My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
8925
>
2800 - Aboveground Petroleum Storage Program
>
PR0528878
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2019 3:27:49 PM
Creation date
8/24/2018 7:30:58 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0528878
PE
2832
FACILITY_ID
FA0017954
FACILITY_NAME
RAMOS OIL CARD LOCK
STREET_NUMBER
8925
Direction
W
STREET_NAME
THORNTON
STREET_TYPE
RD
City
THORNTON
Zip
95686
APN
00120078
CURRENT_STATUS
01
SITE_LOCATION
8925 W THORNTON RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
FRuiz
Supplemental fields
FilePath
\MIGRATIONS\T\THORNTON\8925\PR0528878\COMPLIANCE INFO 2016 - PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
12/22/2016 7:06:53 PM
QuestysRecordID
3287668
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WO <br /> San Joaquin County 40 <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> RAMOS OIL CARD LOCK 8925 W THORNTON RD, THORNTON January 27, 2016 <br /> SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br /> 723 CFR 112.8(d)(1) Failed to provide corrosion protection for buried piping ■V c R c COS <br /> 724 CFR 112.8(d)(2) Failed to cap/blank-flange connection at transfer point and mark its origin if not in service ❑V o R ❑COS <br /> 725 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contraction ❑V ❑R ❑COS <br /> 726 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping,and appurtenances ■V o R ❑COS <br /> 727 CFR 112.8(d)(4) Failed to conduct integrity and leak test on buried piping any time it is worked on ■V o R o COS <br /> 728 ICFR 112.8(d)(5) Failed to adequately warn vehicles entering facility to protect piping and other transfer operations ■V ❑R ❑COS <br /> Other Violations <br /> 4010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 4020 See below Unlisted Training violation ❑V ❑R ❑COS <br /> 4030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 4040 See below Unlisted Release/Leaks/Spills violation ❑V PR c COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by February 26th, 2016 . <br /> Please be aware as of January 1, 2013, all businesses are required to submit all new (or any changes to <br /> existing) Aboveground Petroleum Storage Act (APSA) information online to the California Environmental <br /> Reporting System (CERS) at http://cers.calepa.ca.gov in addition to any other relevant activities and required <br /> fields. No later than January 1, 2014, all APSA data must be entered and or updated in CERS. <br /> Documents reviewed: SPCC Plan <br /> Documents provided: Return to Compliance Certification Form, Schedule of Free CUPA Classes <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> T IS <br /> FACILkTY IS SU ECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received By Received By(printed name and title): Da <br /> (signature): Joy Kachadorian, EH Manager (P <br /> Inspector Inspector(printed name and title): Inspector Phone: <br /> (signature STACY RIVERA, Senior REHS (209) 468-3440 <br /> ci Page 3 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.