My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
T299 - T359
PublicWorks
>
VAULT MAPS
>
Large Plans - LP
>
Drawer T
>
T299 thru T368
>
T299 - T359
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2016 3:38:44 PM
Creation date
1/22/2016 9:08:46 PM
Metadata
Fields
Template:
Improvement Plans
Supplemental fields
DocCategory
Improvement Plans
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DIST COUNTY ROUTE KILOMETER POST SHEET TOTAL <br /> TOTAL PROJECT No SHEETS <br /> CONDUCTOR AND CONDUIT SCHEDULE 10 Si 12 15.8/17.1 541 61 <br /> AWG SIZE OR PHASE POLE OR CONDUIT SIZE AND RUN NUMBERS pC� ,G�" Z- o6-of pFESS/ <br /> CABLE SIZE CIRCUIT Q QA <br /> ® A A Q ric REGISTERED CIVIL ENGINEER DATE �� PR W w OHq` <br /> F <br /> , <br /> x POLE A 1 -0-1 1 -0-1 kA! <br /> POLE B 0-1 -0 0-1 -0 3- 16 -of G a m <br /> 3/9/12 WIREPOLE C 1 -0-1 1 -0-1 PLANS APPROVAL DATE W. No C53755 <br /> CONDUCTOR <br /> SAN JOAQUIN COUNTY Exp. CIVIL 03 <br /> POLED 0-1 -0 0-1 -0 0-1 -0 s <br /> CABLE 1810 E. HAZELTON AVE Tqr CIVIL <br /> POLE E 1 -0-1 1 -0-1 1 -0-1 1 -0-1 POLE AND EQUIPMENT SCHEDULE STOCKTON, CA 95201 FOF CAL�F� <br /> POLE F 0-1 -0 0-1 -0 0-1 -01 STANDARD VEH SIG MTG PED SIGNAL PPB HPS OMNI—MEANS, LTD. <br /> TOTAL CABLES 0-1 -0 1 -1 -1 3-3-3 0-1 -0 2-1 -2 1 -1 -1 1 -0-1 NO. TYPE Sig. M.A. um. M.A. Mast Arm Pole 0 MTG b ARROW LUMINAIRE SPECIAL REQUIREMENTS 2237 DOUGLAS BLVD. #100 <br /> A 26-4-129 12.2m 4.6m MAS SV-2—T 20OW INSTALL R-19 AND EVC ON SMA ROSEMLLE, CA 95661 <br /> NO. 8 AWG Intersection Ltg 2 2 2 2 2 The State of California or its officers or agents shall not be responsible <br /> © TYPE 15 4.6m SV-1 —T 20OW for the accuracy or completeness of electronic copies of this plan sheet. <br /> } W No, 6 AWG Highway Ltg 2 2 2 2 © 19-3-129 9.1m 4.6m MAS SV-2—T 20OW INSTALL R-19 AND EVA ON SMA <br /> M Signal Service 2 <br /> o w O 1 —A TV-1 —T <br /> W <br /> Ph2 6 6 6 6 O TYPE 15 4.6m SV-2—T 20OW <br /> o DETECTOR Ph4 6 6 <br /> x LOOP Ph6 6 6 1 — ° TV-1 —T <br /> CABLE (D <br /> o TYPE B 1 —E 1 1 © TYPE 9 FLASHING BEACON (RELOCATED) <br /> 2—E 1 1 CANTILEVER <br /> TOTAL DLC 8 20 6 6 6 6 EQUIPMENT NOTES: <br /> m ALL SIGNAL HEADS SHALL BE 300mm (12"). <br /> W o 12 Pair #20 Cable SIC 1 1 <br /> Dz `L <br /> EV PREMT EVA 1 1 <br /> v wo v CABLE EVC 1 1 Single—phase 1 3 <br /> TOTAL CABLES 1 2 1 1 1 secondary, 120/240v 3 ---- SN 4 <br /> wire service by the <br /> CONDUIT SIZE Meter A <br /> mm 53 78 