My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10858
>
2300 - Underground Storage Tank Program
>
PR0526212
>
COMPLIANCE INFO_2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2023 3:02:30 PM
Creation date
9/6/2018 10:43:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO_2009
FileName_PostFix
2009
RECORD_ID
PR0526212
PE
2351
FACILITY_ID
FA0017737
FACILITY_NAME
CHEVRON STATION #307709*
STREET_NUMBER
10858
STREET_NAME
TRINITY
STREET_TYPE
PKWY
City
STOCKTON
Zip
95219
APN
06602015
CURRENT_STATUS
01
SITE_LOCATION
10858 TRINITY PKWY
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
345
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page 2. <br />8. FILL RISER CONTAINMENT SUMP'.. LSTING <br />Facility is Not Equipped With Fill Riser Containment Sumps <br />Fill Riser Containment Sumps are Present, but were Not Tested <br />Test Method Developed By: <br />F-1 <br />Sump Manufacturer Industry Standard X� Professional Engineer <br />Other (Sped) <br />Test Method Used: <br />F] <br />Pressure Vacuum Hydrostatic <br />Other (Spec) <br />Test Equipment Used: vplt <br />Equipment Resolution: inches <br />Fill Sump # 1 UNL <br />4 8 1 <br />Fill Sump # <br />Fill Sump # <br />Fill Sump # <br />Sump Diameter: <br />Sump Depth: <br />841 <br />Height from Tank Top to Top of <br />Highest Piping Pentration: <br />2 911 <br />Height from Tank Top to <br />Lowest Electrical Pentration: <br />2311 <br />Condition of Sump prior to <br />testing: <br />good <br />Portion of Sump Tested: <br />2 511 <br />Sump Material: <br />f ibe rg 1 s <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />5min <br />Test Start Time: <br />13:13 <br />Initial Reading (Ri ): <br />0 <br />Test End Time: <br />13 :43 <br />Final Reading (RF ): <br />-.001211 <br />Test Duration: <br />3 Omin <br />Change in Reading (RF - RI ): <br />-.001211 <br />Pass/Fail Threshold or Criteria: <br />.00211 <br />Test Result: <br />[Z]Pass D Fail <br />Pass Fail <br />E Pass Fail <br />E] Pass Fail <br />Is there a sensor in the sump? <br />X <br />Yes <br />Ll <br />No <br />❑ Yes <br />No <br />Yes ❑ No <br />Yes <br />Ll <br />No <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />EYes ❑NoE]NA <br />E]Yes ONo❑N <br />Yes E:]NoE]NA <br />[]Yes [—]No[]N <br />Was sensor removed for testing? <br />MYes <br />IN2LNA <br />Yes ❑No❑N <br />Yes <br />N <br />NA <br />Yes <br />No[]N <br />Was sensor properly replaced and <br />verified functional after testing? <br />IflYes N NA <br />1:1 c[:] <br />Yes N <br />❑ [:]cN <br />❑ Yes ❑N NA <br />Yes N <br />[:]❑ <br />Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.