Laserfiche WebLink
July 27, 2001 <br /> Project No 2005-2050-01 <br /> page 7 <br /> . and BTEX were detected at 93 feet bgs at offsite boring CPT-11 TPHG (1 2 mg/kg) and <br /> total xylenes (11 µg/kg) were detected at 122 feet bgs at CPT-2 MTBE, ETBE, TAME, <br /> DIPE, TBA, and 1,2-DCA were not detected in any of the soil samples <br /> Groundwater analytical results (from samples collected during the CPT testing) are <br /> presented in Table 3 and Certified Analytical Reports with chain-of-custody <br /> documentation are presented in Appendix D Concentrations of TPHG, benzene, TBA, <br /> and 1,2-DCA to groundwater at select CPT locations are shown on cross sections A-A' <br /> through D-D' (Figures 7 through 10) The highest concentrations of benzene (23,000 <br /> µg/l) and toluene (26,000 µg/l) in groundwater were detected at 88 feet bgs at boring <br /> CPT-10 The highest concentration of ethylbenzene (4,300 pg/1) and total xylenes <br /> (30,100 µg/1) In groundwater were detected at 87 feet bgs at boring CPT-11 TPHG was <br /> detected at 150 mg/l at CPT-10 (88 feet bgs) and CPT-11 (87 feet bgs) in groundwater <br /> Toluene (0 94 µg/1 and total xylenes (0 90 µg/1) were detected at 132 feet bgs (the lower- <br /> most sampling interval) at boring CPT-1 TPHG and BTEX were detected at 152 feet <br /> bgs at boring CPT-8 TPHG was detected at 86 feet bgs at boring CPT-13 at a <br /> concentration dust above laboratory method detection limits The vertical extent of <br /> petroleum hydrocarbon impact to groundwater was not determined at borings CPT-1, <br /> CPT-8, and CPT-10 TBA and 1,2-DCA were detected in groundwater samples collected <br /> at bonngs CPT-1, CPT-4, CPT-8, and CPT-13 1,2-DCA was also detected to samples <br /> collected at borings CPT-5, CPT-7, CPT-10, and CPT-11 MTBE, ETBE, TAME, and <br /> DIPE were not detected in any of the groundwater samples <br /> Groundwater analytical results of samples collected from monitoring wells MWA, MW- <br /> 2, and MW-4 through MW-12 are presented In Table 1 MW-3 had an obstruction and <br /> was not sampled The highest concentrations of TPHG and BTEX were detected in the <br /> sample collected from monitoring well MW-9 TPHG and BTEX were also detected in <br /> the samples collected from monitoring well MW-1, MW-5, and MW-8 1,2-DCA was <br /> detected in the samples collected from monitoring wells MW-1 (290 µg/l), MW-2 (180 <br /> µg/1), MW-5 (40 µg/1), MW-6 (9 1 µg/1), and MW-10 (39 µg/1) TBA (70 µg11) and <br /> benzene (0 90 µg/1) were detected in the sample collected from monitonng well MW-10 <br /> MTBE was reported at a concentration of 0 66 µg/l in the sample collected from <br /> monitoring well MW-5 <br /> RECOMMENDATIONS <br /> Based on the data collected during the soil and groundwater investigation, further <br /> assessment is warranted Two additional groundwater monitoring wells should be <br /> installed north of the former UST to a depth of approximately 90 feet bgs (benzene <br /> detected at 6,700 ug/l to CPT-11) The proposed groundwater monitoring wells can be <br /> used to evaluate the lateral extent of petroleum hydrocarbon impact to groundwater in the <br /> water bearing zone encountered from approximately 85 to 90 feet bgs in the northern <br /> portion of the study area Further assessment should also be performed south and east of <br /> . CPT-10 to define the vertical extent of hydrocarbons that were detected in soil and water <br /> samples collected from CPT-8 and CPT-10 <br /> C Trolect FileslApache PlasticslReportslApache Soil&GW 072001 A doe <br /> I <br />