Laserfiche WebLink
R[PER -_ - <br /> U1 COUNTY OF SAN JOAQUIN D DW-06 208 NW <br /> DEPARTMENT OF PUBLIC WORKS <br /> Date Issued: 8/28/2006 <br /> �. Z� P.O. BOX 1810-1810 E.HAZELTON AVENUE Expiration Date: 8/27/2007 <br /> STOCKTON,CALIFORNIA 95201 - <br /> (209)468-3000 Job No: 11005 <br /> ��FOKNNP FAX#(209)468-9324 APN No: 055-320-58 <br /> DRIVEWAY ENCROACHMENT PERMIT cR# 029929 <br /> To: VILA CONSTRUCTION CO. —_ - -- - <br /> Location: E/S STAR STREET APPROX.450'N/0 DE <br /> 590 S. 33 RD ST. — <br /> BROGGI RD.&S/S OF BANNER ST APPROX. <br /> — 150'E/0 STAR ST. <br /> RICHMOND, CA. 94804 <br /> In compliance with your request of 7/31/2006 end subject to all the terms, conditions and <br /> restrictions written below or printed as general or special provisions on any part of this form. <br /> Permission is hereby granted to constuct TWO DRIVEWAY APPROACHES AND CONNECT TO THE STORM <br /> shown on <br /> Permit Application No. DW-06 -208 NW j. <br /> Jobsite shall be kept in a safe condition at all times by removing daily any excess dirt or debris which might be a hazard <br /> to pedestrian and/or vehicular traffic. Adequate lights, signs and barricades shall be placed and maintained by the <br /> Permittee for the protection of the public in accordance with the current Caltrans Standard Specifications. <br /> A(n) 'SEE STAMP nch ( SEE STAMP J°) inside diameter per section 62 of the current Caltrans Standard <br /> Specifications, ALTERNATIVE PIPE AND PIPE ARCH CULVERTS, shall be installed in roadside drainage ditch for <br /> drainage flow maintenance and shall be of sufficient length to clear toe of approach fill or headwalls. <br /> The entire area of driveway approach(es), include flares for turning and/or paved frontage(s), from the edge of roadway <br /> pavement to right-of-way(front property) line shall be surfaced with a two inch (2") minimum of asphalt concrete over <br /> a FOUR minima 4 ipacted layer of three-quarter inch (3/4") maximum size aggregate <br /> ase material (road gravel) conforming to Class 2 Aggregate Base specified in Section 26 of the current Caltrans <br /> Standard Specification, or with a four inch (4") minimum of portland cement concrete. <br /> If portland cement concrete pavement is installed, expansion joints shall be provided at the edge of pavement and <br /> along property line. Surface grades of approach(es) and/or to open ends of pipe. No ponding nor puddles on <br /> pavement surface shall be allowed. <br /> The Field Engineering Division of this office shall receive no less than forty-eight(48) hours notice prior to <br /> beginning of any work within the County right-of-way. After completion of the work permitted herein, all <br /> debris, lumber, barricades or any excess material shall be removed and the jobsite left in a neat workmanlike <br /> condition. The Permittee shall fill out and mail notice of completion provided by Grantor. <br /> Driveway(s) shall be complete prior to occupancy <br /> of the residence, but not to exceed expiration date. <br /> THOMAS R. FLINN, Director <br /> WHITE -Permittee Department of Public Works <br /> GOLDENROD -PWD Central File <br /> YELLOW -Field Inspection <br /> PINK -Permit Section <br /> By <br /> FORMS: R-17, SS/WW ermit section <br /> Access\Permits\Forms\Driveway E Permit <br /> - _ _ - -+4o-pipe-is-re4uired-under-and-across -rlrt,i_e.f Revised 07/2000 <br /> approach at this time. However, if in the futui <br /> t is determined by the County that pipe will ;,, <br /> required at this location, it s;,all be the re,';.ons, <br /> Ality of the property owner to supply heed-6- <br /> pipe per County renuiren-wntti. <br />