My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2800 - Aboveground Petroleum Storage Program
>
PR0516198
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 2:57:11 PM
Creation date
8/24/2018 6:23:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0516198
PE
2832
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0516198\COMPLIANCE INFO 2000 - 2016 .PDF
QuestysFileName
COMPLIANCE INFO 2000 - 2016
QuestysRecordDate
12/19/2017 10:45:19 PM
QuestysRecordID
3750331
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department °IR QonnaH <br /> Heran, REHS <br /> 600 East Main Street <br /> PROGRAM COORDINATORS <br /> �u { Stockton, California 95202-3029 Margaret Lagono, RFHS <br /> • Robert McClellon, REHS <br /> Jeff Carruesco, REHS,RDI.��!��- Website: www.sjgov.org/ehd Kasey Foley, REHS <br /> September 15, 2010 Phone: (209} 468-3420 <br /> Fax: (209) 464-0138 <br /> Greg Kaiser <br /> Kaiser Commercial Petroleum <br /> PO BOX 1058 <br /> Linden, CA 95236 <br /> Re: Jimco Truck Plaza SR0060216 <br /> 1022 E Frontage Road Addendum <br /> Ripon, CA 95336 <br /> The San Joaquin County Environmental Health Department (EHD) has completed the review of <br /> the application for a permit to replace existing secondary containment test boots on the diesel <br /> product lines in sump #3, known as pipe run 3 and 4, on the underground storage tank (UST) <br /> system at the above noted address. <br /> An inspection was performed on August 26, 2010. It was found that pipe run 4 passed the one <br /> hour pressure test and sump 3 passed the Caldwell hydrostatic test. Pipe run 3 was unable to <br /> hold pressure and future investigation was needed for the source of the leak. <br /> Addendum to the application for permit to excavate two 3x10 foot areas on pipe run 3, one at <br /> approximately 90 feet and the other approximately 20 feet from the south end of sump 3, to <br /> repair and replace the 6" secondary containment piping and 6" sleeve coupling. After the <br /> installation, a retest with nitrogen gas will be conducted to find other leaks. <br /> The permit has been approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control <br /> District for any applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval <br /> prior to commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Thuy Tran at (209) 468-8257 to arrange the following inspection appointments <br /> (a 48-hour notice is required for inspection appointments). Please be aware that <br /> inspections for emergency work must be scheduled within five days of permit approval. <br /> a. Secondary piping soap test on pipe run 3: One hour pressure test per manufacturer's <br /> guidelines. If there are no manufacturer's guidelines, test shall be performed using <br /> an applicable method specified in an industry code or engineering standard. <br /> b. Primary piping soap test: One hour pneumatic pressure test at 110% of operating <br /> pressure, or 40 psi, whichever is greater. <br />
The URL can be used to link to this page
Your browser does not support the video tag.