe of approach fill or headwalls. <br /> The entire area of driveway approach(es),include flares for turning and/or paved frontage(s),from the edge of roadway pavement to <br /> right-of-way(front property)line shall be surfaced with a two inch(2")minimum of asphalt concrete over a(6 inch)Six inch minimum of <br /> compacted layer of three-quarter inch(3/4")maximum size aggregate base material(road gravel)conforming to Class 2 Aggregate Base <br /> specified in Section 26 of the current Caltrans Standard Specification,or with a four inch(4")minimum of portland cement concrete. <br /> If portland cement concrete pavement is installed,expansion joints shall be provided at the edge of pavement and along property line. <br /> Surface grades of approach(es)and/or to open ends of pipe. No ponding or puddles on pavement surface shall be allowed. <br /> The field Engineering Division of this office shall receive no less than forty-eight(48)hours notice prior to beginning of any work <br /> within the County right-of-way. After completion of the work permitted herein,all debris,lumber,barricades or any excess <br /> material shall be removed and the jobsite left in a neat workmanlike condition. The Permittee shall fill out and mail notice of <br /> completion provided by Grantor. <br /> n s : +'` I?l t„ pric" to 4)l'cup"Inc, pit.the r�4iti4 t�� E. <br /> THOMAS R. FLINN,Director <br /> Department of Public Works <br /> -tio pipe is required under and across drivcAay By '� - --- tri —.----------' <br /> _ approach at this time. However, if in the future Permit section <br /> FORMS: SS/WW,R-17 ] it is determined by the County that pipe will he <br /> required at this location,it shall be the responsi- <br /> hility of the property owner to supply needed <br /> pipe per Couaty requirements, <br />