2-103 78 103 78 78 serving utility - <br /> CONDUIT FILL % 11 % 22% 18% 16% 17% 21 % 14% 2 <br /> 3 3 <br /> 4 <br /> Ground lug <br /> X0 o Meter B <br /> bonded to <br /> service <br /> MO g cabinet <br /> OQ 3 SN 7 <br /> Z m I <br /> QUS 8 <br /> J <br /> W Q 21 <br /> O <br /> ;----- � I ------�SN <br /> j_____ __4_______, To test switch <br /> mounted on lighting <br /> standard, sign post <br /> 0 I I struc <br /> TYPE III—C SERVICE (120/240 V) EQUIPMENT LEGEND 15 - 15 16 IAuto 5 or requiredture when <br /> ITEM COMPONENT NAME PATE DESCRIPTION I <br /> TEM <br /> N0. NO COMPONENT NAME PATE DESCRIPTION 1 x x SN <br /> 1 NETURAL LUGSignals <br /> 13 I I— [240V <br /> 120V Si nals ace ighting <br /> 14 30 A, 240 V, 2P, CB INTERSECTION LIGHTING g <br /> 120V Flashing Beacon <br /> 0 2 LANDING LUG 15 100 A, 240 V,2P, CB MAIN BREAKER Space = Space 10 <br /> I cc 3 TEST BYPASS FACILITY 16 . 30 A, 240 V, 2P, CB LIGHTING Space • Space <br /> C 4 METER SOCKET AND SUPPORT 17150 A, 120 V,1 P, CB SIGNALS Space Space SN <br /> x 5 TERMINAL BLOCKS 18 S ace <br /> - o-- <br /> P <br /> S <br /> 6 SOLID NEUTRAL TERMINAL STRIP 19 Space 14 Auto 5 <br /> I <br /> 7 GROUND LUG 20 15 A ,120 V, 1P, CB LIGHTING CONTROL x x SN <br /> 0 8 GROUND ROD 21 PHOTOELECTRIC UNIT TYPE V <br /> F--�— 240V <br /> z 9 30 A, 2PNO, CONTRACTOR INTERSECTION LIGHTING 22 15 A, 1P, TEST SWITCH LIGHTING CONTROL — — Lightsngtion <br /> LU 10 PHOTO ELECTRIC UNIT TYPE V 23 60 A, 2PNO, CONTRACTOR LIGHTING <br /> 11 15 A, 1P, TEST SWITCH INTERSECTION LIGHTING TEST SWITCH 24 <br /> LU 12 15 A, 120 V, 1P, CB INTERSECTION LIGHTING CONTROL 25 <br /> 13 15 A, 120 V, 1P, CB FLASHING BEACON 26 SOUTHBOUND OFF RAMP FROM 1-5 TO SR-12 <br /> SERVICE WIRING DIAGRAM <br /> Z1z�10 3 <br /> z CHANGE NAME PLATES TO LETTERING AS SHOWN. <br /> 0 <br /> SUPPLY ALL EQUIPMENT REQUIRED FOR DUAL METERING. <br /> J SERVICE WIRING DIAGRAMS ARE SITE SPECIFIC. <br /> U <br /> SIGNAL & LIGHTING <br /> U_ <br /> x <br /> CONDUCTOR TABLES & DETAILS <br /> W <br /> a <br /> SB RAMPS/ROUTE 12 <br /> cn NOT TO SCALE o <br /> ALL DIMENSIONS ARE IN - <br /> E2 <br /> THIS PLAN ACCURATE FOR ELECTRICAL WORK ONLY METERS UNLESS OTHERWISE SHOWN C L o <br /> N <br /> O <br /> FOR REDUCED PLANS ORIGINAL DRAWN BY: E. MORRIS <br /> SCALE IS IN MILLIMETERS l i 21 i 41 i sl i 81 DWG FILE: 040EO2CU 06241 EA 456001 <br />
The URL can be used to link to this page
Your browser does not support the video tag.