My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10858
>
2300 - Underground Storage Tank Program
>
PR0526212
>
COMPLIANCE INFO_2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2023 3:02:30 PM
Creation date
9/6/2018 10:43:17 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO_2009
FileName_PostFix
2009
RECORD_ID
PR0526212
PE
2351
FACILITY_ID
FA0017737
FACILITY_NAME
CHEVRON STATION #307709*
STREET_NUMBER
10858
STREET_NAME
TRINITY
STREET_TYPE
PKWY
City
STOCKTON
Zip
95219
APN
06602015
CURRENT_STATUS
01
SITE_LOCATION
10858 TRINITY PKWY
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
345
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ak <br />Awk <br />INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br />P, Tenlawo/ogy <br />8501 N MOPAC EXPRESSWAY, SUITE 400 <br />TEST DATE: 09/14/09 <br />AUSTIN, TEXAS 78759 (512) 451-6334 WORK ORDER NUMBER: 2269078 <br />CLIENT: CHEVRON PRODUCTS <br />SITE: CHEVRON 307709 <br />TANK INFORMATION <br />Tank ID: 3 <br />Tank manifolded: No Bottom to top fill in inches: <br />1.18.0 <br />Product: DIESEL <br />Vent manifolded: NO Bottom to grade in inches: <br />Capacity in gallons: 7,817 Vapor recovery manifolded: NO Fill pipe length in inches: <br />Diameter in inches: 118.00 <br />Overfill protection: YES Fill pipe diameter in inches: <br />Length in inches: 167 <br />Overspill protection: YES Stage I vapor recovery: <br />NONE <br />Material: DW FIBERG <br />Installed: ATG Stage II vapor recovery: <br />NONE <br />CP installed on: <br />COMMENTS <br />TANK TEST RESULTS Test Method: NONE <br />LEAK DETECTOR TEST RESULTS Test method: <br />PSI at tank bottom: <br />New/passed Failed/replaced New/passed <br />Failed/replaced <br />Fluid level in inches: <br />L.D. #1 L.D. #1 L.D. #2 <br />L.D. #2 <br />UFT/OFT: <br />Make: VAPORLESS <br />Fluid volume in gallons: <br />Model: LD2000 <br />Tank water level in inches: <br />S/N: 08121218 <br />Test time: NOT <br />Open time in sec: 6.00 <br />Number of thermisters: TESTED <br />Holding psi: 26 <br />NOT <br />Specific gravity: <br />Resiliency cc: 470 TESTED <br />Water table depth in inches: <br />Test leak rate ml/m: 189.0 <br />Determined by (method): <br />Metering psi: 20 <br />Leak rate in gph: <br />Calib. leak in gph: 3.00 <br />Result: <br />Results: PASS <br />COMMENTS <br />COMMENTS <br />ULLAGE TEST RESULTSTest Method: NONE <br />LINE TEST RESULTS Test type: TLD -1 <br />Test time: <br />Ullage volume: <br />Material: DW FIBERG <br />Ullage pressure: <br />Diameter (in): <br />Results: <br />Length (ft): <br />Test psi: <br />DATA FOR UTS-4T ONLY: <br />Bleedback cc: <br />Time of test 1: <br />Test time (min): <br />Temperature: NOT <br />Start time: NOT NOT NOT <br />NOT <br />Flow rate (cfh): TESTED <br />End time: TESTED TESTED TESTED <br />TESTED <br />Time of test 2: <br />Final gph: <br />Temperature: <br />Result: <br />Flow rate (cfh): <br />Pump type: PRESSURE <br />Time of test 3: <br />Pump make: FE PETRO <br />Temperature: <br />Flow rate (cfh): <br />Impact Valves Operational: YES <br />COMMENTS <br />COMMENTS <br />Printed 09/30/2009 08:28 ACRAMER <br />