My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007 - 2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ARMY
>
1624
>
2300 - Underground Storage Tank Program
>
PR0231014
>
COMPLIANCE INFO_2007 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2019 2:52:26 PM
Creation date
9/20/2018 9:29:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2017
RECORD_ID
PR0231014
PE
2361
FACILITY_ID
FA0003777
FACILITY_NAME
TOYS R US
STREET_NUMBER
1624
STREET_NAME
ARMY
STREET_TYPE
CT
City
STOCKTON
Zip
95206
APN
16334002
CURRENT_STATUS
01
SITE_LOCATION
1624 ARMY CT
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
345
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.smgov.or /q ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />FacilityInspection <br />Name: Toys s R Us Facility Address: 1624 Army Court, Stockton Date: Oct 2, 2012 <br />VIOLATIONS <br /># <br />I C1 <br />I C2 <br />M <br />I Code Section <br />HSC = CA Health and Safety Code; CFR = Code of Federal ReguWions <br />C1 = Class 1 violation: C2 = Class 2 vitiation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />Other VioiaHons <br />999 1 10ther: See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR -Notice to Comply) <br />UST Inspection: Routine & Annual Monitoring System Certification. Class II/ Repeat Violation: 104, 206 <br />104. Financial responsibility documents have not been submitted to the EHD for 2012 year. No documents <br />received for 2011 year either. Current financial responsibility documents are required to be submitted annually. <br />Complete and submit a copy of the Certification of Financial Responsibility along with the insurance policy or a <br />Letter from Chief Financial Officer. <br />206. The Designated Operator (DO) employee training for all employees responsible for the diesel tank were not <br />current. Last training by the designated operator occurred on September 29, 2011. No current records can be <br />located. The DO shall train facility employees for which he or she is responsible in the proper operation and <br />maintenance of the UST system once every 12 months. The training shall include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices <br />2. Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br />3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br />4. Name of the contact person(s) for emergencies and monitoring equipment alarms <br />Ensure that employees have been trained by the DO, maintain the list on site, and submit a copy of the training <br />records to the EHD. <br />Submit to SJC EHD within 30 days (11/02/12): <br />1. one copy of the completed "Return to Compliance Certification" form <br />2. a written corrective action statement how each of the above violations would be corrected along with how to <br />ensure violation would not be repeated <br />3. requested / supporting documentation ie. financial responsibility & employee training roster <br />Notes: - On site with Facility Mgr explained UST system (set up & sensors), testing requirements & dates, <br />documentation (DO monthly reports & alarm records & maintenance/ repairs), employee training. <br />Explained Hazardous waste: storage period time, labeling, types of waste generated, training records, disposal <br />records, emergency action plan/ contingency plan, free training <br />Explained Universal waste: storage period time, labeling, types of waste generated <br />-Next secondary containment testing due by 09/2013. Submit 48 hr advance notification of test <br />-Last MC,S13 testing performed 09/16/11. Was due by 09/2012 but reschedule b/c Inspector unavailable <br />-Provided free training schedule. Sign up for Hazardous & Universal waste. Underground Storage Tanks. <br />-Facility outsourced vehicle maintenance to 3rd party contractors. Closed shop 03/2012. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Inspector. <br />Received By„/ <br />Title: <br />=HD 23-02 Rev 04/19/1 <br />Page 3 <br />UST INSPECTION REPOR <br />
The URL can be used to link to this page
Your browser does not support the video tag.