My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006 - 2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRINITY
>
10858
>
2300 - Underground Storage Tank Program
>
PR0526212
>
COMPLIANCE INFO_2006 - 2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/7/2018 2:32:22 PM
Creation date
9/7/2018 2:01:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO_2006 - 2008
FileName_PostFix
2006 - 2008
RECORD_ID
PR0526212
PE
2351
FACILITY_ID
FA0017737
FACILITY_NAME
CHEVRON STATION #307709*
STREET_NUMBER
10858
STREET_NAME
TRINITY
STREET_TYPE
PKWY
City
STOCKTON
Zip
95219
APN
06602015
CURRENT_STATUS
01
SITE_LOCATION
10858 TRINITY PKWY
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
240
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
001906 <br />UNIFIED PROGRAM CONSOLIDATED FORM <br />UNDERGROUND STORAGE TANK <br />MONITORING PLAN — age 2 of 2) <br />VI. UNDER DISPENSER CONTAINMENT (UDQ MONITORING (Check all <br />that <br />apply <br />UD ONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) <br />1. CONTINUOUS ELECTRONIC MONITORING ❑ 2. FLOAT AND CHAIN ASSEMBLY ❑ 3. ELECTRONIC STAND-ALONE <br />490-54a <br />4. NO DISPENSERS <br />_........---.._....-----..-.__.._._.,_.._..__.._._____._____.__ ❑T�99.OTHER Specify) <br />490-54b. <br />LEAK MONITOR MANUFACTURER: V t { C�t.f 490-55. MODEL #: L 5' <br />49&56. <br />LEAK SENSOR MANUFACTURER: C QpGi 490-57• MODEL #(S): - ZO <br />490-5s. <br />DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. a.�YES El b. NO <br />490.59, <br />,�,�/ <br />UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ? YES ❑ b. NO <br />490-0- <br />FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. YES ❑ b. NO <br />UDC <br />49MI. <br />490-62• <br />MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER. YES ❑ b. NO <br />_ .... - . .. .... <br />UDC CONSTRUCTION IS. ❑ 1. SINGLE WALL 2. DOUBLE WALL <br />49"3 <br />IF DOUBLE WALL.490.64L <br />UDC INTERSTITIAL SPACE IS MONITORED BY: a. LIQUID ❑ b. PRESSURE [3 <br />,/VACUUM <br />A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS. F a. YES ❑ b. NO <br />490-64b. <br />VII. PERIODIC SYSTEM TESTING <br />❑ 1. ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED <br />490-6 _ <br />LEA MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED. 123 CCR §2644. <br />2. SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. <br />490-66. <br />® 3. SPILL BUCKETS ARE TESTED ANNUALLY. <br />490.67. <br />VIII. RECORD _KEEPING <br />The following monitoring/maintet nce records are kept for this facility: <br />490.68. <br />® a. ALARM LOGS (� b. VISUAL INSPECTION RECORDS ❑ c. TANK INTEGRITY TESTING RESULTS <br />❑SIR TESTING RESULTS (and supporting documentation records) [Ie. TANK GAUGING RESULTS (and supporting documentation records) <br />Q f. ATG TESTING RESULTS (and supporting documentation records) ❑ g. CORROSION PROTECTION 60 -DAY LOGS <br />h. EQUIPMENT MAINTENANCE AND CALIBRATION RECORDS <br />IX. TRAINING <br />® Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to theirjob duties: <br />490-69& <br />REFERENCE DOCUMENTS MAINTAINED AT FACILITY (Check all that apply) <br />® THIS UNDERGROUND STORAGE TANK MONITORING PLAN (Required) <br />490.69b. <br />® OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT (Required) <br />490.69& <br />❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br />490-69d. <br />❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW <br />490.69& <br />❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS MANUAL AND <br />490.69f. <br />STATISTICAL INVENTORY RECONCILIATION" <br />❑ SWRCB PUBLICATION: "UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS" <br />490698 <br />❑ OTHER (Specify): <br />490.69h. <br />This facility has a "Designated UST Operator" who has passed the California UST System Operator Exam administered by the International Code Council <br />490-69L <br />490-70. <br />(ICC). The "Designated UST Operator" will train facility employees in the proper operation and maintenance of the UST systems annually, and within 30 <br />days of hire. This training will include, but is not limited to, the following: <br />➢ Operation of the UST systems in a manner consistent with the facility's best management practices. <br />➢ The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan. <br />➢ The facility employee's role with regard to spills and overfills as specified in the facility's UST Response Plan. <br />➢ Name(s) of contact person(s) for emergencies and monitoring alarms. <br />X. COMMENTS/ADDITIONAL INFORMATION <br />Provide addici` 'i cumn:enis here or indicate how many pa .ei whir additional n:ormation on speci - mo. icor g pr ced reS are(a[(aehe0 LO Li17is Pian.71 <br />fti�� J( t)� <br />XI. PERSONNEL RESPONSIBILITIES <br />The UST Owner/Operator is responsible for ensuring that: 1.) the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered <br />by thisplan occurs; 2.1all conditions that indicate a possible release are investigated; and 3.) all monitoring records are maintained properly. <br />THE FOLLOWING PERSON(S) ARE R/E��SPONSI LE FOR THE MONITORING EQUIPMENT MAINTENANCE: <br />--iiPERFORMING <br />NAME:'jMM Mdtna SChne w� C?rovp �tA1G 490-72 -CD <br />90 n. TITLE: �01� � ha,ltr <br />490-73. <br />NAME: 490-74. TITLE: a <br />490-75. <br />The Designated UST Operator shall perform a monthly visual inspection of the facility, provide a report to the owner/operator, and inform the owner/operator of any <br />conditions that need follow-up action. <br />XII. OWNER/OPERATOR SIGNATURE <br />CERTIFICATION: I certif that the information provided herein is true and accurate to the best of my knowledge. <br />APPLICANT SIGNATURE _ _oe� <br />DATE: <br />490-77. <br />REPRESENTING: [11. lank Ownu/O rnror 2. Facili Owna/0 efator . Authorized R rwentative of Ownar 490-76. <br />490.78. <br />APPLICANT NAME (print): � � <br />APPLICANTITLE:� <br />490-79 <br />UPCF UST -D (12/2007) 3/4 <br />www.tinidocs.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.