Laserfiche WebLink
I <br /> AWG CONDUCTOR SCHEDULE <br /> OR POLE OR RUN No. <br /> CABLE 0 CIRCUIT 1 4L- A3 z4 , 5 6 7 8 9 <br /> POLE A 11-0-1 1-0-1 1-0-1 1-0-1 <br /> W POLE B 1-1-0 1-1- 1-1-0 <br /> Q Q V 3-12-28 POLE C 1-0-1 1-0-1 <br /> II i CONDUCTOR <br /> POLED 1-1-0 1-1- 1-1-0 <br /> CABLE POLE E 1-0-1 1-0- 1-0-1 1-0-1 <br /> j V_ R >4 lI/� 0 a POLE F 1-1-0 . 1-1-0 1-1-0 1-1-0 1-1- <br /> I (7 POLE G 1-0-1 1-0- 1-0-1 1-0- 1-0-1 1-0-1 <br /> 45 <br /> I I I 416U I M 20 10 0 20 40 TOTAL CABLES 8-4-4 8-4-t 4-2-2 3-1-22-1-1 1-0-1 1-1-0 2-1-1 3-2-1 <br /> Y G ;I 1"=20' GRAPHIC SCALE <br /> 2" C, 2 DLC I r��l�V� LUMINAIRE <br /> 2 2 2 2 2 2 2 <br /> 1 <br /> B I I I W /-- RL Exist. sign --,, 1 2 2 2 <br /> ! <br /> DH � �I <br /> R 117 ��, {�� �� a , �,��.. , r�_t ,9 D.L.C. 2 2 2 2 2 2 <br /> BENJAMIN HOLT DRIVE 6 © � � .� � F �� TYPE C 4 2 2 2 z z <br /> B 6P S 2 2 2 2 2 <br /> is <br /> • UM <br /> 80 TO <br /> ® y _ �.. Z" C, 5 DLC 2 2 2 <br /> IT LINE <br /> �4pPB O P 3 k ' :., . . _ ___ TOTAL D.L.C. 12 12 6 2 2 4 4 6 <br /> _ . <br /> -5 Q ::: - -. _. <br /> go 7- <br /> a . 2" C 2' C. 1 DLC —�� 2" C - <br /> 06 <br /> /Lu _ <br /> DH to <br /> SJOU ....-..._ <br /> r 6J2U <br /> SAA DH ;1 7 _ _ CONDUIT I 2-4" 2-4" 4" 4" 4" 4" 4" 4" 4" <br /> 01 •5 111 U DH 111U <br /> DHU •2 <br /> 2" C, 1 DLC 2• C. <br /> Y C. ©0 ❑ P�4ti; 6oX <br /> .__ •1 10 <br /> _ 0 i —� •4 �— ., LocnnoN STANDARD slc T ARM EQUIPMENT ETYPE SCHEDULE <br /> e <br /> •4 <br /> 2" C. 4 DLC <br /> PEO <br /> •4 - i5f � - SIGNALS SIGNAL PPB LUMINAIRE <br /> IAPB F �� SEC. MTG. MTG • ARROW WATTAGE NOTES <br /> LIMITTO _. J, I y \\ -. <br /> � F <br /> MIT LINE T►Y° INSTALL G7 "BENJAMIN HOLT DR" SIGN <br /> " • 8 1W& ' 12" MAS SP-1-T ; u 200W HPS <br /> E BJBL 2 ❑ O _ ❑ ❑ ❑ (� 19-3-SO 25' 15' <br /> O RL Exist. sign RL Exist. street light SC <br /> 8 1W3L 1RSV-1-T <br /> , <br /> 02 <br /> PPOI 2" C, P 2#10 It <br /> o DH •8P <br /> ' 0 1-8 - - 5 1W3L A,12" TV-1-T SP-I-T g RT <br /> `2" C, 2 DLC _ 5 ,W3L A,12' MAS INSTALL G7 GETTYSBURG PL SIGN <br /> © 26-4-80 40� 2 1W3L 12" MAS SP-I-T R, 'L{ 20OW HPS INSTALL R34 SIGN. <br /> 2" C. <br /> O 1-8 - - 4 1W3L 12" TV-1-T �_I_T R ;Ri <br /> LY C, <br /> yy,� C' 19 Y4' r <br /> SSSS O 19-3-80 25 151 4 1W& 12" MAS SP-I-T 2 LT 20OW HPS INSTALL G7 "BENJAMIN HOLT DR" SIGN <br /> s 4" Con to Lip of Gutter 4 1W3L tC£" SV-1-T <br /> No. 21258 - - <br /> • E9, 9-3"1 i O I-B <br /> 1 1W3L A,12" TV -T SP-1-T 4 RT <br /> CAL1F0��\e 6' Typ. all aides © 24-4-80 35' I IW& r,12" MAS 4 LT INSTALL G7 "GETTYSBURG PL" SIGN <br /> D H PROJECT NOTES 6 1 W 12" MAS SP—I—T 200W HPS INSTALL R34 SIGN <br /> 141 4" 6 IW&3L FSV-1—T <br /> O 1—B 8 1W& 12" TV—,—T SP—I—T 6 RT <br /> 1 (PGkE), 120/240, 1 PHASE, 3 WIRE SERVICE <br /> DETECTOR HANDHOLE DETAIL LOAD: TRAFFIC SIGNAL SYSTEM (120), APPROX. 