Laserfiche WebLink
COUNTY OF SAN JOAQUIN DW EP No: DFW-05 13sE—, <br /> O �'p DEPARTMENT OF PUBLIC WORKS Date Issued: 1/20/2005 <br /> Z� P.O.BOX 1810-1810 E.HAZELTON AVENUE Expiration Date: /1/2006 <br /> STOCKTON,CALIFORNIA 95201 Job No: 111005 <br /> • (209)468-3000 <br /> �p FAX#(209)468-9324 APN No: 185-120-02 <br /> DRIVEWAY ENCROACHMENT PERMIT CR# p24000 <br /> To: PORGE SALCEDO Location: 7306 S.VAN ALLEN RD.;E/S VAN ALLEN RD. <br /> 1/2 MILE N/O GAWNE RD. ON 1/24/05 PERMIT <br /> 904 MUNFORD AVE. REQUIREMENT REVISED TO ALLOW AN 18" <br /> TOCKTON,CA. 95215 IPE. SEE ATTACHED FOR HYDRAULIC <br /> DETERMINATION. <br /> Ri <br /> In compliance with your request of 12/20/2004 ind subject to all the terms, conditions and <br /> restrictions written below or printed as general or special provisions on any part of this form. <br /> Permission is hereby granted to constuct NE DRIVEWAY APPROACH shown on <br /> Permit Application No. DW-05 T 13 E]. <br /> Jobsite shall be kept in a safe condition at all times by removing daily any excess dirt or debris which might be a hazard <br /> to pedestrian and/or vehicular traffic. Adequate lights, signs and barricades shall be placed and maintained by the <br /> Permittee for the protection of the public in accordance with the current Caltrans Standard Specifications. <br /> A(n) IEIGHTEEN ch ( 18 ') inside diameter per section 62 of the current Caltrans Standard <br /> Specifications, ALTERNATIVE PIPE AND PIPE ARCH CULVERTS, shall be installed in roadside drainage ditch for <br /> drainage flow maintenance and shall be of sufficient length to clear toe of approach fill or headwalls. <br /> The entire area of driveway approach(es), include flares for turning and/or paved frontage(s), from the edge of roadway <br /> pavement to right-of-way frontproperty) line shall be surfaced with a two inch (2") minimum of asphalt concrete over <br /> a IFOUR inimt4 Ipacted layer of three-quarter inch (3/4") maximum size aggregate <br /> base material (road gravel) conforming to Class 2 Aggregate Base specified in Section 26 of the current Caltrans <br /> Standard Specification, or with a four inch (4") minimum of portland cement concrete. <br /> If portland cement concrete pavement is installed, expansion joints shall be provided at the edge of pavement and <br /> along property line. Surface grades of approach(es) and/or to open ends of pipe. No ponding nor puddles on <br /> pavement surface shall be allowed. <br /> The Field Engineering Division of this office shall receive no less than forty-eight(48) hours notice prior to <br /> beginning of any work within the County right-of-way. After completion of the work permitted herein,all <br /> debris, lumber, barricades or any excess material shall be removed and the jobsite left in a neat workmanlike <br /> condition. The Permittee shall fill out and mail notice of completion provided by Grantor. <br /> Driveway(s) shall be complete prior to occupancy <br /> of the residence, but not to exceed expiration date. <br /> THOMAS R. FLINN, Director <br /> WHITE -Permittee Department of Public Works <br /> GOLDENROD -PWD Central File <br /> YELLOW -Field Inspection <br /> PINK -Permit Section <br /> By <br /> FORMS: R-17, SS/WW / ermit section <br /> Access\Permits\Forms\Driveway E Permit Revised 07/2000 <br />