Laserfiche WebLink
ENVIRONMENTAL INC �}� 3330 Cameron Park Drive Ste 550 <br /> ISO- Cameron Park California 95682 <br /> (530)676-6004-Fax (530)676-6005 <br /> July 18, 2002 <br /> Q� Protect No 2005-2050-01 <br /> Ms Lon Duncan <br /> San Joaquin County Public Health Service <br /> Environmental Health Division <br /> 304 East Weber Avenue, Third Floor <br /> Stockton, California 95202 <br /> Re Second Quarter 2002 Quarterly Monitoring Report for the Fortner Apache Plastics <br /> Facility Located at 2050 East Fremont Street, Stockton, California <br /> Dear Ms Duncan <br /> On behalf of Beasley and Associates L P , Stratus Environmental, Inc (Stratus), has <br /> prepared this report documenting the results of the second quarter 2002 groundwater <br /> monitoring event conducted at the former Apache Plastics facility, located at 2050 East <br /> Fremont Street, Stockton, California (Figure 1) This report presents groundwater <br /> elevations treasured in onsite and offsite groutidwater monitoring wells, groundwater <br /> flow direction and gradient, and analytical results of groundwater samples collected <br /> during the second quarter 2002 monitoring event <br /> BACKGROUND <br /> The subject site is located in a mixed commercial/residential neighborhood in east-central <br /> Stockton and was formerly used to manufacture plastic products Topography in the area <br /> is flat, with a surface elevation of approximately 22 feet above mean sea level The <br /> property was sold to Henderson Construction, Inc in 1998 <br /> Information previously gathered during a file review at the San Joaquin County Public <br /> Health Service / Environmental Health Division (PHS/EHD) in August 1988 showed that <br /> Precision Industries, Inc observed the removal of one 1,000-gallon underground storage <br /> tank (UST) The UST was installed in 1976 in the northern portion of the facility A soil <br /> sample was collected from beneath the UST at approximately 9 feet below ground <br /> surface (bgs) Total petroleum hydrocarbons as gasoline (TPHG) and benzene were <br /> detected at concentrations of 3,400 parts per million(ppm) and 61 ppm, respectively <br /> Between August 1989 and December 1993, Western Geologic Resources, Remediation <br /> Services, Inc and BSK and Associates performed additional subsurface investigations A <br /> total of eleven soil borings were drilled and converted to seven groundwater monitoring <br /> . wells (MW-1 through MW-7), two vapor extraction wells (VEW-1 and VEW-2), and two <br /> manometers (MP-1 and MP-2) Well locations are shown on Figure 2 <br />