My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10858
>
2300 - Underground Storage Tank Program
>
PR0526212
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/21/2020 9:26:53 AM
Creation date
9/4/2018 1:38:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0526212
PE
2351
FACILITY_ID
FA0017737
FACILITY_NAME
CHEVRON STATION #307709*
STREET_NUMBER
10858
STREET_NAME
TRINITY
STREET_TYPE
PKWY
City
STOCKTON
Zip
95219
APN
06602015
CURRENT_STATUS
01
SITE_LOCATION
10858 TRINITY PKWY
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
314
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />CHEVRON STATION #307709" <br />10858 TRINITY PKWY, STOCKTON <br />March 20, 2018 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />305 <br />HSC 25290.1(e) VPH monitoring of the interstitial spaces of the UST system is not maintained. <br />The S1 87 product STP sensor, S2 87 vent fill sensor and S4 91 product STP sensor failed to get a high liquid alarm <br />when tested. The technician on site cleaned out debris from the S1 and S2 sensor and replaced the high liquid float <br />for the S4 sensor "like for like." The interstitial space of the UST shall be maintained, as designed, under constant <br />vacuum such that a breach in the primary or secondary containment is detected before the hazardous substance is <br />released into the environment. The sensors were retested during the inspection. All passed. <br />This was corrected on site. <br />This is a repeat violation, Class II. <br />318 <br />CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br />The Diesel electronic plld line leak detector failed to detect a leak when tested. All line leak detectors shall be <br />capable of detecting a 3 -gallon per hour leak at 10 psi. The technician on site purged the product line and replaced <br />the jet siphon valve, retested the leak detector and declared it a pass. <br />This was corrected on site. <br />This is a repeat violation, Class II. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by April 30, 2018. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />In the future, if the spill containers fail the tightness test, the SJCEHD will require new spill containers that have <br />a five gallon capacity. <br />AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br />THIS FACILITY BACK INTO COMPLIANCE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Received by: Date: March 20, 2018 <br />Inspector: <br />Inspector Phone: <br />Printed Name and Title: <br />JOHN ALANIZ, EH Specialist <br />(209) 468-3147 <br />Georgina Williams, Cashier <br />EHD 23-01 Rev. 09/22/16 <br />Page 4 of 4 <br />FA0017737 PR0526212 SCO01 03/20/2018 <br />Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.