FA0003777
FACILITY_NAME
TOYS R US
STREET_NUMBER
1624
STREET_NAME
ARMY
STREET_TYPE
CT
City
STOCKTON
Zip
95206
APN
16334002
CURRENT_STATUS
01
SITE_LOCATION
1624 ARMY CT
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
289
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Positive Seal Quality Materials <br />Sump Entry <br />Flexible entry boots have been <br />tested to withstand a minimum <br />of 6' of liquid head pressure. <br />These seals provide a studded <br />flange connection to create a <br />positive and secure seal where <br />the rubber contacts the sump <br />wall and also around the pipe <br />or conduit. Tightening down <br />on a series of stud fasteners <br />with a compression ring pro- <br />vides a high compression <br />mechanical seal compared to <br />screw on type bulkhead seals. <br />Angled Entries <br />Pipe and conduit entering <br />the containment sumps may not <br />be perpendicular with the sump <br />wall. Angled entries are generally <br />a result of directional plumbing <br />restrictions on the inside of the <br />containment chamber due to <br />space limitations. Flexible entry <br />boots are flexible enough to per- <br />mit angled pipe or conduit entries <br />(on two axises) into the sidewall <br />of a containment chamber. All <br />flexible entry boots permit angled <br />entries up to a 15 degree angle <br />off the perpendicular center line <br />in any direction without leaking or <br />putting undue stress on the pipe <br />or conduit seal. <br />Universal Alignment <br />These seals are also capable <br />of universal pipe alignment <br />either up and down or side to <br />side. This feature allows accom- <br />modation of pipe entry holes <br />which are installed slightly off <br />exact center alignment in the <br />chamber wall. This movement <br />will prevent the chamber wall <br />from putting undue stress on the <br />pipe coupling/fitting joint and the <br />entry boot as well. For flexible <br />piping applications within dis- <br />penser sumps, the stresses on <br />the pipe fittings below the prod- <br />uct inlets are minimized by the <br />boot's flexibility. <br />Corrosion Resistance <br />The exterior studded metal <br />compression ring that provides <br />the positive sealing pressure is <br />encapsulated within rubber to <br />protect it from corrosion. More <br />than a 1/8" of rubber isolates the <br />metallic studded ring from the <br />ground environment. All studs <br />are made of 401 stainless steel <br />and are only exposed on the <br />inside of the containment sump. <br />Chemical Compatibility <br />All seals are made of specially <br />formulated Buna-N rubber <br />compound which has been <br />independently tested to insure <br />its compatibility with a wide <br />assortment of chemicals. <br />These tests include measuring <br />the material's retention of <br />properties as well as the <br />physical characteristics of <br />the seal after exposure. <br />UL Listed <br />Environ flexible entry boots are Listed with Underwriters <br />Laboratories, Inc., (UL). The scope of the tests include broad <br />compatibility testing for both petroleum products and burial <br />environments as well as physical testing to confirm the entry <br />boots structural integrity and liquid tightness. <br />Sizes Available <br />Application1.32" 4.25" FEB -3157 Designed to seal 1/2 3/4 or 1" rigid conduit. <br />1.81" 4.25" FEB -3150 <br />1.81" <br />4.75" <br />FEB -5150 <br />1.81" <br />6.25" <br />FEB -6150 <br />2.37" <br />6.25" <br />FEB -6200 <br />3.50" 6.25" FEB -6300 <br />3.6" 7.75" FEB -7360 <br />4.50" 7.75" FEB -7400 <br />Designed to seal 1-1/2" standard rigid pipe. <br />Designed to seal 1-1/2" GeoFlexflexible pipe. <br />Designed to seal 1-1/2" GeoFlexflexible pipe. <br />Designed to seal 2" GeoR"flexible pipe. <br />Designed to seal 3" standard rigid pipe. <br />Designed to seal 3" Geoflexflexible pipe. <br />Designed to seal 4" standard rigid pipe. <br />4.50" <br />7.75" <br />GDB-7450 <br />Designed to seal 4" GeoDuct flexible ducting. <br />6.50" <br />9" <br />FEB -8600 <br />Designed to seal 6" standard rigid pipe. <br />1.81" <br />7.75" <br />GDB-4515 <br />Seals 4" GeoDuct to 1-1/2" GeoFlex <br />2.37" 7.75" GDB-4520 <br />3.5" 7.75" GDB-4530 <br />6 Environ Literature Can Be Accessed From Our Websti:'' <br />www.envproduct com <br />Seals 4" GeoDuct to 2" GeoFlex <br />Seals 4" GeoDuct to 1-1/2"GeoFlex w/coax (Donut) <br />Publication: EPF-0090 P.O. Box 330 • Smithfield, NC 27577-0330 • Tel: (919) 359-3400 • Customer Service (800) 833-1883 • Fax: (919) 359-3687 <br />Issue Date: 05-02-02 <br />Supersedes:11-06-01 U.S. Patent 5263794, 5271518, 5297896, 5366318, 5346625, 5398976, Other U.S. and Worldwide Patents Pending • ® Copyright 2002 <br />
The URL can be used to link to this page
Your browser does not support the video tag.