AARON CARDWELLDESCRIPTIONDATE REVSheet Title:Sheet Size:Sheet Number:Project:PERMIT SET12/31/2019AREVISIONSProject Details:DESIGN & DRAFTING BY:Reviewed & Approved by:CMSepiSolar ® POWER BY DESIGN ®SepiSolar ® POWER BY DESIGN ®SepiSolar ® POWER BY DESIGN ®SepiSolar ® POWER BY DESIGN ®Contractor:SOLAR LIGHT POLE3222 COLLIER RD. EASTPV ARRAY: 550 WBATTERY BANK: 224 Ah, 5.4 kWACAMPO CA 95220ANSI B - 17" x 11"E1.0(N) CHARGE CONTROLLERSEPCO MPPT2MAX PV VOLTAGE: 85 VDCBATTERY VOLTAGE: 12-24 VDCMAX CHARGE/LOAD CURRENT: 20 APVINPUTGBATTERYCONN.LOADOUTPUT12V12V(N) BATTERY BANK TYP. OF 4(2) BATTERIES IN SERIES(2) SETS OF (2) BATTERIES IN PARALLEL224 Ah, 24 VDC, 5.4 kWUL LISTED12V12VDC1(2) 275 W PV MODULES(1) 224 Ah BATTERY BANK(1) SEPCO MPPT2 MAXIMUM POWER POINT TRACKER(1) POWER BRACKET MOUNT (45D)GG2 1PV MODULE (QTY 2)RATED POWER: 275 W(N) PV POWER ASSEMBLY POLE4" SCH40 GALV. STEEL PIPE(N) VENTED ALUMINUM ENCLOSUREWITH POWER BRACKET"THROUGH THE POLE"ROUTING OUTPUTGROUND LEVEL(N) TYPE 15 POLE12-14 FT. MAST(N) SEPCO SEPA550-QM ASSEMBLYDC SOLAR POWERED LIGHT FIXTURELED LIGHT SOURCE54 W, 12 VDC, 4.5 A(N) VIPER FIXTURE1211280.0%70.04Ah rating (Ah, 20 hour):Max Depth of Discharge:Model Number:Voltage (VDC):Weight (lbs):Battery Quantity:Deka Battery Specifications2420241Model Number:Max PV Voltage (VDC):Battery Voltage (VDC):Charge Controller SpecificationsSepco MPPT2 Load ControllerMax Output Current (A):CC Quantity:Model Number:Weight (lbs):20.0Dimensions (in):Power @ STC (W):275Voc (VDC):34.0Vmp (VDC):32.0Voc Temp Coeff (%/°C):-0.30Isc (A):20.00Max Voltage (VDC):600Imp (A):20.00Module Quantity:2SEPA550 PV Module Specifications80L X 66W X 2.1DWIRE AND CONDUIT SCHEDULETAGCONDUIT SIZECONDUIT TYPEEST.DIST.DC13/4" SCH40 PVC 2 AWG #14 THWN-2 N/A N/A N/A N/A N/A N/A 15PHASE CONDUCTORQTY, SIZE AND TYPEPER CONDUITGROUND CONDUCTOR QTY, SIZE AND TYPEPER CONDUITNEUTRAL CONDUCTOR QTY, SIZE AND TYPEPER CONDUITLocal Record Low Temp:°CData Source: 0.3%/°C x 28°C + 1 =1.084 x 34.0 x 2 =73.7Volts DC1+-31.084Voc Temp CoefficientxPV System Maximum Voltage Calculation per NEC 690.7(A)STOCKTON METROPOLITAN ARPT=Voc Correction FactorVoc Correction FactorxVocxMax # of Modules in Series25°C - Record Low Temp.=Temperature Corrected Open Circuit Voltage CONDUIT FILL DERATING VOLTAGE DROPMATERIALCONN. TEMP. RATINGTRADESIZEMAX CURRENT 690.8(A)(1)xI (Amps)x# OF COMBINED STRINGS=xCONT. OPERATION 690.8(B)(1)=<CIRCUIT ENVIRONMENTLOCAL 2% AVG. HIGH TEMP (°C)HEIGHT ABOVE ROOF (in)TEMP. ADDER PER310.15(B)(3)(c)EXPECTED OPERATING TEMP (°C)AMPACITY CORRECTION310.15(B)(2)(a)# OF UNGROUNDED CONDUCTORSAMPACITY CORRECTION 310.15(B)(3)(a)90°C CONDUCTOR AMPACITYxTEMP DERATExCONDUIT FILL DERATE=<VOLTAGE DROPDC1PV POWER POLE TYPE 15 POLECOPPER 90°CAWG #14 25Amps1.25 x 4.50 x 1 = 5.6Ampsx 1.25 = 7.0Amps7.0Amps<25.0AmpsUNDERGROUND (+0°C)38 - N/A 38 0.91 N/A 1.00 25 x 0.91 x 1.00 = 22.8Amps5.6Amps<22.8Amps15ft0.90%MAX CURRENT PER 690.8(B)(1)MAX CURRENT PER 690.8(B)(1) REQUIRED CONDUCTOR AMPACITYCONDUCTOR AMPACITYAMPACITY CHECK #1TAG CIRCUIT ORIGINCIRCUIT DESTINATIONMAX CURRENT PER 690.8(B)(2)DERATED CORRECTED AMPACITYEST.ONE-WAY DISTANCEAMPACITY CHECK #2CONDUCTOR SPECIFICATIONSCONDUCTOR TEMPERATURE DERATINGCORRECTED AMPACITY CALCULATIONAMPACITY PER 310.15(B)(16) & 310.15(B)(17)MAX CURRENT PER 690.8(A)(1)DERATED CONDUCTOR AMPACITY