My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2800 - Aboveground Petroleum Storage Program
>
PR0516198
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 2:57:11 PM
Creation date
8/24/2018 6:23:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0516198
PE
2832
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\F\FRONTAGE\1022\PR0516198\COMPLIANCE INFO 2000 - 2016 .PDF
QuestysFileName
COMPLIANCE INFO 2000 - 2016
QuestysRecordDate
12/19/2017 10:45:19 PM
QuestysRecordID
3750331
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siciov.org/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GEMCO RIPON TRUCK PLAZA INC 1022 E FRONTAGE RD, RIPON October 10, 2017 <br /> SPCC Plan Requirements for Onshore Facilities(excluding production facilities) <br /> 703 CFR 112S(b)(3), Failed to design facility drainage system from undiked areas to retain in the facility o V o R o COS <br /> 112.8(b)(4) <br /> 704 CFR 112.8(b)(5) Failed to provide two In pumps for more than one continuous treatment unit o V in R to COS <br /> 705 CFR 112.8(c)(1) Container not compatible with oil stored and/or storage conditions o V o R o COS <br /> 706 CFR 112.8(c)(2) Failed to provide and maintain adequate secondary containment .V .R n COS <br /> 707 CFR 112.8(c)(3) Failure to follow the criteria of this section while allowing drainage of uncontaminated rainwater o V o R in COS <br /> 708 CFR 112.8(c)(3)(ty) Failed to maintain records of drainage from diked areas o V o R a COS <br /> 709 CFR 112.8(c)(5) Failed to provide corrosion protection for partially buried tanks o V c R o COS <br /> 710 CFR 112.8(c)(6) Plan failed to adequately discuss procedures to test or inspect each container for integrity a V .R in COS <br /> 711 CFR 112.6(c)(6) Failed to perform scheduled tank tests or inspections by appropriately qualified personnel o V o R in COS <br /> 712 CFR 112.8(c)(6) Failed to test or inspect each container for integrity based on industry standards .V a R o COS <br /> 713 CFR 112s(c)(7) Failed to provide effective leakage control from defective internal heating calls o V OR o COS <br /> 714 CFR 112.8(c)(8)(i-iv) Failed to provide each container with a high level monitoring device .V OR o COS <br /> 715 CFR 112.8(c)(8)(v) Failed to regularly test liquid level sensing devices to ensure proper operation .V .R o COS <br /> 716 CFR 112.8(c)(9) Failed to observe effluent treatment frequently enough to detect potential discharge o V o R o COS <br /> 717 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas .V .R o COS <br /> 718 CFR 112.8(c)(11) Failed to provide sufficient secondary containment capacity for mobile or portable containers .V in R a COS <br /> 719 CFR 112.8(c)(11) Failed to locate mobile or portable containers to prevent discharge o V in R o COS <br /> 720 CFR 112.8(d)(1) Failed to take corrective action on buried piping when exposed for any reason in V in R in COS <br /> 721 CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping o V o R in COS <br /> 722 CFR 112.8(d)(2) Failed to cap/blank-flange connection at transfer point and mark its origin Knot in service o V o R in COS <br /> 723 CFR 112.8(4)(3) Failed to design pipe supports to minimize abrasion/comosion and to allow for expansion/contraction o V o R o COS <br /> 724 CFR 112.8(4)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances I a V to R o COS <br /> 725 CFR 112.8(d)(4) Failed to conduct integrity and leak testing on buried piping any time it is worked on a V .R o COS <br /> 726 CFR 112.8(d)(5) Failed to adequately warn vehicles entering facility to protect piping and other transfer operations a V o R o COS <br /> Other Violations <br /> 4010 See below Unlisted Administration/Documentation violation .V OR o COS <br /> 4020 See below Unlisted Training violation o V o R in COS <br /> 4030 See below Unlisted Operations/Maintenance violation o V OR o COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ^V o R c COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> FA0000650 PRO516198 SCO01 10/10/2017 <br /> EHD 28-01 Rev.09/22/16 Page 3 of 11 Aboveground Petroleum Storage Act OR <br />
The URL can be used to link to this page
Your browser does not support the video tag.