Laserfiche WebLink
I, <br /> fl �, <br /> STATE OF CALIFORNIA PETE WILSON Governor <br /> CALIFORNIA REGIONAL WATER QUALITY CONTROL BOARD— <br /> j CENTRAL VALLEY REGION <br /> 3443 ROUTIER ROAD , SUITE A : <br /> SACRAMENTO , CA 95827-3098 'n.W <br /> PHONE : 916 ) 361 -5600 Sem ESI <br /> FAX : (916 ) 361 -5686 ` <br /> +a3 �1 � <br /> APR 2 <br /> 22 April 1991 r�1Vlh �f� •pc ; -t ,, l <br /> PEh wl ( <br /> Ms . Diane Hinson <br /> San Joaquin County Public <br /> Health Services <br /> P . 0 . Box 2009 <br /> Stockton , CA 95202 <br /> REVIEW OF REPORT FOR APACHE PLASTICS - 250 EAST FREMONT STREET - STOCKTON , <br /> SAN JOAQUIN COUNTY <br /> Below is a staff review of Apache Plastics ' Report , dated August 1990 , and <br /> County comments on 27 December 1990 . The following staff comments should be <br /> incorporated with your correspondence : <br /> Neither report contained conclusions or recommendations for future work at <br /> the site . All reports in the future are to contain conclusions and <br /> // recommendations . <br /> Z . The ground water at the site is fairly deep , with the static water level <br /> about 50 feet below the mean sea level . Although wells on - site were <br /> installed with adequate screen length , they were installed with only a few <br /> feet of the ground water screened ; MW3 has already gone dry and it is <br /> possible that more wells might go dry as well . <br /> ,3 . Future wells are to be screened 10 feet above and 20 feet below the <br /> anticipated ground water level . The shallow ground water screening <br /> creates a problem in sampling for constituents that are considered <br /> " sinkers " like 1 , 2 - dichloroethane and 1 , 1 , 2 , 2-tetrachloroethane which have <br /> been detected in their ground water . Investigations are to be done by <br /> sampling deeper into the aquifer for these constituents . <br /> �F . The time between sampling and when the lab received samples was too long <br /> in certain cases . Therefore , a thorough QA/QC program for your sampling <br /> procedure is to be incorporated into the workplan . <br /> /5 . DCA and EDB were found in several wells . These constituents are associ - <br /> ated with leaded gasoline ; therefore , organic lead also is to be sampled . <br /> /6 . In the N a report , several industrial and domestic wells were <br /> identified within a one mile radius of the site . Three wells are within <br /> 700 feet of the site . Considering the proximity of these wells , it is <br /> important to know the level from which these wells are drawing water and <br /> the volume of water that is pumped . Wells 2 , 5 , and 7 on Figure 1 , near <br /> the site , must be sampled for TPHg , BTEX , DCA , EDB , and tetraethyl lead . <br /> These wells could be influencing the plume at the site . <br />