My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
L648 - L685
PublicWorks
>
VAULT MAPS
>
Large Plans - LP
>
Drawer L
>
L610 thru L781
>
L648 - L685
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2025 3:22:33 PM
Creation date
1/22/2016 6:29:20 PM
Metadata
Fields
Template:
Large Plans - LP
Project
Lower Sacramento Road Corridor Improvements on Woodhaven Lane, Chestnut Street, and Mokelumne Street
Limits
Woodhaven Lane, Chestnut Street, and Mokelumne Street
Year
2002
Project Engineer
M. Selling
Roads Worked
Woodhaven Ln., Chestnut St., Mokelumne St.
Red Lines
Yes
Federal #
RSTPL-5929 (143)
Supplemental fields
Classification
As-Builts
Cross Ref
L648 - L685
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
TH/S SECT/ON OF GONOU/T 70 ,615 <br /> RIG!O S'TEEG C/NT/L CO/VOU/T <br /> Q GOES Bl C.<' UNOE.P ThiE a14%g ' W,4e,/<' <br /> 3 65' t ® Q <br /> D iss <br /> I. 0 4ANE CJ i <br /> �ppflfl✓E�/ <br /> EXISTING STREETLIGHT (2) <br /> W ROUTE EXISTING 1" CONDUIT FROM STREETLIGHT (2) TO THE STREETLIGHT Construction Responsibilities <br /> JUNCTION BOX PER DETAIL. INSTALL 2-NO. 12, THHN, CU WIRES TO THE IZUI <br /> STREETLIGHT JUNCTION BOX. ROUTE EXISTING 1" CONDUIT FROM <br /> STREETLIGHT (1)TO THE STREETLIGHT JUNCTION BOX PER DETAIL. ? A. CONTRACTOR TO FURNISH AND/OR INSTALL: <br /> SAWCUT, REMOVE AND THEN REPLACE CONCRETE AT SCORELINES AS <br /> REQUIRED TO ROUTE CONDUITS. 11. All streetlight trenching, backfill and compaction. Streetlight trench depth <br /> shall be per City of Lodi, Electric Utility Department specifications. <br /> STREETLIGHT JUNCTION BOX <br /> 2. All streetlight conduit and conductors up to the streetlight junction box. <br /> INSTALL A STREETLIGHT JUNCTION BOX. BOX TO BE SET LEVEL, SIX <br /> INCHES BACK OF WALK AND 1" ABOVE ADJACENT LANDSCAPING. MAKE 13. Streetlight(s) (5) per City specifications and drawings (City of Lodi to furnish <br /> AND MOISTURE PROOF STREETLIGHT CONNECTIONS. REPLACE ( steel standards, mast arms, luminaires, lamps and photocells). <br /> STREETLIGHT WIRES FROM STREETLIGHT (1) WITH 2- NO. 12, THHN, CU 4. Make and moisture proof all electrical connections except at power source <br /> WIRES. (streetlight junction box). <br /> B. CITY OF LODI, ELECTRIC UTILITY DEPARTMENT, TO FURNISH AND/OR <br /> INSTALL: <br /> rr r <br /> Streetlight junction box and associated equipment. <br /> 2. Route conduit and conductors from existing streetlight (2) to the streetlight <br /> junction box. <br /> 4. Route conduit and conductors from the existing streetlight (1) to the <br /> streetlight junction box. <br /> STREETLIGHTING LEGEND: 3. Make and moisture proof connections at the streetlight junction box. <br /> 2 NO. 12 THHN COPPER CONDUCTORS IN 1" CONDUIT. 4. Steel standards, mast arms, luminaires, lamps and photocells. <br /> -- 2 NO. 8 THHN COPPER CONDUCTORS IN 1" CONDUIT. <br /> OVERHEAD SECONDARY BY CITY OF LODI 5. Sawcut, remove and then replace concrete as required to reroute conduits. <br /> /NSTi4LG STiPEETG/Gfi�T 0 SECONDARY SERVICE JUNCTION BOX BY CITY OF LODI <br /> S?�QEETG/GyT E3�5E �UT� c. UiAIC77401t/ bDX ® STREETLIGHT JUNCTION BOX. <br /> 11V7-0 671-,PE 7ZI45 7T ./UrVCTian/ a POLE-MOUNT TRANSFORMER, BY CITY OF LODI. <br /> LQOX <br /> PAD-MOUNT TRANSFORMER, BY CITY OF LODI. <br /> -7E'E4 (:ZZI- L:1J/T STANDARD WITH LUMINAIRE ON 8' ARM. NOTE: <br /> STANDARD WITH POSTI TOP LUMINAIRE. 1. Luminaires to be 208 Volt Type III with integral regulated ballast and <br /> ST� '._C"'TG/GHT ,l3f/SE Ophotoelectric cell. <br /> _ A 10OW HIGH PRESSURE SODIUM ON STEEL STANDARD. 2. Standards to be galvanized steel. <br /> B 25OW HIGH PRESSURE SODIUM ON STEEL STANDARD. 3. All materials are subject to approval by the City of Lodi, Electric Utility <br /> C 100W HIGH PRESSURE SODIUM ON WOOD POLE, BY CITY OF LODI. Department, prior to installation. <br /> 4. Installation shall conform to City of Lodi, Electric Utility Department <br /> D 250W HIGH PRESSURE SODIUM ON WOOD POLE, BY CITY OF LODI. 4. <br /> except as noted on plans. <br /> G IOOW HIGH PRESSURE SODIUM POST TOP LUMINAIRE ON 12' DECORATIVE STANDARD. 5. Streetlight installation to be inspected by the City of Lodi, Public Works <br /> H 70W HIGH PRESSURE SODIUM POST TOP LUMINAIRE ON 10' CONCRETE STANDARD. Department. <br /> E EXISTING. 6. The Contractor shall do no excavating until all utility agencies hove been <br /> F FUTURE. given the opportunity to mark their facilities in the field. <br /> 7. Allen type flat head screws shall!be used to attach hand ho;d covers to <br /> S9/,UCUT ?EMDI/ • WOOD UTILITY OLE WITH RISER. standards. Screws shall be galvanized or equivalent. <br /> CGYVC.�LTF /17— TYPE OF LIGHT FIXTURE. 8. Lights installed on a curved alignment shall be perpendicular to the center line <br /> 5C„<ye!51_/NES 1#5 of the street. <br /> 9. Installation shall be in accordance with the Manufacturer's published <br /> installation procedures unless otherwise noted. <br /> 5/DEjIlf/LK 10. Mount the photoelectric control unit with the light sensor facing North. <br /> CURB <br /> GUTTER <br /> /it/Ta -57R" 4�ETL /Gf17 JUNCT/ON aDX. <br /> .PE�L�CE s .-.Qe TG/GtfT Wi eE To <br /> L IC--4,417-1-95 <br /> C'OiV/DU/T/NS5Z4_ 441tT/GYV 1�ETf4/L <br /> APPROVED BY TITLE W.O. 206 <br /> . � . CITY OF LODI i�WAE5o Z5S7R_ 161417 W.O. <br /> ELECTRIC UTILITY DEPARTMENT 'r/z <br /> r� GRID S' <br /> q � � D�/02�02 �..��.._ /�/✓C�r LA/VE 7O- WI / ,CO CA/Vi91 L SCALE <br /> c�F•� '�c"0�� DATE DRAWN CHECKED =SBILT <br /> rSHEET36 of */0:J <br />
The URL can be used to link to this page
Your browser does not support the video tag.