My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
O
>
120 (STATE ROUTE 120)
>
11011
>
2800 - Aboveground Petroleum Storage Program
>
PR0515723
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 4:00:57 PM
Creation date
9/25/2018 9:21:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0515723
PE
2831
FACILITY_ID
FA0004283
FACILITY_NAME
SOUTH SAN JOAQUIN IRR DIST
STREET_NUMBER
11011
Direction
E
STREET_NAME
STATE ROUTE 120
City
MANTECA
Zip
95336
APN
20820022
CURRENT_STATUS
01
SITE_LOCATION
11011 E HWY 120
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />ABOVEGROUND PETROLEUM STORAGE ACT (APSA) PROGRAM INSPECTION REPORT <br />CONTINUED <br />Facility SSJID <br />Facility 11011 H 120, Manteca <br />Inspection Sep 2, 2010 <br />Name: <br />Address: <br />Date: <br />VIOLATIONS <br /># <br />V <br />R <br />Code Section <br />HSC = CA Health and SafetyCode, CFR = Code of Federal Regulations; V = Violation; RV = Re violation <br />Specific requirements of HSC 25270.4.5(a) are identified as CFR code sections beginning with 112 <br />v <br />Failed to: test each aboveground container for integrity on a regular schedule or when repairs were made; <br />48 <br />CFR 112.8(c)(6) <br />inspect containers and container supports; or keep records of inspections and tests, or provide <br />equivalence as allowed by CFR 11 2.7(a) 2 <br />49 <br />CFR 112.8(c)(7) <br />Failed to provide effective leakage control through defective internal heating coils, or provide equivalence <br />as allowed by CFR 112.7(a)(2) <br />50 <br />CFR 112.8(c)(8) <br />Failed to install and regularly test approved liquid level sensing devices, or provide equivalence as allowed <br />by CFR 112-7(a)(2) <br />51 <br />CFR 112.8(c)(9) <br />Failed to observe effluent treatment facility frequently enough to detect system upsets that could cause a <br />discharge, or provide equivalence as allowed by CFR 11 2.7 a 2 <br />52 <br />CFR 112.8(c)(10) <br />Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas, or provide <br />equivalence as allowed by CFR 11 2.7 a 2 <br />53 <br />CFR 112.8(c)(11) <br />Failed to locate portable containers to prevent discharge or provide sufficient secondary containment <br />ca ac that will hold the volume of the largest container plus sufficient freeboard to contain preapitation <br />Failed to provide buried piping with a protective wrapping and coating and cathodic protection and/or <br />54 <br />CFR 112.8(d)(1) <br />inspect buried piping for corrosion damage when exposed, or provide equivalence as allowed by CFR <br />11 2.7 a 2 <br />55 <br />CFR 112.8(d)(2) <br />Failed to cap or blank -flange terminal connection at transfer point and mark its origin when piping is not in <br />service or in standby service for an extended time, or provide equivalence as allowed by CFR 11 2.7 a 2 <br />56 <br />CFR 112.8(d)(3) <br />Failed to design pipe supports to minimize abrasion and corrosion and to allow for expansion and <br />contraction, or Drovide equivalence as allowed by CFR 11 2.7 a 2 <br />57 <br />CFR 112.8(d)(4) <br />Failed to regularly inspect aboveground valves, piping, and appurtenances, or provide equivalence as <br />allowed b CFR 112.7(a)(2) <br />58 <br />CFR 112.8(d)(4) <br />Failed to conduct integrity and leak test for buried piping at time of installation, modification, construction, <br />relocation, or replacement, or provide equivalence as allowed by CFR 112.7(a)(2) <br />59 <br />CFR 112.8(d)(5) <br />Failed to provide adequate warnings to vehicles entering facility to protect aboveground piping and other <br />oil transfer o erations, or provide equivalence as allowed by CFR 112.7(a)(2) <br />999 <br />Other: <br />See attached "Continuation - Official Inspection Report" for violation(s) not listed above. <br />APSA Program Inspection Report <br />2 Facility failed to provide periodic inspection records. Immediately, located and submit copy of periodic <br />inspection report. If inspections are not performed and recorded as stated in the self certified SPCC plan <br />begin following the plan immediately. <br />Notes <br />A return to compliance certification must be submitted to this office with the requested documents within <br />30 days of receiving this report. <br />Provided free SPCC class information. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY <br />RATE. THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />nspector Phone. RecevedJy. y Title- <br />EHD 28-02 Rev 2/19/10 Page 3 APSA INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.