My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3702
>
2300 - Underground Storage Tank Program
>
PR0504432
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2021 1:43:02 PM
Creation date
9/17/2018 1:14:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0504432
PE
2361
FACILITY_ID
FA0006687
FACILITY_NAME
WALMART #1554
STREET_NUMBER
3702
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
13002010
CURRENT_STATUS
02
SITE_LOCATION
3702 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
fppOVR f C <br />STATE OF CALIFORNIA <br />STATE WATER RESOURCES CONTROL BOARD W tl�I e <br />UNDERGROUND STORAGE TANK PERMIT APPLICATION • FORM B ;� a <br />COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br />MARK ONLY ❑ I NEW PERMIT ❑ <br />3 RENEWAL PERMIT <br />❑ 5 CHANGE OF INFORMATION <br />❑ 7 PERMANENTLY CLOSED ON SITE <br />ONE ITEM ❑ 2 INTERIM PERMIT ❑ <br />4 AMENDED PERMIT <br />6 TEMPORARY TANK CLOSURE <br />❑ B TANK REMOVED <br />DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br />-370a <br />+ <br />I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br />A. OWNERS TANK I.D.%:R IB. MANUFACTURED BY: av • <br />C. DATE INSTALLED(MO/DAYNEAR) l D. TANK CAPACITY IN GALLONS: O <br />TANK CON IhNI, IFA -1 IS MARKEDCOMPUeFE ITEM C. <br />A ❑ 1 MOTOR VEHICLE FUEL 4 OIL <br />B. / <br />C. ❑ IaUNLEADED REGULAR❑ 3 DIESEL ❑ g AVIATIONGAS <br />❑ 4 GASAFIOL <br />❑ 2 PETROLEUM ❑ 80 EMPTY <br />i PRODUCT <br />❑:PREMIUM ❑ 7 METHANOL <br />UNLEADED ❑ 5 JET FUEL <br />❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN <br />❑ 2 WASTE <br />❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM 0. BELOW) <br />D. IF (A.1) IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED C. A. S. %: <br />111 TAMIZ T`TIMCTGIICTInM HAoVnNC L=UANIVINRDVP9 A R ANDC. AND ALL THAT APPLIES IN ROXD <br />IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND. BOTH IF APPLICABLE <br />A. <br />❑ I DOUBLE WALL <br />[V::]3 INGLE WALL WITH EXTERIOR LINER <br />❑ 95 UNKNOWN <br />A. TYPE OF <br />SYSTEM <br />❑ 2 SINGLE WALL <br />ECONDARY CONTAINMENT (VAULTED TANK) <br />❑ 99 OTHER <br />CONSTRUCTION <br />BARE STEEL <br />❑ 2 STAINLESS STEEL <br />❑ 3 FIBERGLASS <br />❑ 4 STEEL CLAD W/ FIBERGLASS REINFORCED PLASTIC <br />B. TANK <br />MATERIAL <br />❑ s CONCRETE <br />❑ 6 POLYVINYL CHLORIDE <br />❑ 7 ALUMINUM <br />❑ 8 100% METHANOL COMPATIBLE W/FRP <br />(PrimeryTmk) <br />❑ 9 BRONZE <br />❑ 70 GALVANIZED STEEL <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />❑ 1 RUBBER LINED <br />❑ 2 ALKYD LINING <br />❑ 3 EPDXY LINING <br />❑ 4 PHENOLIC LINING <br />C. INTERIOR <br />❑ 5 GLASS LINING <br />❑ 6 UNLINED <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />LINING <br />7 STEEL W/ COATING A B 100% METHANOL COM AT LE WIFRP <br />PROTECTION <br />A U <br />9 GALVANIZED STEEL <br />IS LINING MATERIA COMPATIBLE WITH 100% METHANOL? <br />YES_ NO— <br />A U 95 UNKNOWN 99 OTH vajamedgg <br />D. CORROSION <br />❑ I POLYETHYLENE WRAP <br />❑ 2 COATING <br />❑ 3 VINYL WRAP <br />❑ 4 FIBERGLASS REINFORCED PLASTIC <br />PROTECTION <br />❑ 5 CATHODIC PROTECTION ❑ 91 NONE <br />❑ 95 UNKNOWN <br />❑ 99 OTHER <br />IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND. BOTH IF APPLICABLE <br />A. <br />SYSTEM TYPE <br />A_U <br />1 SUCTION <br />02 <br />PRESSURE A U <br />3 GRAVITY A U 9B OTHER <br />B. <br />CONSTRUCTION <br />A& <br />SINGLE WALL <br />A U <br />2 DOUBLE WALL A U <br />3 LINED TRENCH A U 96 UNKNOWN A U 99 OTHER <br />A U <br />I BARESTEEL <br />A U <br />2 STAINLESS STEEL A U <br />3 POLYVINYL CHLORIDE (PVC) A U 4 FIBERGLASS PIPE <br />C. <br />MATERIAL AND <br />CORROSION <br />A U <br />5 ALUMINUM <br />A U <br />6 CONCRETE A U <br />7 STEEL W/ COATING A B 100% METHANOL COM AT LE WIFRP <br />PROTECTION <br />A U <br />9 GALVANIZED STEEL <br />A U <br />10 CATHODIC PROTECTION <br />A U 95 UNKNOWN 99 OTH vajamedgg <br />D. <br />LEAK DETECTION <br />❑ I <br />AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ 3 INTERSTITIALOTHER <br />TANK VAK DETECTION <br />1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VAPOR MONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 6 GROUND WATER MONITORING <br />❑ 6 TANK TESTING ❑ 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br />VI. TANK CLOSURE INFORMATION <br />L ES]IMAVD DATE LAST USED(MO/0AY/YR) 2. ESTIMATED I REMAININGQUANTTY GALLONS 3 WAS <br />INERTMATERIALWITH <br />? YES ❑ NO E7 <br />THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY, AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br />LOCAL AGENCY USE ONLY <br />THE STATE I.D. NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br />COUNTY# JURISDICTION# FA TANKS <br />STATE I.D.# <br />m -3 <br />PERMIT NUMBER <br />I PERMIT APPROVED BYIDATE <br />PERMIT EXPIRATION DATE <br />FORM B (9-90) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION • FORMA, UNLESS A CURRENT FORMA HAS BEEN FILED. <br />ElIIT/ <br />` S..0i <br />FOR9971SM <br />
The URL can be used to link to this page
Your browser does not support the video tag.