My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998 -2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRESNO
>
1524
>
2300 - Underground Storage Tank Program
>
PR0506545
>
COMPLIANCE INFO_1998 -2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/9/2023 9:38:21 AM
Creation date
9/28/2018 11:22:29 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO_1998 -2011
FileName_PostFix
1998 -2011
RECORD_ID
PR0506545
PE
2361
FACILITY_ID
FA0007491
FACILITY_NAME
VALLEY PACIFIC FRESNO AVE CARDLOCK
STREET_NUMBER
1524
STREET_NAME
FRESNO
STREET_TYPE
AVE
City
STOCKTON
Zip
95206
APN
16337025
CURRENT_STATUS
01
SITE_LOCATION
1524 FRESNO AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
269
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R . . <br />SWRCB, January 2002 <br />Page of� <br />7. UNDER -DISPENSER CONTAINMENT C TESTING <br />Test Method Developed By: ❑ UDC Manufacturer 'Industry Standard ❑ Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure <br />❑ Vacuum ,Hydrostatic <br />❑ Other (Sped) <br />Test Equipment Used: -T�� c_z � � _...._. <br />Equipment Resolution: <br />112-- <br />Height <br />f UDC # UDC # UDC # — <br />UDC Manufacturer: <br />— <br />UDCMaterial: UDC Depth:Height from UDC Bottom to Top <br />of Hi hest Pi in Penetration: from UDC Bottom toLowest Electrical Penetration: <br />Condition or UDC prior to <br />of UDC Tested <br />rbine shut down whennsor detects liquid (both <br />water ?shutdown <br />L <br />I <br />q Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑Yes❑No❑ NA <br />❑ Yes ❑ No❑NAand <br />response timeV4o4Ye <br />t <br />Is system programmed for fail- <br />safe shutdown?* <br />ff <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Was fail-safe verified to be <br />o erational?� <br />❑ No ❑ NA <br />❑Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />Test Start Time: <br />3 ,, <br />Initial Reading (R& <br />,gds - H. t44 <br />Test End Time: <br />C q., zx <br />Final Reading (RF): <br />Test Duration: <br />�• �j yI rtG <br />L =T S - <br />Change in Reading (RF -RI): <br />Pass/Fail Threshold or Criteria: <br />- ;� - • �� ; , <br />Test Result: <br />Was sensor removed for testing? <br />Was sensor properly replaced and <br />verified functional after testing? <br />0 Pass ❑ Fail <br />X yes ❑ No ❑ NA <br />©`I'es ❑ No ❑ NA <br />❑ Pass ❑ Fail <br />❑ Yes ❑ No ❑ NA <br />❑Yes ❑ No ❑ NA <br />❑ Pass ❑ Fail <br />❑ Pass ❑ Fail <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />❑ Yes ❑ No ❑ NA <br />Comments - (include information <br />on repairs made prior to <br />testing, and recommended <br />follow-up forfailed <br />tests) <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to Any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.