My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
REMOVAL 2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
STOCKTON
>
239
>
2300 - Underground Storage Tank Program
>
PR0231482
>
REMOVAL 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2018 5:08:40 PM
Creation date
9/12/2018 5:00:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
REMOVAL 2009
FileName_PostFix
2009
RECORD_ID
PR0231482
PE
2361
FACILITY_ID
FA0000720
FACILITY_NAME
MADSENS SUNRISE DAIRY
STREET_NUMBER
239
Direction
S
STREET_NAME
STOCKTON
STREET_TYPE
ST
City
RIPON
Zip
95366
APN
25927805
CURRENT_STATUS
02
SITE_LOCATION
239 S STOCKTON ST
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAMPLING PROTOCOL FOR ROUTINE TANK REMOVALS <br />The following represents minimum sampling criterion required for closure compliance. Soil samples collected shall be representative <br />of native soils beneath the tank's invert (tank's bottom) at a collection depth not to exceed 2 - 4 feet. If contamination is documented <br />during closure, an Unauthorized Release Notification must be completed and submitted within five (5) working days pursuant to <br />California Health & Safety Code, Section 25295. <br />WATER NOT PRESENT IN THE TANK PIT <br />TANK <br /># <br />TANK SIZE <br />(Gallons) <br />MINIMUM NUMBER <br />of SOIL SAMPLES <br />LOCATION OF SOIL SAMPLES <br />PIPING SOIL SAMPLES <br />< 1,000 <br />1 per Tank <br />Fill OR Pump End of Tank <br />LOCATION of SOIL <br />1,000 - 10,000 <br />2 per Tank <br />1 at each End of Tank <br />X <br />> 10,000 <br />3 or More <br />per Tank <br />Ends and Middle OR generally <br />y <br />spaced along the length of the Tank <br />WATRR N PRFSFNT nv mora .r <br />.�awnrwc <br />MINIMUM NUMBER <br />of SOIL SAMPLES <br />K <br />PIPING SOIL SAMPLES <br />1 Sample every 20 lineal feet <br />TANK SIZE <br />MINIMUM NUMBER <br />LOCATION of SOIL <br />7C <br />TANK & PIPING STOCKPII.E SAMPLES <br />2 Samples every 50 cubic yards <br />WATRR N PRFSFNT nv mora .r <br />SLAB PRESENT IN THE TANK PIT <br />Soil samples shall be obtained beneath the slab within native soils. Penetration through the obstruction will be required in order to <br />collect the samples. (Physical removal of the obstruction will allow sampling according to the above conditions.) <br />TANK <br /># <br />TANK SIZE <br />(Gallons) <br />MINIMUM NUMBER <br />of SOIL SAMPLES <br />LOCATION of SOIL SAMPLES <br />TANK <br />TANK SIZE <br />MINIMUM NUMBER <br />LOCATION of SOIL <br />MINIMUM NUMBER <br /># <br />(Gallons) <br />of SOIL SAMPLES <br />SAMPLES <br />of WATER SAMPLES <br />Ends and Middle and generally spaced <br />along the length of the Tank <br />< 10,000 <br />2 from wall next to tank ends <br />Single Tank <br />3 <br />at soil/groundwater interface <br />1 <br />& I below tank <br />> 10,000 OR <br />4 from wall next to tank ends <br />Tank Cluster <br />5 or more <br />at soil/groundwater interface <br />I <br />& I below each tank <br />SLAB PRESENT IN THE TANK PIT <br />Soil samples shall be obtained beneath the slab within native soils. Penetration through the obstruction will be required in order to <br />collect the samples. (Physical removal of the obstruction will allow sampling according to the above conditions.) <br />TANK <br /># <br />TANK SIZE <br />(Gallons) <br />MINIMUM NUMBER <br />of SOIL SAMPLES <br />LOCATION of SOIL SAMPLES <br />< 1 000 <br />3 per Tank <br />Center and Ends OR Sides of Tank <br />1000-10000 <br />5 per Tank <br />Center and Ends OR Sides of Tank <br />> 10,000 <br />5 OR More per Tank <br />Ends and Middle and generally spaced <br />along the length of the Tank <br />EH 23 046 (Revised 07/31/09) <br />
The URL can be used to link to this page
Your browser does not support the video tag.