Laserfiche WebLink
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sicehd.com <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility V/I LG t y p/%GL,-,L e <br />Name: <br />FacilityInspection <br />Address: / r .Z4 FA"'u'utl <br />Date: 3 F,-'/ --f <br />Received <br />By (initial): <br />EHD 23-01 REV 07/28/16 <br />Page 2 <br />I nspector <br />Initial: <br />UST INSPECTION REPORT <br />On Site Records <br />V R COS <br />208 <br />CCR 2650(e) <br />Failed to notify the EHD of a reportable unauthorized release (V854) <br />❑ ❑ ❑ <br />209 <br />CCR 2715(c) <br />Designated operator did not inspect all required items and/or the inspection reports not completed (V723) <br />❑ ❑ <br />210 <br />CCR 2715(e) <br />Designated operator monthly inspection reports not maintained on site for at least 12 months (V722) <br />❑ ❑ ❑ <br />211 <br />CCR 2715(f) <br />Designated operator employee training not performed or log not kept (V727) <br />❑ ❑ <br />212 <br />CCR 2715(f)(2) <br />Unstaffed facility failed to have or implement a training program approved by the EHD (V740) <br />❑ ❑ ❑ <br />213 <br />HSC 25281.5(b)(2) <br />Unburied fuel piping at marinas not visually inspected at least daily or log not kept (V729) <br />❑ ❑ ❑ <br />214 <br />HSC 25281.5(b)(3) <br />Unburied emergency generator fuel piping not visually inspected at least monthly or log kept (V728) <br />❑ ❑ ❑ <br />Received <br />By (initial): <br />EHD 23-01 REV 07/28/16 <br />Page 2 <br />I nspector <br />Initial: <br />UST INSPECTION REPORT <br />UST System Observations <br />V R COS <br />301 <br />HSC 25292.1 <br />UST system is not operated to prevent unauthorized release, including spills and overfills (V715) <br />❑ ❑ ❑ <br />302 <br />HSC 25291(b) <br />UST system incapable of detecting leak from primary into secondary containment (pre -Jul 2003) (V688) <br />❑ ❑ ❑ <br />303 <br />HSC 25290.2(d) <br />Monitoring system not maintained to detect entry into secondary containment (Jul 2003 -Jun 2004) (V693) <br />❑ ❑ ❑ <br />304 <br />HSC 25290.1(d) <br />Monitoring system not maintained to detect entry into secondary containment (after Jul 2004) (V695) <br />❑ ❑ ❑ <br />305 <br />HSC 25290.1(e) <br />VPH monitoring of the interstitial spaces of the UST system is not maintained (V694) <br />❑ ❑ ❑ <br />306 <br />CCR 2630(d) <br />Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity (V691) <br />❑ ❑ ❑ <br />307 <br />CCR 2632(c) <br />Monitoring system of the interstitial space of a double walled system not maintained (V679) <br />❑ ❑ ❑ <br />308 <br />CCR 2636(f) <br />Failed to maintain a continuous monitoring system that activates an audible and visual alarm (V678) <br />❑ ❑ 1 ❑ <br />309 <br />CCR 2636(f)(1) <br />Monitoring in sump/UDC failed to activate an audible and visual alarm or stop the flow of product (V684) <br />❑ ❑ ❑ <br />310 <br />CCR 2636(f)(5) <br />Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs (V683) <br />❑ ❑ ❑ <br />311 <br />CCR 2638(a), <br />2641 0) <br />Failed to properly program or operate leak detection equipment (V677) <br />❑ ❑ ❑ <br />312 <br />CCR 2638(f) <br />Failed to affix a tag sticker on monitoring equipment certified, repaired, or replaced (V681) <br />❑ ❑ ❑ <br />313 <br />HSC 25290.1, <br />25290.2, 29291 <br />Failure to construct, operate, and maintain primary containment as product -tight (V847) <br />❑ ❑ ❑ <br />314 <br />HSC 25290.1, <br />25290.2, 29291 <br />Failure to have secondary containment or secondary containment not tight (V710) <br />❑ ❑ ❑ <br />315 <br />HSC 25291(e) <br />Water in secondary containment not removed, analyzed, and properly disposed of (pre -Jul 2003) (V849) <br />❑ ❑ ❑ <br />316 <br />HSC 25290.1(c)(3), <br />25290.2 (c)(3) <br />Secondary containment not constructed to prevent water intrusion (after Jul 2003) (V707) <br />❑ ❑ ❑ <br />317 <br />CCR 2636(%2) <br />Line leak detector not installed (V700) <br />❑ ❑ ❑ <br />318 <br />CCR 2636(f)(2) <br />Leak detector failed to detect a 3.0 gph leak at 10 psi (V704) <br />❑ ❑ ❑ <br />319 <br />CCR 2635(b) <br />No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty (V712) <br />❑ ❑ <br />320 <br />CCR 2635(b)(2) <br />Overfill prevention system not present or failed to meet overfill requirements (V716) <br />❑ ❑ ❑ <br />321 <br />CCR 2635(b)(2) <br />Overfill prevention system was overridden (V845) <br />❑ ❑ ❑ <br />322 <br />HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status (V739) <br />❑ ❑ ❑ <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST failed to meet exemption status (V855) <br />❑ ❑ ❑ <br />324 <br />CCR 2717.1(8) <br />Tampered with red tag (V742) <br />❑ 1 ❑ ❑ <br />325 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST (V746) <br />❑ ❑ ❑ <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms (V692) <br />❑ ❑ ❑ <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored (V751) <br />❑ ❑ ❑ <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements (V747) <br />❑ ❑ ❑ <br />329 <br />HSC 25298 <br />Failed to comply with permanent closure requirements (V748) <br />❑ ❑ ❑ <br />330 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system (V846) <br />❑ ❑ ❑ <br />Received <br />By (initial): <br />EHD 23-01 REV 07/28/16 <br />Page 2 <br />I nspector <br />Initial: <br />UST INSPECTION REPORT <br />