My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Z
>
ZUCKERMAN
>
1181
>
2800 - Aboveground Petroleum Storage Program
>
PR0530292
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2019 10:32:41 AM
Creation date
9/24/2018 3:47:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0530292
PE
2833
FACILITY_ID
FA0007096
FACILITY_NAME
PG&E: McDonald Island Compressor Station
STREET_NUMBER
1181
Direction
N
STREET_NAME
ZUCKERMAN
STREET_TYPE
Rd
City
Stockton
Zip
95206
APN
129-310-12
CURRENT_STATUS
01
SITE_LOCATION
1181 N Zuckerman Rd
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
71
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PG&E: McDonald Island Compressor Station 1181 N Zuckerman Rd, Stockton October 24, 2018 <br /> Other Violations <br /> 4050 See below Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 718 CFR 112.8(c)(11) Failed to locate properly or provide sufficient secondary containment for mobile/portable <br /> containers. <br /> The water pump with an 85 gallon diesel tank was observed with insufficient secondary containment. The <br /> secondary containment portable berm was collapsed at one corner. This would not allow for containment of 100 <br /> percent of the the capacity of the tank plus sufficient freeboard to contain precipitation.A 100 gallon diesel <br /> generator by the guard shack at the Turner Facility is described in the Plan as having general secondary <br /> containment and described in the plan as oil filled operational equipment. Per US EPA guidance the diesel tank on <br /> the generator qualifies as a bulk storage tank and must have sized secondary containment. Portable oil storage <br /> containers must be positioned or located to prevent a discharge and shall be furnished with a secondary means of <br /> containment sufficient to contain the capacity of the largest single container with sufficient freeboard to contain <br /> precipitation. Immediately provide sufficient secondary containment for this and all other portable containers at this <br /> facility, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork by November 23, 2018. <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209)468-3420. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: October 24, 2018 Inspector: Inspector Phone: <br /> Printed Name and Title: CESAR RUVALCABA, REHS (209)953-6213 <br /> ialph Roberts, Environmental Specialist <br /> FA0007096 PR0530292 SCO01 10/24/2018 <br /> EHD 28-01 Rev.09/27/2018 Page 4 of 4 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.