My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JAHANT
>
17300
>
2800 - Aboveground Petroleum Storage Program
>
PR0522199
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 2:16:01 PM
Creation date
9/25/2018 9:54:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0522199
PE
2832
FACILITY_ID
FA0010336
FACILITY_NAME
GEORGE REED INC
STREET_NUMBER
17300
STREET_NAME
JAHANT
STREET_TYPE
Rd
City
CLEMENTS
Zip
95227
APN
02113011
CURRENT_STATUS
01
SITE_LOCATION
17300 Jahant Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
EJimenez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN 10AQUIN <br />r %i--`CQUNTY- <br />!�!�, Crtntntec grttw< here <br />Environmental Health Department <br />Aboveground Petroleum Storage Act Inspection Report <br />Facility Name: <br />GEORGE REED INC <br />Facility Phone: <br />(209) 759-3331 Ext.0 <br />Date: <br />March 14, 2018 <br />Facility Address: <br />17300 Jahant Rd, CLEMENTS, CA 95227 <br />CERS ID: <br />10183457 <br />Inspection Contact: <br />Cory Turney <br />Title: <br />Plant Engineer <br />Phone: <br />(209) 531-6414 <br />Inspection Type: <br />ROUTINE INSPECTION - Operating Permit <br />Program: <br />12832-ASTFAC 10 K- </=100 K GAL CUMULATIVE <br />Consent For: Consent Given By: <br />❑x Ins ection ❑x Photos ❑ Sam les I Cory Turney, Plant Engineer <br />CCR = California Code of Regulations HSC = Health and Safety Code CFR = Code of Federal Regulations <br />V = Violation R = Repeat violation COS = Corrected on site during inspection <br />Aboveground Petroleum Storage Act <br />101 <br />HSC 25270.6(b) <br />Failed to pay APSA program annual fees <br />o V o R o COS <br />102 <br />HSC 25270.4.5(a) <br />Failed to prepare a written SPCC Plan in accordance with CFR Part 112 <br />o V o R o COS <br />103 <br />HSC 25270.6(a) <br />Failed to file HMBP or annual facility tank statement <br />o V o R o COS <br />104 <br />HSC 25270.8 <br />Failed to report spills or releases of 42 gallons (one barrel) or more <br />o V o R o COS <br />105 <br />CFR 112.1(b)(3),112.2 <br />Failure to property close tanks when making a claim of permanently closed <br />o V o R o COS <br />106 <br />CCR 25185(c)(3) <br />Failed to submit a written response within 30 days of receiving an inspection report <br />o V o R o COS <br />107 <br />HSC 25270.2(a)(4) <br />Failure to prepare SPCC plan when facility no longer meets oil -filled electrical equipment exclusion <br />in V o R o COS <br />108 <br />HSC 25270.4.5(a) <br />Failure of conditionally exempt facility to conduct inspections or install secondary containment <br />o V ❑ R o COS <br />Requirement to Prepare and Implement a SPCC Plan <br />201 <br />CFR 112.3(d) <br />Failure to have a licensed PE properly review and certify the SPCC plan <br />o V ❑ R COS <br />202 <br />CFR 112.3(e)(1) <br />Failed to maintain a copy of the Plan on site <br />o V o R o COS <br />203 <br />CFR 112.3 <br />Failure to implement the SPCC Plan <br />o V o R o COS <br />204 <br />CFR 112.3(g) <br />Failure to prepare SPCC Plan when facility no longer meets Qualified Facility criteria <br />❑ V ❑ R o COS <br />205 <br />CFR 112.3, 112.6 <br />Failure to prepare SPCC Plan that meets all applicable requirements <br />o V D R in COS <br />206 <br />CFR 112.3(d)(1) <br />Failure of owner to assure that the PE makes all required attestations in the Plan <br />❑ V ❑ R n COS <br />Amendment of SPCC Plan by Owners or Operators <br />301 <br />CFR 112.5(a) <br />Failed to amend Plan as necessary <br />■ V o R ❑ COS <br />302 <br />CFR 112.5(b) <br />Failed to review Plan once every five years and/or implement any resulting amendments <br />o V ❑ R o COS <br />303 <br />CFR 112.5(c) <br />Failed to have a PE certify technical amendments <br />o V o R o COS <br />304 <br />CFR 112.5(a), 112.5(b) <br />Failure to implement SPCC plan amendments within 6 months <br />o V ❑ R ❑ COS <br />Qualified Facility - Tier 1 <br />401 <br />CFR 112.6(a), 112.6(b) <br />Tier I Qualified Facility Plan not certified by the owner or a PE <br />u V ❑ R ❑ COS <br />402 <br />CFR 112.6(a)(2) <br />Owner of Tier I Qualified Facility failed to self certify technical amendment <br />❑ V o R in COS <br />403 <br />CFR 112.6(a)(3)(i) <br />Plan failed to predict direction/rate of flow/total quantity of oil potentially discharged <br />o V o R o COS <br />404 <br />CFR 112.6(a)(3)(ii) <br />No 2CT for bulk containers, or mobile storage containers not located to prevent discharge <br />o V o R o COS <br />405 <br />CFR 112.6(a)(3)(iii) <br />Overfill prevention for containers not provided, not described in Plan. or tested <br />❑ V ❑ R ❑ COS <br />Qualified Facility - Tier II <br />501 CFR 112.6(.)(1), Tier II Qualified Facility Plan not certified by the owner or a PE, as required o V o R o COS <br />112.6(b) <br />FA0010336 PR0522199 SCO01 03/14/2018 <br />EHD 28-01 Rev. 11/07/2017 Page 1 of 6 Aboveground Petroleum Storage Act OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />9171 9690 0935 0159 9052 84 <br />
The URL can be used to link to this page
Your browser does not support the video tag.