My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
W419 - W450
PublicWorks
>
VAULT MAPS
>
Large Plans - LP
>
Drawer W
>
W393 thru W504
>
W419 - W450
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2016 3:38:53 PM
Creation date
1/22/2016 10:07:44 PM
Metadata
Fields
Template:
Improvement Plans
Supplemental fields
DocCategory
Improvement Plans
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
f' REG No.I STATE I 1- VLKAL YKUJLI-1 NU. YEAR No. SHEETS I <br /> 7 CALIF. <br /> DIST. COUNTY ROUTE SECT!0N SHEET TOTAL <br /> HoSHEETS <br /> X S✓ 906 3.3 � 3-� <br /> SYMBOLS APPROVED FEBRUARY /964 <br /> X PROPOSED EXISTING <br /> TRAFFIC GI EER, REGISTERED C. E. N0. @5@6 <br /> T- -0 Q-- Ultra-sonic detector (Side fire type) <br /> --♦ ---:� Impact detector CO TO ACCOMPANY PLANS DATED <br /> E=3 `, <br /> �__J- /. Unless otherwise indicoted,conduit in service and detector runs shalt be <br /> Inductive loop detector <br /> Non-directional pressure detector / inch and all other conduit shall be 1-/12 inch. <br /> MMD 0-=3MD Non-directiono/ magnetic detector 2. Conduit shall be installed /8"minimum below curb grade in sidewalk areas <br /> o r- Directional pressure detector and 30 minimum below grade or finished surface /n o// other areas except <br /> `1`- Tioffic signo/ with o// co/ors louvered that conduit installed within curbed dividing strips constructed on existing <br /> -- � Traffic signal each arrow one-way three color pavement may be /aid on and secured to the pavement. <br /> �o specified) <br /> (On Type I-A standard unless otherwise spec <br /> 3. Conduit runs parallel to curbs shall be placed adjacent to bock of curb, except <br /> .4 -0 ;-- Traffic signal one way three co/or with backp/ote where in conflict with existing facilities. Minimum depth shall be /2 inches. <br /> (On Type l-A standard unless otherwise specified) 4. Existing underground conduit to be incorporated into new systems shall be <br /> {'-- <br /> .. Traffic signal one way three-color with green arrow cleaned with o mandrel and blown out with compressed air <br /> (On Type I standard unless otherwise specified. Red <br /> and yellow louvered.) 5. Conduit terminating in standards and pedestals shall extend 2"max. above SIGNAL EQUIPMENT <br /> m----� «;--- <br /> Walk-Don t Wo/k pedestrian signal (7" Type I standard unless finished top of foundation and shall slope toward the handhole. <br /> indicated.) 6. Conduit entering controller cabinets shall be sealed with paraffin or other I. Vehicular and pedestrian signal mountings shall be oriented so as to provide <br /> otherwise <br /> Pedestrian signal,2 co/or head. (Existing), approved sealing compound. maximum horizontal clearance to adjacent roadway. <br /> 9 , <br /> 7. Service risers shall be terminated with o service head and shall be sea/ed to <br /> X <br /> -- -<= Most arm troffic signo/withbockp/ate (On Type standard) prevent the entrance of water, as approved by the serving utility. <br /> yam(v-70 '1 ' '' ER <br /> E/ectrolier,most arm type with most arm traffic ELECTROLI <br /> signal with backplate (Type.7 standard) <br /> /. A mercury-vapor /amp ballast shall be installed in o pull box adjacent to each <br /> ----o -- E/ectrolier, most arm type (Type% standard) <br /> PULL BOXES electro/ier, unless integral ballast type luminaires are used. <br /> E/ectrolier, upright type <br /> ppg Ppb Pedestrian push button /. Pull boxes shall be No. 5 except as noted. <br /> 0 PPB Q%PVb Pedestrian push button on special push button post. <br /> -0- -0- Telephone pole <br /> �• Power pole FOUNDATIONS <br /> IR Flashing beocon,one-way CONDUCTORS ANp WIRING . <br /> -�- -b- Fire hydron t / Signa/ neutral shall be #/0 AWG conductor <br /> /. Top of foundations for standards shall be /eve/ with top of curb in curbed <br /> -- -- —-- —- Overhead conductor # areas or 6 inches above surrounding grade in other areas. <br /> __— -- Signa/ conduit ' 2. Conductors between ballasts or transformers and /uminoires sho// be /O AWG, <br /> — —— --- L i 9 9 htin conduit 600 volt. 2. Except as indicated, standards shall be instal/ed with 2 foot clearance to face <br /> �� 3. Conductors between series-to-multiple transformers and sign fixture ballasts of curb, edge of shoulder, bock of dikes, and bock of ditches. <br /> o Pull box shall be /2 AWG, 600 volt or larger. <br /> Controller 4. Number of conductors indicated in signal system conduit includes three #/4 <br /> Q Flush soffit luminaire, Detail �F,7(arrow indicates AWG spares. <br /> astreet side) 5. Conductors shall be identified with bonds. <br /> 4 Pendant soffit luminaire, Detail "P,"(arrow- street"side) 6. Underground conductors to signals shall be run without splices, except that where <br /> modified si <br /> existing signals ore being , nal conductors may be spliced where 9 <br /> � •xx i/ „W „ indicated. <br /> -� Wall-mounted luminaire, Detail f <br /> 7. Neutral conductors may be spliced in pull box. <br /> * *` 7,000-lumen,mercury-vapor,ballast in closest pull box unless <br /> /lasts ore specified. 8. Two feet of slack shall be provided in each conductor in each pull box. <br /> Integra/ bo P <br /> 9. A separate conductor, other than neutral, shall be run from each pressure <br /> detector to controller cabinet. <br /> l0. Connection to each terminal of a pedestrian push button shall be by a <br /> single conductor . Splices shall be made in nearest pull box. ` <br /> It Color coding for wiring to pedestrian signals shall be as specified for p <br /> corresponding vehicular green and red indications. AS <br /> 12. One side of secondary circuit of series-to-multiple and step down transformers shall be <br /> grounded. On structures the grounding electrode shall be the conduit CORRECTIONS BY <br /> system. Off structures, it shall be 112" x 8 ground rod installed through NO CHANGES �,�• <br /> bottom of pull box. DATE _ ZS_ �,S - -- <br /> COPY <br /> a,Nt <br /> Typical Markings <br /> Circuit (/ Bond) <br /> Equipment location <br /> number (l or 2 Bonds) <br /> _ Phase (l or 2 Bonds) <br /> End of conductor t r D 4 B 1 10 - 101554 <br /> B-/ Phase <br /> Detector location as <br /> shown on plan STATE OF CALIFORNIA <br /> DEPARTMENT OF PUBLIC WORKS <br /> Detector circuit DIVISION OF HIGHWAYS <br /> TYPICAL BANDING OF CONDUCTOR ENDS <br /> STANDARD DETAILS N0. 4 <br /> TRAFFIC SIGNAL AND <br /> HIGHWAY LIGHTING <br /> INSTALLATIONS <br /> SCALE AS NOTED <br /> Revised <br /> ,,zI8 ,963 ,,L • DRAWING N 0. E- <br /> ES - 4 -3 <br /> PROJECT ENGINEER DATE DESIGN ENGINEER DATE APPROVAL RECOMMENDED BY DATE <br />
The URL can be used to link to this page
Your browser does not support the video tag.