Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sioov.org/ehd <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> RAMOS OIL CARD LOCK 8925 W THORNTON RD, THORNTON May 10, 2017 <br /> General Requirements for SPCC Plans <br /> 601 CFR 112.7 Failure of Plan to fulfill basic requirements including a cross-referencing section V R u COS <br /> 602 CFR 112.7(a)(2) Plan failed to discuss equivalent environmental protection,if applicable -V o R ❑COS <br /> 603 CFR 112.7(a)(3) Failed to adequately describe the physical layout of the facility in the Plan D V ❑R ❑COS <br /> 604 CFR 112.7(a)(3)(i) Plan failed to include oil type and storage capacity for each container 2 V ❑R ❑COS <br /> 605 CFR 112.7(a)(3)(ii) Plan failed to adequately discuss discharge prevention measures,including routine handling V ❑R ❑COS <br /> 606 CFR 112.7(a)(3)(iii) Plan failed to adequately discuss facility drainage or drainage controls V ❑R ❑COS <br /> 607 CFR 112.7(a)(3)(iv) Plan failed to include countermeasures for discharge discovery,response and cleanup D V n R ❑COS <br /> 608 CFR 112.7(a)(3)(v) Plan failed to address disposal methods for recovered materials n V ❑R ❑COS <br /> 609 CFR 112.7(a)(3vi), Plan failed to adequately contain procedures for reporting a discharge 3 V ❑R ❑COS <br /> 112.7(a4) <br /> 610 CFR 112.7(a)(5) Discharge procedures are not adequately addressed if the facility has no response plan j V ❑R ❑COS <br /> 611 CFR 112.7(b) Plan failed to include a description of potential equipment failure or provide equivalence V ❑R ❑COS <br /> 612 CFR 112.7(c) Plan failed to include secondary containment,diversionary structures,or equip to prevent discharge V ❑R ❑COS <br /> 613 CFR 112.7(c) Failure to provide appropriate secondary containment,diversionary structures or equipment j V u R ❑COS <br /> 614 CFR 112.7(d) PE certified Plan failed to explain impracticability of containment/diversionary structures 3 V ❑R u COS <br /> 615 CFR 112.7(d) Failure to perform integrity and leak testing when claiming secondary containment impracticability V ❑R in COS <br /> 616 CFR 112.7(d)(1) Failure to prepare an all spill contingency plan when claiming impracticability of structures V ❑R ❑COS <br /> 617 CFR 112.7(d)(2) No written commitment of manpower,equipment,and materials to control and remove oil discharge n V ❑R ❑COS <br /> 618 CFR 112.7(e), 112.8(c) Failed to conduct inspections or integrity tests or maintain records for 3 years V ■R ❑COS <br /> 6 <br /> 619 CFR 112.7(f)(1) Failed to train personnel on discharge prevention V ■R ❑COS <br /> 620 CFR 112.7(f)(2) Failed to designate a person accountable for discharge prevention V u R n COS <br /> 621 CFR 112.7(f)(3) Failed to schedule and conduct discharge prevention briefings at least annually V ❑R ❑COS <br /> 622 CFR 112.7(f)(3) Failure to conduct spill prevention briefing for oil-handling personnel n V u R ❑COS <br /> 623 CFR 112.7(g) Plan failed to address security of site and valves,lock outtlag out,and lighting D V n R ❑COS <br /> 624 CFR 112.7(g) Facility failed to implement security of site and valves,lock outftag out,and lighting j V ❑R ❑COS <br /> 625 CFR 112.7(h) Plan failed to adequately discuss facility tank car and tank truck loading/unloading rack 3 V ❑R ❑COS <br /> 626 CFR 112.7(h)(1) Loading/unloading rack containment system not adequate to contain spill 3 V ❑R u COS <br /> 627 CFR 112.7(h)(2) Failed to provide vehicular departure system for loading and unloading racks V ❑R ❑COS <br /> 628 CFR 112.7(h)(3) Failed to inspect lowermost drains and outlets prior to filling and departure of vehicles V ❑R ❑COS <br /> 629 CFR 112.7(i) Failed to evaluate field constructed container for brittle fracture and take appropriate action V ❑R in COS <br /> 630 CFR 112.7(k) Failure to provide general secondary containment or alternative for oil-filled operational equipment V o R o COS <br /> SPCC Plan Requirements for Onshore Facilities(excluding production facilities) <br /> 701 CFR 112.8(b)(1) Failure to ensure drainage from diked areas is restrained by valves or alternative method V o R u COS <br /> 702 CFR 112.8(b)(2) Failed to use manual open-and-closed design valves for the drainage of diked areas V ❑R o COS <br /> Page 2 of 6 <br />