My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRESNO
>
1524
>
2300 - Underground Storage Tank Program
>
PR0506545
>
COMPLIANCE INFO_2015 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2023 10:44:17 AM
Creation date
9/24/2018 10:40:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2018
RECORD_ID
PR0506545
PE
2361
FACILITY_ID
FA0007491
FACILITY_NAME
VALLEY PACIFIC FRESNO AVE CARDLOCK
STREET_NUMBER
1524
STREET_NAME
FRESNO
STREET_TYPE
AVE
City
STOCKTON
Zip
95206
APN
16337025
CURRENT_STATUS
01
SITE_LOCATION
1524 FRESNO AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
311
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 <br />8. PIPING RUMP TFCTiN(_ <br />Page 4, of <br />Test Method Developed By: Sump Manufacturer `vx Industry Standard n Professional Engineer <br />Other (Specie) <br />Test Method Used: Pressure Vacuum x Hydrostatic <br />Other (Speck) <br />Test Equipment Used:Incon is-sts <br />Sump #Diesel Sump <br />Equipment Resolution:.00I" <br />Sump <br />Sump <br />Sump Diameter: <br />48" <br />Sump Depth: <br />55" <br />Sump Material: <br />FRP <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />38 <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />18" <br />Condition of sump prior to testing: <br />good <br />Portion of Sump Tested' <br />1/2 <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?* <br />X Yes -_ No <br />NA - <br />L Yes -; No - NA <br />J Yes No 7 -NA <br />11 Yes ❑ No ❑ NA <br />Turbine shutdown response time <br />3 sec <br />Is system programmed for fail-safe <br />shutdown?* <br />X Yes �, No <br />NA <br />Yes - No =: NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No E NA <br />Was fail-safe verified to be <br />operational?* <br />X Yes ^ No <br />NA <br />Yes No = NA <br />Yes 71No NA <br />❑Yes No NA <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />15 min. <br />Test Start Time: <br />11:39 <br />Initial Reading (Rj): <br />5.378 <br />Test End Time: <br />11:24 <br />Final Reading (RF): <br />5.378 <br />Test Duration: <br />15 min <br />Change in Reading (RF -111): <br />0 <br />Pass/Fail Threshold or Criteria: <br />0.002 <br />Test Result: <br />X Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Was sensor removed for testing? <br />X Yes N❑l No El- <br />Yes No NA <br />❑ Yes ❑ No [INA <br />❑ Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />X Yes E No ❑ <br />NA <br />11 Yes - No NA <br />❑Yes ❑ No -_ NA <br />❑Yes El No U NA <br />Comments - (itTclude information on repairs made prior to testing and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to as of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.