2650 WATTS. (D <br /> 4-200 W. HPS LUMINARIES. P CABINET AND FOUNDATION WITH GFjQUNDING ROD, AND TYPE 90 CONTROLLER ASSEMBLY. <br /> TOTAL LOAD: 3,450 +/- WATTS. CONSTRUCT CONCRETE PAD FOR P CABINET AND SERVICE, SEE ES-4B. <br /> •gip O2 TYPE III-AF SERVICE ENCLOSURE (SEE ES-21)) <br /> f— 06 PROVIDE ITEMS , THRU 8, 15 THRU 17, AND 21 AND 22. <br /> s1 <br /> ❑3 RS FA STREET LIGHTING POLE AFTER TRAFFIC SIGNALS ARE TURNED ON. J FURNISH AND INSTALL TYPE III-AF SERVICE ENCLOSURE, SEE ES-20. <br /> 6p 04 ❑4 MODEL P CABINET WITH TYPE 90 CONTROLLER AND AUXIUARY "A" INDICATES 12" ARROW DISPLAY. <br /> st a 06EQUIPMENT TO FACILITATE THE SIX PHASE SIGNAL OPERATION. PRIOR TO <br /> a 06 4 INSTALLATION CONTRACTOR SHALL HAVE CONTROLLER TESTED AND SUPPLY THE <br /> 01 1 02 04p I 08p COUNTY OF SAN JOAQUIN CONSTRUCTION INSPECTOR WITH A CERTIFICATE OF COMPLIANCE. <br /> T JV, OS EXISTING POLE FOR ELECTRICAL SERVICE RISER. <br /> 05 or o-2p-0 RISER LOCATION ON THE POLE, SIZE AND HEIGHT SHALL MEET PACIFIC GAS AND ELECTRIC (PG&E) GENERAL NOTES : <br /> 08 SPECIFICATIONS. Qp6E�q <br /> 01 h sS � © RS FA EXISTING TYPE 1-0 POLE (TOTAL 4) AND FLASHING BEACON AFTER TRAFFIC SIGNALS ARE TURNED ON. 1. LABEL PEDESTRIAN AND SIGNAL COMMONS SEPARATELY IN I�ISIM EIB TITICA OICINEFR <br /> IS s2 do s8 14 Ac s8 IN THE CONTROLLER CABINET. No. E-6615 <br /> It•2 j F7 TEMPORARILY RELOCATE EXISTING POLE AND FLASHING BEACON. 2. INSTALL TYPE V PHOTOELECTRIC CONTROL UNIT w ~ e <br /> •2p <br /> 02 t •S RS FA EXISTING POLE AND FLASHING BEACON AFTER TRAFFIC THE SERVICE CABINET. <br /> C SIGNALS ARE TURNED ON. � � 1fo <br /> 3. FLASHING INDICATIONS SHALL FLASH RED ON ALL PHASES. 7tn1� <br /> 8 lla, P.B. <br /> Steady Demand Sequence REMOVE EXISTING OVERHEAD SERVICE FEED FOR STREET LIGHTING. 4. ALL "STOP AHEAD" PAVEMENT LEGENDS SHALL BE REMOVED, Wilbur J. EAND ALL R-1, W-17 AND W-17A STREET SIGNS, SHALL BE `�anvr4ceo 7624 WoodoldtI e rol yyDft <br /> 10 <br /> Q UNDERGROUND SERVICE FEED FOR FLASHING BEACONS. REMOVED AND SALVAGED AT SIGNAL NRN ON. <br /> 25� <br /> X16 PULLBOX W/ r SCHEDULE 80 CONDUIT AND PULLROPE IN THE SAME TRENCH <br /> AS CONDUIT RUNS 3 AND S FOR FUTURE FIBER OPTIC INTERCONNECT. <br /> 10 Rs FA EXISTING ELECTROUER AFTER TRAFFIC SIGNALS ARE TURNED ON. NOTE: THIS PLAN ACCURATE FOR ELECTRICAL WORK ONLY. <br /> DRAWN BY DATE PROJECT ENGINEER DATE CHECKED DATE SUBMITTED DATE APPROVAL RECOMMENDED DATE SHEET <br /> COUNTY OF SAN JOAQUIN 20 SCALE SIGNAL PLAN BENJAMIN HOLT DRIVE AND GETTYSBURG PLACE TRAFFIC SIGNAL NO. [SHEE% <br /> �aaua oz/oo (Intersection of Benjornin Holt Drive and Gettysburg Place) 4 6 <br /> FILE NAME DRAWER SHEET NO. I ACRD REVISIONS DATE <br /> MI Per COS 18/30/00 <br />