SWRCB, January 2002 Page 3 of 3 <br />5. UNDER -DISPENSER CONTAINMENT (UDC) TESTING <br />Test Method Developed By: = UDC Manufacturer x Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum x Hydrostatic <br />❑ Other (Specie) <br />Test Equipment Used: Incon TS -STS <br />UDC #1 Sat. UDC # 2/3 Sat <br />iw <br />Equipment Resolution:.001" <br />UDC # <br />UDC # <br />UDC Manufacturer: <br />Bravo <br />Bravo <br />UDC Material: <br />FRP <br />FRP <br />UDC Depth: <br />30" <br />30" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />12" <br />12" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />10" <br />10" <br />Condition of UDC prior to <br />testing: <br />Clean <br />Clean <br />Portion of UDC Tested' <br />1/2 <br />1/2 <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?' <br />X Yes ❑ No ❑ <br />NA <br />X Yes ❑ No ❑ <br />NA <br />❑Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ <br />NA <br />Turbine shutdown response time <br />3 sec <br />3 Sec. <br />Is system programmed for fail- <br />safe shutdown?' <br />X Yes ❑ No ❑ <br />NA <br />X Yes ❑ No ❑ <br />NA <br />❑ Yes ❑ No ❑ <br />NA <br />❑ Yes ❑ No ❑ <br />NA <br />Was fail-safe verified to be <br />operational? <br />X Yes ❑ No ❑ <br />NA <br />X Yes ❑ No ❑ <br />NA <br />[]Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ <br />NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />15 min. <br />15 Min. <br />Test Start Time: <br />1:52 <br />1:52 <br />Initial Reading (Ri): <br />2.811 <br />1.634 <br />Test End Time: <br />2:07 <br />2:07 <br />Final Reading (RF): <br />2.811 <br />1.633 <br />Test Duration: <br />15 Min <br />15 Min. <br />Change in Reading (RF-Ri): <br />0 <br />0.001 <br />Pass/ Fail Threshold or Criteria: <br />0.002 <br />0.002 <br />Test Result: <br />X Pass ❑ Fail <br />X Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />X Yes ❑ No ❑ <br />NA <br />X Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />X Yes ❑ No ❑ <br />NA <br />X Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />